Diogo Ricardo

Prof. Dr. Diogo Ricardo

Escola Superior de Tecnologia da Saúde de Lisboa, Lisbon, Lisboa, Portugal
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2021 in Children
Verified
Journal Article
Open access
PDF file
DRDiogo Ricardo
Diogo Ricardo
MRMaria Raposo
Maria Raposo
ECEduardo B. Cruz
Eduardo B. Cruz
RORaúl Oliveira
Raúl Oliveira
Maria Filomena CarnideMaria Filomena Carnide
Maria Filomena Carnide
FJFilipa João
Filipa João
Background: Cerebral palsy (CP) is the most common cause of motor disability in children and can cause severe gait deviations. The sagittal gait patterns classification for children with bilateral CP is an important guideline for the planning of the rehabilitation process. Ankle foot orthoses should improve the biomechanical parameters of pathological gait in the sagittal plane. Methods: A systematic search of the literature was conducted to identify randomized controlled trials (RCT) and controlled clinical trials (CCT) which measured the effect of ankle foot orthoses (AFO) on the gait of children with spastic bilateral CP, with kinetic, kinematic, and functional outcomes. Five databases (Pubmed, Scopus, ISI Web of SCIENCE, SciELO, and Cochrane Library) were searched before February 2020. The PEDro Score was used to assess the methodological quality of the selected studies and alignment with the Cochrane approach was also reviewed. Prospero registration number: CRD42018102670. Results: We included 10 studies considering a total of 285 children with spastic bilateral CP. None of the studies had a PEDro score below 4/10, including five RCTs. We identified five different types of AFO (solid; dynamic; hinged; ground reaction; posterior leaf spring) used across all studies. Only two studies referred to a classification for gait patterns. Across the different outcomes, significant differences were found in walking speed, stride length and cadence, range of motion, ground force reaction and joint moments, as well as functional scores, while wearing AFO. Conclusions: Overall, the use of AFO in children with spastic bilateral CP minimizes the impact of pathological gait, consistently improving some kinematic, kinetic, and spatial-temporal parameters, and making their gait closer to that of typically developing children. Creating a standardized protocol for future studies involving AFO would facilitate the reporting of new scientific data and help clinicians use their clinical reasoning skills to recommend the best AFO for their patients.

13 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MRMaria Raquel Raposo
Maria Raquel Raposo
DRDiogo Ricardo
Diogo Ricardo
JTJulia Teles
Julia Teles
AVAntónio Prieto Veloso
António Prieto Veloso
FJFilipa João
Filipa João
Cerebral palsy (CP) is a common cause of motor disability, and pedobarography is a useful, non-invasive, portable, and accessible tool; is easy to use in a clinical setting; and can provide plenty of information about foot–soil interaction and gait deviations. The reliability of this method in children with CP is lacking. The aim of this study is to investigate test–retest reliability and minimal detectable change (MDC) of plantar pressure insole variables in children with CP. Eight children performed two trials 8 ± 2.5 days apart, using foot insoles to collect plantar pressure data. Whole and segmented foot measurements were analyzed using intraclass correlation coefficients (ICC). The variability of the data was measured by calculating the standard error of measurement (SEM) and the MDC/ICC values demonstrated high test–retest reliability for most variables, ranging from good to excellent (ICC ≥ 0.60). The SEM and the MDC values were considered low for the different variables. The variability observed between sessions may be attributed to the heterogeneous sub-diagnosis of CP.

15 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DRDiogo Ricardo
Diogo Ricardo
JTJulia Teles
Julia Teles
MRMaria Raposo
Maria Raposo
AVAntónio Prieto Veloso
António Prieto Veloso
FJFilipa João
Filipa João
Background: Cerebral palsy (CP) is a complex pathology that describes a group of motor disorders with different presentations and functional levels. Three-dimensional gait analysis is widely used in the assessment of CP children to assist in clinical decision making. Thus, it is crucial to assess the repeatability of gait measurements to evaluate the progress of the rehabilitation process. The purpose of the study is to evaluate test-retest reliability of a six-degree-of-freedom (6DoF) marker set in key points of gait kinematics, kinetics, and time-distance parameters in children with CP. Methods: trials were performed on two different days within a period of 7.5 ± 1.4 day. Motion capture data was collected with 14 infrared, high-speed cameras at a frequency rate of 100 Hz, synchronized in time and space with two force plates. Intraclass correlation coefficients considering the two-way mixed model, and absolute agreement (ICC[A,k]) were calculated for anthropometric, time–distance, kinematic and kinetic parameters of both lower limbs. Results: the majority of gait parameters demonstrated a good ICC, and the lowest values were in the kinematic variables. Conclusions: this study indicates wide-ranging reliability values for lower limb joint angles and joint moments of force during gait, especially for frontal and transverse planes. Although the use of a 6DoF-CAST in CP children was shown to be a feasible method, the gait variation that can be observed between sessions in CP children seems to be related not only to the extrinsic factors but also to their different gait patterns and affected sides.

15 February 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RSRui Silva
Rui Silva
Pedro MorouçoPedro Morouço
Pedro Morouço
DRDiogo Ricardo
Diogo Ricardo
ICInês Campos
Inês Campos
Nuno AlvesNuno Alves
Nuno Alves
AVAntónio Prieto Veloso
António Prieto Veloso
Background: The integration of advanced 3D scanning and additive manufacturing technologies in stroke rehabilitation offers promising advancements in the design and production of ankle-foot orthoses. These technological innovations are progressively recognized for their potential to provide more precise and customized orthotic solutions for individuals with stroke-related impairments. Objectives: The primary aim of this study was to biomechanically test and validate the effectiveness of custom ankle-foot orthoses produced through additive manufacturing technology using data captured by a novel photogrammetric scanning system. The customized orthosis was compared with a standard prefabricated orthosis to assess their relative effectiveness in improving gait dynamics and patient satisfaction in stroke rehabilitation. Methods: Participants with equinovarus deformity, a common consequence of stroke, were fitted with custom ankle-foot orthoses, alongside conventional prefabricated orthoses. The study utilized the Qualisys® motion analysis system for comprehensive biomechanical gait analysis, and the QUEST questionnaire was employed to capture participant feedback on both types of orthoses. Detailed comparisons of gait dynamics were conducted using Statistical Parametric Mapping with each orthosis. Results: The study revealed notable kinematic and kinetic differences between the custom and prefabricated orthoses. The custom orthoses demonstrated superior performance in enhancing gait efficiency, symmetry, and safety. Patient feedback favored the customized orthoses over the prefabricated variants, with higher scores in comfort, fit, and overall effectiveness. Conclusions: This research underscores the effectiveness of custom orthoses produced through additive manufacturing technology for stroke rehabilitation. By offering a comprehensive evaluation of orthotic interventions and establishing a comparative framework, the study serves as a reference point for future research, advocating for a more personalized and evidence-based approach in orthotic design for improving the quality of life of stroke survivors.