Resolution measurements were made using 14.1 MeV neutrons from a high-yield, portable DT neutron generator and a neutron camera based on a scintillation screen viewed by a digital camera. Resolution measurements were made using a custom-built, plastic, USAF-1951 resolution chart, of dimensions 125 × 98 × 25.4 mm3, and by calculating the modulation transfer function from the edge-spread function from edges of plastic and steel objects. A portable neutron generator with a yield of 3 × 109 n/s (DT) and a spot size of 1.5 mm was used to irradiate the object with neutrons for 10 min. The neutron camera, based on a 6LiF/ZnS:Cu-doped polypropylene scintillation screen and digital camera was placed at a distance of 140 cm, and produced an image with a spatial resolution of 0.35 cycles per millimeter.
Presented are the results of 99mTc and 101Tc production via neutron irradiation of natural isotopic molybdenum (Mo) with epithermal/resonance neutrons. Neutrons were produced using a deuterium-deuterium (D-D) neutron generator with an output of 2 × 1010 n/s. The separation of Tc from an irradiated source of bulk, low-specific activity (LSA) Mo on activated carbon (AC) was demonstrated. The yields of 99mTc and 101Tc, together with their potential use in medical single-photon emission computed tomography (SPECT) procedures, have been evaluated from the perspective of commercial production, with a patient dose consisting of 740 MBq (20 mCi) of 99mTc. The number of neutron generators to meet the annual 40,000,000 world-wide procedures is estimated for each imaging modality: 99mTc versus 101Tc, D-D versus deuterium-tritium (D-T) neutron generator system outputs, and whether or not natural molybdenum or enriched targets are used for production. The financial implications for neutron generator production of these isotopes is also presented. The use of 101Tc as a diagnostic, therapeutic, and/or theranostic isotope for use in medical applications is proposed and compared to known commercial nuclear diagnostic and therapeutic isotopes.
Channeling radiation is a source of intense, tunable, quasimonochromatic x rays produced by electrons traveling along a direction of symmetry through a crystal. We analyze the effect of the channeling source crystal, through both its composition and lattice structure, on the number of photons emitted per electron, the linewidths of the radiation, and the maximum sustainable currents to identify the crystal which will yield the most photons in a bandwidth of less than 10% full width at half maximum (FWHM). Although high atomic number (Z) crystals produce a greater number of photons per electron, given their poor thermal properties these crystals cannot sustain as high average currents as lower Z crystals. The linewidths of the channeling radiation emitted from high Z crystals are as large as 50% FWHM, and electrons are dechanneled more quickly in these crystals, limiting their use as a quasimonochromatic x-ray source. Given its exceptional thermal conductivity and narrow linewidths, diamond is the optimal source crystal for the production of intense, quasimonochromatic x rays using channeling radiation.
1 October 2004 in Review of Scientific Instruments
We present diagnostic images taken of an -pinch plasma x-ray source driven by the XP pulser at Cornell University using an x-ray bubble compound refractive lens. The lens consists of a inside diameter glass capillary that contains about biconcave microlenses formed by a string of bubbles in epoxy. A precise system for lens alignment with of 3–5 arcmin accuracy is described. X-ray images of four-wire pinches were obtained with a spatial resolution of approximately .
The authors present x-ray images of grid meshes and biological material obtained using a microspot x-ray tube with a multilayer optic and a 92-element parabolic compound refractive lens (CRL) made of a plastic containing only hydrogen and carbon. Images obtained using this apparatus are compared with those using an area source with a spherical lens and a spherical lens with multilayer condenser. The authors found the best image quality using the multilayer condenser with a parabolic lens, compared to images with a spherical lens and without the multilayer optics. The resolution was measured using a 155-element parabolic CRL and a multilayer condenser with the microspot tube. The experiment demonstrates about resolution.
We present a system for diagnostic imaging of x-ray sources using a compound refractive lens. Such a system can be built at a low cost, yet image at resolutions of 2 μm or better. The essential components of the system are the source to be imaged, a compound refractive lens and imaging detector (either electronic or film). In addition, spatial and spectral filters can be added to improve resolution and a laser alignment system can be used to rapidly align the source, lens and camera.