Chun Wei Huang

Prof. Chun Wei Huang

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
SHShih-Hsien Hsu
Shih-Hsien Hsu
Fu Ming TzuFu Ming Tzu
Fu Ming Tzu
YCYi-Dong Chen
Yi-Dong Chen
CHChun Wei Huang
Chun Wei Huang
This paper addresses the growing concern over air pollutant emissions (NOx, SOx, PM, CO2) from ocean-going vessels in harbor areas and the role of Onshore Power Supply (OPS) systems in mitigating these emissions during vessel berthing. However, the slow progress in global shore power facilities is attributed to safety- and specification-related concerns. Our study conducts a comprehensive analysis, comparing international shore power regulations, with a specific focus on the IEC/IEEE 80005-1 standard and guidelines from various ship classification societies. We introduce checklists, scoring tables, and spider diagrams to evaluate the regulatory content, highlighting the strengths and weaknesses of each approach. Furthermore, this paper emphasizes the significance of a well-defined operational process for high-voltage shore connection (HVSC) to ensure the safety of OPS operations. We present process diagrams for key operational stages, based on IEC/IEEE 80005-1 specifications and evaluation criteria. The ultimate goal of this research is to drive the global adoption of shore power and foster the establishment of shore power facilities worldwide. This aligns with the broader environmental protection objectives of achieving cleaner ports and reducing emissions for a sustainable future.

15 November 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TWTsai-Fu Wu
Tsai-Fu Wu
CHChun Wei Huang
Chun Wei Huang
Tzu-Chieh ChouTzu-Chieh Chou
Tzu-Chieh Chou
KSKai Sun
Kai Sun

29 January 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
TWTsai-Fu Wu
Tsai-Fu Wu
Tzu-Chieh ChouTzu-Chieh Chou
Tzu-Chieh Chou
CHChun Wei Huang
Chun Wei Huang
KSKai Sun
Kai Sun
This paper presents bidirectional grid-connected modular multilevel converters (MMC) with direct digital control and division-summation processes to achieve power-injection and rectification functions. A direct digital control is developed to track current references, regulate dc-bus voltage and cell voltage, and balance the upper and lower dc-bus voltages. It can accommodate wide filter-inductance variation and take care of source voltage harmonics to achieve tight current tracking and low distortion output current. Based on the power-balance principle, the commands of arm currents can be determined directly. In this paper, the MMC configuration is introduced first, and then the control laws for current tracking and voltage regulation are derived in detail. Experimental and simulated results obtained from two 50 kW MMCs operated in power-injection and rectification modes have verified the analysis and discussion.

24 January 2026 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Open access
CHChun Wei Huang
Chun Wei Huang
SHS.-H. Hsu
S.-H. Hsu
Tzu-Chieh ChouTzu-Chieh Chou
Tzu-Chieh Chou
PLP.-H. Lee
P.-H. Lee

19 December 2025 in IEEE Access
Verified
Journal Article
Open access
Tzu-Chieh ChouTzu-Chieh Chou
Tzu-Chieh Chou
CHChun Wei Huang
Chun Wei Huang
CHChien-Chih Hung
Chien-Chih Hung
This paper presents implementation of direct digital control in modular multilevel converters (MMCs) for hot-swap capability via distributed module controllers, which in turn can achieve a fault-tolerance mechanism. Adopting the module distributed controllers is to realize an extension of cell-module (CM) number, increase MMC stability and reliability, and simplify the complexity of fault-tolerance mechanism. The proposed direct digital control can take into account wide filter-inductance variation and source-voltage harmonics, and help achieve seamless hot-swap features with low distortion on output currents and less interference to grid voltages. In this paper, the module-distributed controllers are introduced first, and then the fault-tolerance mechanism for either CM unplugging or plugging is presented in detail. Experimental and simulated results obtained from an MMC operated in power-injection and with a hot-swap feature have verified the analysis and discussion.

14 October 2025 in Electronics
Verified
Journal Article
Open access
PDF file
Tzu-Chieh ChouTzu-Chieh Chou
Tzu-Chieh Chou
PLPin-Sheng Lee
Pin-Sheng Lee
CCChi-Yuan Chuang
Chi-Yuan Chuang
CHChun Wei Huang
Chun Wei Huang
This paper presents a control delay compensation method for an LLCL-type active power filter (APF), aimed at improving performance in digital control systems. The proposed strategy is directly integrated into the inner-loop current controller, requiring no additional compensation modules, predictor structures, or capacitor current feedback, which simplifies the control structure and increases flexibility. The method uses real-time internal state responses of the controller to actively compensate for the phase lag caused by digital control delay, effectively maintaining current control accuracy and overall system dynamic stability. Simulation studies based on a 5.5 kW APF system are conducted to verify the effectiveness of the approach. The results show improved current tracking accuracy, stable dynamic behavior under various load conditions. The simulation-based results indicate the potential of the proposed method for improving control accuracy and stability in digitally controlled APF systems. Moreover, very few studies have addressed control delay compensation specifically for LLCL-based APF systems, making this work a valuable contribution to the field.