Corrosion is a phenomenon that significantly impacts the durability of reinforced concrete (RC) structures, particularly in highly corrosive environments like coastal regions. The existing numerical modelling often relies on complex approaches that are impractical for structural assessment. For this reason, this study proposes a simplified numerical modelling approach to simulate the cyclic behaviour of existing RC framed structures with corrosion levels (η) below 25%. The proposed modelling employs concentrated plasticity hinges for beams and fiber sections for columns, incorporating corrosion-induced degradation through modified backbone curves and material properties based on the corrosion level of the structural element. The modelling approach was validated against experimental results from the literature; the proposed model adequately captures hysteretic energy, lateral load, and deformation capacities, with maximum errors of 11% for maximum lateral load, 12% for ultimate load, and 33% for dissipated energy in RC frames. For isolated columns, the errors were 11, 12, and 22%, respectively. In addition, a maximum difference of 7% was found in the lateral load capacity of the corroded frames associated with the Life Safety limit state. Finally, it was concluded that the proposed methodology is suitable for representing the cyclic behaviour of corroded RC columns and frames and provides engineers with a tool to evaluate the behaviour of corroded structures without resorting to complex models.
Frame buildings are prone to cracking because of their deformation by normal and extreme events such as temperature and earthquakes. Even though the crack widths are limited in the structural design, a cracked cover reduces the corrosion protection of reinforcing steel. Therefore, the load capacity of structures can be compromised prematurely. This paper aims to evaluate the flexo-compressive strength of deteriorated reinforced concrete (RC) elements in the corrosion process. To that end, a methodology to calculate the residual strength capacity was proposed, considering the influences of crack widths and cover width on the corrosion level—structure age relation of RC elements. The strength deteriorations caused by the concrete cracking and the steel corrosion were incorporated according to structure age. The residual strength was studied using parametric analyses, whose variables were the crack width, the cover width, the rebar diameter, and the structure age. The results showed that the cracked frame elements reduced their serviceability life by up to 62%, although their crack widths were within range recommended by the design codes (lesser than 0.30 mm). In 25 years, the corrosion effects reduce the element strength by up to 44%. This is due to the corrosion protection provided by the cracked cover becomes insignificant, reducing the initiation time. Thus, considering the corrosion deterioration can prevent strength overestimations up to 1.46 times. Additionally, according to their current state, the proposed methodology provides a practical estimation of flexo-compressive strength in corroded RC elements.
Corrosion of reinforcing steel is a key cause of deterioration in reinforced concrete (RC) structures exposed to coastal environments with chloride presence. The loss of reinforcing steel cross-sectional area, cracking of the concrete cover, and reduction in confinement progressively decrease both strength and ductility of structural elements. This study provides a reproducible, open-access dataset, compiling input parameters and numerical results of the cyclic behaviour of isolated RC columns and RC frames, specifically addressing their nonlinear cyclic response under moderate corrosion (η < 25%), as well as in the non-corroded (baseline) conditions, generated through conventional nonlinear modelling. In terms of modelling, the methodology applies fibre-section modelling for columns and concentrated plastic hinges for beams. Furthermore, the corrosion effects are incorporated by reducing the steel area and ultimate strain, while also accounting for the decrease in compressive strength of the cracked concrete cover. Therefore, the cyclic response is represented by a Pivot-type hysteretic model. It is worth noting that the dataset provides model input information, such as material stress–strain relationships and backbone curves reflecting corrosion-induced deterioration. It also includes structural outputs, such as force–displacement relationships, and envelopes of quasi-static hysteretic cycles for the analyzed columns and frames. Overall, the dataset facilitates the calibration and validation of numerical models for RC structures affected by corrosion. In conclusion, the contribution enhances the reliability of computational simulations and supports the development of predictive tools for structural performance under degradation scenarios.
This paper presents a dataset developed to characterize the citizens’ perceptions of urban resilience applied to the Veracruz—Boca del Río Metropolitan Area (VBMA) in Mexico. The data were obtained by conducting online surveys, which were administered to a total of 147 subjects, including 89 from the municipality of Veracruz, 35 from Boca del Río, 15 from Medellín de Bravo, and 8 from Alvarado, with ages ranging from 16 years to over 61 years. The survey was designed to estimate the population’s perception of the Urban Resilience Index (URI) and the Urban Resilience Profile (URP). It was developed derived from a methodology based on IMPLAN and enriched with questionnaires from Villada and SEDATU, resulting in a final questionnaire comprising 10 axes, 33 indicators, and 156 variables. A novel contribution was implemented as a significant study case, which uses the dataset to estimate the URI and URP to the VBMA applying the Entropy Method, considering three criteria: age, gender, and municipality. Here, citizens’ perceptions about urban resilience have been estimated in an URI equal to 0.4571, resulting in a moderate level of resilience. Moreover, this perception could be improved by conducting a full-scale survey with substantial financial investment.