David Lowndes Williams

Dr. David Lowndes Williams

The University of Manchester
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2021 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
EMEdward J. Mausolf
Edward J. Mausolf
EJErik Johnstone
Erik Johnstone
NHNatalia Mayordomo Herranz
Natalia Mayordomo Herranz
DWDavid Lowndes Williams
David Lowndes Williams
EGEugene Yao Z. Guan
Eugene Yao Z. Guan
CGCharles Gary
Charles Gary
Presented are the results of 99mTc and 101Tc production via neutron irradiation of natural isotopic molybdenum (Mo) with epithermal/resonance neutrons. Neutrons were produced using a deuterium-deuterium (D-D) neutron generator with an output of 2 × 1010 n/s. The separation of Tc from an irradiated source of bulk, low-specific activity (LSA) Mo on activated carbon (AC) was demonstrated. The yields of 99mTc and 101Tc, together with their potential use in medical single-photon emission computed tomography (SPECT) procedures, have been evaluated from the perspective of commercial production, with a patient dose consisting of 740 MBq (20 mCi) of 99mTc. The number of neutron generators to meet the annual 40,000,000 world-wide procedures is estimated for each imaging modality: 99mTc versus 101Tc, D-D versus deuterium-tritium (D-T) neutron generator system outputs, and whether or not natural molybdenum or enriched targets are used for production. The financial implications for neutron generator production of these isotopes is also presented. The use of 101Tc as a diagnostic, therapeutic, and/or theranostic isotope for use in medical applications is proposed and compared to known commercial nuclear diagnostic and therapeutic isotopes.

26 November 2020 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
DWDavid Lowndes Williams
David Lowndes Williams
CBCraig M. Brown
Craig M. Brown
DTDavid Tong
David Tong
ASAlexander Sulyman
Alexander Sulyman
CGCharles Gary
Charles Gary
Resolution measurements were made using 14.1 MeV neutrons from a high-yield, portable DT neutron generator and a neutron camera based on a scintillation screen viewed by a digital camera. Resolution measurements were made using a custom-built, plastic, USAF-1951 resolution chart, of dimensions 125 × 98 × 25.4 mm3, and by calculating the modulation transfer function from the edge-spread function from edges of plastic and steel objects. A portable neutron generator with a yield of 3 × 109 n/s (DT) and a spot size of 1.5 mm was used to irradiate the object with neutrons for 10 min. The neutron camera, based on a 6LiF/ZnS:Cu-doped polypropylene scintillation screen and digital camera was placed at a distance of 140 cm, and produced an image with a spatial resolution of 0.35 cycles per millimeter.

19 April 2013 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
JVJ. H. Vainionpaa
J. H. Vainionpaa
JHJ. L. Harris
J. L. Harris
MPM. A. Piestrup
M. A. Piestrup
CGC. K. Gary
C. K. Gary
DWDavid Lowndes Williams
David Lowndes Williams
GJG. Jones
G. Jones
A product line of high yield neutron generators has been developed at Adelphi technology inc. The generators use the D-D fusion reaction and are driven by an ion beam supplied by a microwave ion source. Yields of up to 5 × 109 n/s have been achieved, which are comparable to those obtained using the more efficient D-T reaction. The microwave-driven plasma uses the electron cyclotron resonance (ECR) to produce a high plasma density for high current and high atomic ion species. These generators have an actively pumped vacuum system that allows operation at reduced pressure in the target chamber, increasing the overall system reliability. Since no radioactive tritium is used, the generators can be easily serviced, and components can be easily replaced, providing essentially an unlimited lifetime. Fast neutron source size can be adjusted by selecting the aperture and target geometries according to customer specifications. Pulsed and continuous operation has been demonstrated. Minimum pulse lengths of 50 μs have been achieved. Since the generators are easily serviceable, they offer a long lifetime neutron generator for laboratories and commercial systems requiring continuous operation. Several of the generators have been enclosed in radiation shielding/moderator structures designed for customer specifications. These generators have been proven to be useful for prompt gamma neutron activation analysis (PGNAA), neutron activation analysis (NAA) and fast neutron radiography. Thus these generators make excellent fast, epithermal and thermal neutron sources for laboratories and industrial applications that require neutrons with safe operation, small footprint, low cost and small regulatory burden.

1 March 1998 in Optics Communications
Verified
Journal Article
Closed access
DWDavid Lowndes Williams
David Lowndes Williams
DWDavid P. West
David P. West
TKTerence A. King
Terence A. King

1 September 1995 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
DWDavid Lowndes Williams
David Lowndes Williams
FRF.H. Read
F.H. Read
NBN.J. Bowring
N.J. Bowring

1 January 2010 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JCJay Theodore (Ted) Cremer
Jay Theodore (Ted) Cremer
DWDavid Lowndes Williams
David Lowndes Williams
MFM. J. Fuller
M. J. Fuller
CGC. K. Gary
C. K. Gary
MPM. A. Piestrup
M. A. Piestrup
RWR. B. Walker
R. B. Walker
A novel periodic magnetic field (PMF) optic is shown to act as a prism, lens, and polarizer for neutrons and particles with a magnetic dipole moment. The PMF has a two-dimensional field in the axial direction of neutron propagation. The PMF alternating magnetic field polarity provides strong gradients that cause separation of neutrons by wavelength axially and by spin state transversely. The spin-up neutrons exit the PMF with their magnetic spins aligned parallel to the PMF magnetic field, and are deflected upward and line focus at a fixed vertical height, proportional to the PMF period, at a downstream focal distance that increases with neutron energy. The PMF has no attenuation by absorption or scatter, as with material prisms or crystal monochromators. Embodiments of the PMF include neutron spectrometer or monochromator, and applications include neutron small angle scattering, crystallography, residual stress analysis, cross section measurements, and reflectometry. Presented are theory, experimental results, computer simulation, applications of the PMF, and comparison of its performance to Stern–Gerlach gradient devices and compound material and magnetic refractive prisms.