Daniel Lisardo González Díaz

Mr. Daniel Lisardo González Díaz

teaching assistant, Miguel de Cervantes European University, Valladolid, Castille-Leon, Spain
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Daniel Lisardo González DíazDaniel Lisardo González Díaz
Daniel Lisardo González Díaz
SLSusana López-Ortiz
Susana López-Ortiz
IJIrati Jauregui-Fajardo
Irati Jauregui-Fajardo
Jose Pinto-FragaJose Pinto-Fraga
Jose Pinto-Fraga
CGCelia García-Chico
Celia García-Chico
Sergio Maroto-IzquierdoSergio Maroto-Izquierdo
Sergio Maroto-Izquierdo
Multiple sclerosis (MS) is a neurodegenerative disease that often leads to severe disability. Although exercise, particularly strength training, improves health outcomes in MS, no standardized, reliable tool exists for functional assessment to inform tailored exercise prescriptions and patients’ categorization. This study aimed to validate the reliability of the MScope battery, a comprehensive tool incorporating structural, functional, and neuromuscular assessments to objectively evaluate patients with MS. A reproducibility study was conducted with 40 MS patients who completed the MScope battery twice, 72 h apart. Tests included structural (muscle thickness of the vastus lateralis and rectus femoris), functional (sit-to-stand, timed up-and-go, 10 m and six-minute walking test), and neuromuscular tests (isometric strength during the squat and leg extension exercises and handgrip strength). Intraclass correlation coefficients (ICCs), Bland–Altman plots, and the coefficient of variation (CV) were used to evaluate intra- and inter-day reliability. The MScope battery showed high intra- and inter-day reliability, with ICC values ranging from 0.79 to 0.99. Muscle thickness measurements, along with handgrip strength, demonstrated excellent reliability (ICC > 0.9, CV < 5%). Functional tests, including the timed up-and-go, 10 m walk, and sit-to-stand variations, maintained consistent scores (ICC > 0.85, CV < 10%). The six-minute walking test exhibited excellent inter-day reliability (ICC = 0.94, CV < 4%). Neuromuscular assessments showed strong reliability with minor day-to-day variability (ICC = 0.75–0.95, CV < 8%). The battery’s overall consistency supports its use as a reliable tool for assessing functional status in MS patients.