Corrado Cescon

Prof. Corrado Cescon

SUPSI
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2002 in Biological Cybernetics
Verified
Journal Article
Closed access
PDF file
DFDario Farina
Dario Farina
CCCorrado Cescon
Corrado Cescon
RMRoberto Merletti
Roberto Merletti

1 January 2010 in Critical Reviews in Biomedical Engineering
Verified
Journal Article
Closed access
RMRoberto Merletti
Roberto Merletti
ABAlberto Botter
Alberto Botter
CCCorrado Cescon
Corrado Cescon
MMMarco A. Minetto
Marco A. Minetto
TVTaian Vieira
Taian Vieira
This article is the second part of a larger review work that has been structured in three parts. The three parts concern a) advances in surface EMG detection and processing techniques, b) recent progress in surface EMG clinical research applications, and c) myoelectric control in neurorehabilitation. This second part concerns state of the art applications of surface EMG techniques to a) the external anal sphincter in relation to episiotomy and incontinence; b) the assessment of postural control mechanisms; c) exercise physiology, electrical stimulation and muscle cramps; and d) ergonomics and work-related neuromuscular disorders. The material is presented with an effort to fill gaps left by previous reviews and identify areas open for future research.

1 October 2009 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Closed access
Luca MesinLuca Mesin
Luca Mesin
CCCorrado Cescon
Corrado Cescon
MGMARCO GAZZONI
MARCO GAZZONI
RMRoberto Merletti
Roberto Merletti
Alberto RainoldiAlberto Rainoldi
Alberto Rainoldi

1 January 2001 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
DFD. Farina
D. Farina
CCCorrado Cescon
Corrado Cescon
New recording techniques for detecting surface electromyographic (EMG) signals based on concentric-ring electrodes are proposed in this paper. A theoretical study of the two-dimensional (2-D) spatial transfer function of these recording systems is developed both in case of rings with a physical dimension and in case of line rings. Design criteria for the proposed systems are presented in relation to spatial selectivity. It is shown that, given the radii of the rings, the weights of the spatial filter can be selected in order to improve the rejection of low spatial frequencies, thus increasing spatial selectivity. The theoretical transfer functions of concentric systems are obtained and compared with those of other detection systems. Signals detected with the ring electrodes and with traditional one-dimensional and 2-D systems are compared. The concentric-ring systems show higher spatial selectivity with respect to the traditional detection systems and reduce the problem of electrode location since they are invariant to rotations. The results shown are very promising for the noninvasive detection of single motor unit (MU) activities and decomposition of the surface EMG signal into the constituent MU action potential trains.

1 July 2008 in Journal of Neurophysiology
Verified
Journal Article
Closed access
PDF file
DFDario Farina
Dario Farina
CCCorrado Cescon
Corrado Cescon
FNFrancesco Negro
Francesco Negro
RERoger M. Enoka
Roger M. Enoka
The study presents analytical, simulation, and experimental analyses of amplitude cancellation of motor-unit action potentials (APs) in the interference electromyogram (EMG) and its relation to the size of the spike-triggered average (STA) EMG. The amount of cancellation of motor-unit APs decreases monotonically as a function of the ratio between the root mean square (RMS) of the motor-unit AP and the RMS of the interference EMG signal. The theoretical derivation of this association indicates a method to measure cancellation in individual motor units by STA of the interference and squared EMGs. The theoretical relation was examined in both simulated EMG signals generated by populations of 200 motor units and experimental recordings of 492 and 184 motor-unit APs in the vastus medialis and abductor digiti minimi muscles, respectively. Although the theoretical relation predicted ( R2 = 0.95; P < 0.001) the amount of cancellation in the simulated EMGs, the presence of motor-unit synchronization decreased the strength of the association for small APs. The decrease in size of the STA obtained from the squared EMG relative to that extracted from the interference EMG was predicted by the experimental measure of cancellation ( R2 = 0.65; P < 0.001, for vastus medialis; R2 = 0.26; P < 0.05, for abductor digiti minimi). The results indicate that cancellation of APs in the interference EMG can be analytically predicted and experimentally measured with STA from the discharge times of the motor units into the surface EMG.

1 March 2004 in Digestion
Verified
Journal Article
Closed access
RMRoberto Merletti
Roberto Merletti
ABA. Bottin
A. Bottin
CCCorrado Cescon
Corrado Cescon
DFD. Farina
D. Farina
MGMARCO GAZZONI
MARCO GAZZONI
PEP. Enck
P. Enck
Background/Aims: This work focuses on recording, processing and interpretation of multichannel surface EMG detected from the external anal sphincter muscle. The aim is to describe the information that can be extracted from signals recorded with such a technique. Methods: The recording of many signals from different locations on a muscle allows the extraction of additional information on muscle physiology and anatomy with respect to that obtained by classic bipolar recordings. Multichannel EMG methods have been recently developed for the assessment of the external anal sphincter. An anal probe was used in this study to record signals at different depths within the anal canal during contractions at different effort levels. The plug is 150 mm in length and 14 mm in diameter, holding a circumferential array of 16 equally spaced silver bar electrodes, located at a distance of 20 mm from the probe tip and aligned with the probe axis. Results: Information about localization of the innervation zone, fiber length, EMG amplitude, muscle fiber conduction velocity and single motor unit analysis can be obtained from the signals recorded with the circumferential array by means of innovative signal processing techniques. Conclusions: The type of information extracted from multichannel surface EMG signals cannot be obtained with other currently available techniques. The technological innovation described in this work is promising for a further insight into the investigation of pelvic floor pathologies and rehabilitation treatments.