The arbitrary placement of sensors in concrete structures measures a considerable amount of unnecessary data. Optimal sensor placement methods are used to provide informative data with the least cost and maximum efficiency. In this study, a robust optimal sensor placement framework that combines an optimization-based algorithm, the simulated annealing (SA) algorithm, and the ensemble Kalman filter (EnKF) are presented for structural health monitoring and system identification. The SA algorithm randomly generates an initial population of sensor locations, while the framework undergoes a minimization process. The objective function used is the difference between the actual measured data and their corresponding EnKF predicted values. A comparative analysis between the genetic algorithm–ensemble Kalman filter (GA-EnKF) and the simulated annealing–ensemble Kalman filter (SA-EnKF) approaches is presented. The performance and computational burden of both algorithms, which converge to the best sensor locations for damage detection purposes, are tested on a 10-story building subjected to a seismic excitation. The results are compared to the optimal sensor locations of the brute-force search methodology. The GA-EnKF outperforms the SA-EnKF in terms of accuracy in converging to the optimal results, yet the computational cost of the SA-EnKF is considerably lower.
This study aimed to optimize the performance of pervious concrete (PC) while promoting sustainability using recycled concrete aggregates (RCAs), styrene butadiene rubber (SBR) waste, and silica fume (SF). The mixtures were developed using the Taguchi approach with four mix design factors, each at three levels: the water-to-binder ratio (w/b), RCA replacement percentage by weight of natural aggregates, the cement substitution rate with SF, and the SBR addition rate by binder mass. Thus, a total of nine mixes were prepared and tested for density, porosity, permeability, compressive strength, splitting tensile strength, abrasion resistance, and resistance to freezing and thawing. The results revealed that incorporating RCA and SBR decreased density and compressive strength but increased porosity and permeability. The performance of PC enhanced with SF addition and reduced w/b. TOPSIS was then employed to find the optimum mixture design proportions by considering multiple performance criteria. The results indicated that a high-performing sustainable PC mixture, with enhanced strength and durability characteristics, was formulated with a w/b ratio of 0.30, 25% RCA, 5% SF replacement, and 4% SBR addition.
16 January 2021 in International Journal of Civil Engineering
This paper assesses the feasibility of metakaolin (MK)-based geopolymer (GP) composite as an environmentally friendly substitute for cement-based composite in repair applications. The Taguchi orthogonal array method was used to find the optimum GP mix in terms of mechanical properties and adhesion to concrete substrates. Four key parameters, each with three levels, are investigated including the alkaline activator-to-MK ratio (A/M: 1, 1.2, 1.4), the sodium silicate-to-sodium hydroxide ratio (S/H: 2.0, 2.5, 3.0), sodium hydroxide (SH) molarity (12, 14, 16), and curing temperature (30, 45, 60 °C). The evaluated properties include flowability, compressive strength, splitting tensile strength, flexural strength, ultrasonic pulse velocity, and bond strength under various interface configurations. Experimental results demonstrated that the performance of MK-based GP composite was primarily governed by the A/M ratio and sodium hydroxide molarity. The Taguchi optimization method revealed that the mix design featuring A/M of 1.4, SS/SH of 2, 16 M sodium hydroxide, and curing at 60 °C yielded notable improvements in compressive and bond strengths compared to conventional cement-based composites.
Fibers are widely used in concrete structures to control crack propagation and widening due to sustained or impact loads. Nevertheless, the concrete’s mechanical and structural properties are strongly affected by the fibers’ spatial distribution and clumping tendency within the mass material. The main objective of this paper is to assess the efficiency of stochastic finite element modeling to predict the shear strength properties of fiber-reinforced concrete (FRC) beams without stirrups, as tested by four-point loading. Polypropylene and polyvinyl alcohol micro-filament fibers are investigated in this experimental program at relatively high rates, varying from 0.5% to 1% by volume. A stochastic sensitivity analysis is performed using both random fields and random variables to determine the effect of fiber additions on the concrete’s mechanical properties (i.e., splitting tensile strength and modulus of elasticity) including the beam cracking patterns, ductility, mid-span deflection, and ultimate load. Such data could be of interest to civil engineers and structural designers to reduce the effort and resources needed to assess the FRC strength variability and failure behaviors of structural members.
27 January 2026 in Innovative Infrastructure Solutions