Cecilie Juul Mørck Offersen

Dr. Cecilie Juul Mørck Offersen

Department of Radiology, HGH, Copenhagen, Hovedstaden, Denmark
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2016 in Acta Neurochirurgica
Verified
Journal Article
Closed access
PDF file
COCecilie Juul Mørck Offersen
Cecilie Juul Mørck Offersen
JSJane Skjoeth-Rasmussen
Jane Skjoeth-Rasmussen

27 December 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
JJJacob Johansen
Jacob Johansen
COCecilie Juul Mørck Offersen
Cecilie Juul Mørck Offersen
Jonathan Frederik CarlsenJonathan Frederik Carlsen
Jonathan Frederik Carlsen
SISilvia Ingala
Silvia Ingala
AHAdam E. Hansen
Adam E. Hansen
APAkshay Pai
Akshay Pai
DWI/FLAIR mismatch assessment for ischemic stroke patients shows promising results in determining if patients are eligible for recombinant tissue-type plasminogen activator (r-tPA) treatment. However, the mismatch criteria suffer from two major issues: binary classification of a non-binary problem and the subjectiveness of the assessor. In this article, we present a simple automatic method for segmenting stroke-related parenchymal hyperintensities on FLAIR, allowing for an automatic and continuous DWI/FLAIR mismatch assessment. We further show that our method’s segmentations have comparable inter-rater agreement (DICE 0.820, SD 0.12) compared to that of two neuro-radiologists (DICE 0.856, SD 0.07), that our method appears robust to hyper-parameter choices (suggesting good generalizability), and lastly, that our methods continuous DWI/FLAIR mismatch assessment correlates to mismatch assessments made for a cohort of wake-up stroke patients at hospital submission. The proposed method shows promising results in automating the segmentation of parenchymal hyperintensity within ischemic stroke lesions and could help reduce inter-observer variability of DWI/FLAIR mismatch assessment performed in clinical environments as well as offer a continuous assessment instead of the current binary one.

19 June 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
COCecilie Juul Mørck Offersen
Cecilie Juul Mørck Offersen
JSJens Sørensen
Jens Sørensen
KSKaining Sheng
Kaining Sheng
Jonathan Frederik CarlsenJonathan Frederik Carlsen
Jonathan Frederik Carlsen
ALAnnika Reynberg Langkilde
Annika Reynberg Langkilde
Michael Bachmann NielsenMichael Bachmann Nielsen
Michael Bachmann Nielsen
We conducted this Systematic Review to create an overview of the currently existing Artificial Intelligence (AI) methods for Magnetic Resonance Diffusion-Weighted Imaging (DWI)/Fluid-Attenuated Inversion Recovery (FLAIR)—mismatch assessment and to determine how well DWI/FLAIR mismatch algorithms perform compared to domain experts. We searched PubMed Medline, Ovid Embase, Scopus, Web of Science, Cochrane, and IEEE Xplore literature databases for relevant studies published between 1 January 2017 and 20 November 2022, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We assessed the included studies using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Five studies fit the scope of this review. The area under the curve ranged from 0.74 to 0.90. The sensitivity and specificity ranged from 0.70 to 0.85 and 0.74 to 0.84, respectively. Negative predictive value, positive predictive value, and accuracy ranged from 0.55 to 0.82, 0.74 to 0.91, and 0.73 to 0.83, respectively. In a binary classification of ±4.5 h from stroke onset, the surveyed AI methods performed equivalent to or even better than domain experts. However, using the relation between time since stroke onset (TSS) and increasing visibility of FLAIR hyperintensity lesions is not recommended for the determination of TSS within the first 4.5 h. An AI algorithm on DWI/FLAIR mismatch assessment focused on treatment eligibility, outcome prediction, and consideration of patient-specific data could potentially increase the proportion of stroke patients with unknown onset who could be treated with thrombolysis.

3 August 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
KSKaining Sheng
Kaining Sheng
COCecilie Juul Mørck Offersen
Cecilie Juul Mørck Offersen
JMJon Middleton
Jon Middleton
Jonathan Frederik CarlsenJonathan Frederik Carlsen
Jonathan Frederik Carlsen
Thomas Clement TruelsenThomas Clement Truelsen
Thomas Clement Truelsen
Michael Bachmann NielsenMichael Bachmann Nielsen
Michael Bachmann Nielsen
We conducted a systematic review of the current status of machine learning (ML) algorithms’ ability to identify multiple brain diseases, and we evaluated their applicability for improving existing scan acquisition and interpretation workflows. PubMed Medline, Ovid Embase, Scopus, Web of Science, and IEEE Xplore literature databases were searched for relevant studies published between January 2017 and February 2022. The quality of the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. The applicability of ML algorithms for successful workflow improvement was qualitatively assessed based on the satisfaction of three clinical requirements. A total of 19 studies were included for qualitative synthesis. The included studies performed classification tasks (n = 12) and segmentation tasks (n = 7). For classification algorithms, the area under the receiver operating characteristic curve (AUC) ranged from 0.765 to 0.997, while accuracy, sensitivity, and specificity ranged from 80% to 100%, 72% to 100%, and 65% to 100%, respectively. For segmentation algorithms, the Dice coefficient ranged from 0.300 to 0.912. No studies satisfied all clinical requirements for successful workflow improvements due to key limitations pertaining to the study’s design, study data, reference standards, and performance reporting. Standardized reporting guidelines tailored for ML in radiology, prospective study designs, and multi-site testing could help alleviate this.

26 May 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
Sif Binder LarsenSif Binder Larsen
Sif Binder Larsen
COCecilie Juul Mørck Offersen
Cecilie Juul Mørck Offersen
EDEva Dyrberg
Eva Dyrberg
JJJens Kurt Johansen
Jens Kurt Johansen
NLNaja Bjørslev Lange
Naja Bjørslev Lange
STSøren Tobias Torp-Pedersen
Søren Tobias Torp-Pedersen
Background: Intermetatarsal bursitis (IMB) is emerging as a diagnostic consideration for patients with forefoot pain. However, few investigations have been conducted into the incidence of IMB among patients with forefoot pain. The symptoms of IMB are described as mimicking those of Morton’s neuroma (MN). Currently, the best method to differentiate between MN and IMB is radiological evaluation. Based on this, the aim of this study was to investigate the incidence of IMB and MN in a prospective cohort of patients with intermetatarsal pain diagnosed with radiological evaluation and compared to a control group. Methods: This study included 26 patients and 13 controls. All participants underwent magnetic resonance imaging (MRI) and ultrasound (US) of one forefoot. Results: Among the 26 patients, 5 (19.2%) had MN and 14 (53.8%) had IMB on MRI compared to US, with which 25 (96.2%) cases of IMB and 0 with MN were identified. In the control group, both modalities found asymptomatic web space pathology in four cases (30.8%), and US identified normal intermetatarsal bursas in five cases. Additionally, our results indicate that MN patients have more severe pain and a longer history of pain compared to IMB patients. Conclusions: Based on our MRI results, we conclude that IMB is frequent in patients with intermetatarsal pain. Differentiation between MN and IMB with US is complex and should be performed with caution and an understanding of both conditions. Normal intermetatarsal bursas are also visible on US as hypoechoic but non-expansive masses.

7 August 2025 in European Journal of Radiology Artificial Intelligence
Verified
Journal Article
Open access
COCecilie Juul Mørck Offersen
Cecilie Juul Mørck Offersen
JJJacob Johansen
Jacob Johansen
ABAndreas Hjelm Brandt
Andreas Hjelm Brandt
TTThomas Clement Truelsen
Thomas Clement Truelsen
SDSune Darkner
Sune Darkner
JCJonathan Frederik Carlsen
Jonathan Frederik Carlsen