Rui Silva

Mr. Rui Silva

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2024 in Polymers
Verified
Journal Article
Open access
PDF file
RMRui F. Martins
Rui F. Martins
Ricardo BrancoRicardo Branco
Ricardo Branco
MMMiguel Martins
Miguel Martins
Wojciech MacekWojciech Macek
Wojciech Macek
Zbigniew MarciniakZbigniew Marciniak
Zbigniew Marciniak
CMCândida Malça
Cândida Malça
The study presented herein concerns the mechanical properties of two common polymers for potential biomedical applications, PLA and PETG, processed through fused filament fabrication (FFF)—Material Extrusion (ME). For the uniaxial tension tests carried out, two printing orientations—XY (Horizontal, H) and YZ (Vertical, V)—were considered according to the general principles for part positioning, coordinates, and orientation typically used in additive manufacturing (AM). In addition, six specimens were tested for each printing orientation and material, providing insights into mechanical properties such as Tensile Strength, Young’s Modulus, and Ultimate Strain, suggesting the materials’ potential for biomedical applications. The experimental results were then compared with correspondent mechanical properties obtained from the literature for other polymers like ASA, PC, PP, ULTEM 9085, Copolyester, and Nylon. Thereafter, fatigue resistance curves (S-N curves) for PLA and PETG, printed along 45°, were determined at room temperature for a load ratio, R, of 0.2. Scanning electron microscope observations revealed fibre arrangements, compression/adhesion between layers, and fracture zones, shedding light on the failure mechanisms involved in the fatigue crack propagation of such materials and giving design reference values for future applications. In addition, fractographic analyses of the fatigue fracture surfaces were carried out, as well as X-ray Computed Tomography (XCT) and Thermogravimetric (TGA)/Differential Scanning Calorimetric (DSC) tests.

20 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
RSRui Silva
Rui Silva
.S.Bruna Filipe Silva
.Bruna Filipe Silva
CFCristiana Fernandes
Cristiana Fernandes
Pedro MorouçoPedro Morouço
Pedro Morouço
Nuno AlvesNuno Alves
Nuno Alves
AVAntónio Prieto Veloso
António Prieto Veloso
When a limb suffers a fracture, rupture, or dislocation, it is traditionally immobilized with plaster. This may induce discomfort in the patient, as well as excessive itching and sweating, which creates the growth of bacteria, leading to an unhygienic environment and difficulty in keeping the injury clean during treatment. Furthermore, if the plaster remains for a long period, it may cause lesions in the joints and ligaments. To overcome all of these disadvantages, orthoses have emerged as important medical devices to help patients in rehabilitation, as well as for self-care of deficiencies in clinics and daily life. Traditionally, these devices are produced manually, which is a time-consuming and error-prone method. From another point of view, it is possible to use imageology (X-ray or computed tomography) to scan the human body; a process that may help orthoses manufacturing but which induces radiation to the patient. To overcome this great disadvantage, several types of 3D scanners, without any kind of radiation, have emerged. This article describes the use of various types of scanners capable of digitizing the human body to produce custom orthoses. Studies have shown that photogrammetry is the most used and most suitable 3D scanner for the acquisition of the human body in 3D. With this evolution of technology, it is possible to decrease the scanning time and it will be possible to introduce this technology into clinical environment.

9 June 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
RSRui Silva
Rui Silva
AVAntónio Prieto Veloso
António Prieto Veloso
Nuno AlvesNuno Alves
Nuno Alves
CFCristiana Fernandes
Cristiana Fernandes
Pedro MorouçoPedro Morouço
Pedro Morouço
Ankle-foot orthoses (AFO) are prescribed to improve the patient’s quality of life. Supporting weak muscles or restraining spastic muscles leads to smoother and more stable locomotion. Commonly, AFO are made using thermoplastic vacuum forming, which requires a long time for production and has limited design options. Additive manufacturing (AM) can solve this problem, leading to a faster and cheaper solution. This review aimed to investigate what is the state-of-art using AM for AFO. Evaluating the used manufacturing processes, customization steps, mechanical properties, and biomechanical features in humans would provide significant insights for further research. The database searches combined AM and AFO with no year or publication type restrictions. Studies must have examined outcomes on human participants with the orthoses built by AM. Other types of orthotic devices or different manufacturing techniques were excluded. Nineteen studies met the inclusion criteria. As stated by having all studies conducted in the last nine years, this is a very recent domain. Different AM processes have been used, with the majority relying on Fused Deposition Modeling. Overall, the manuscripts’ quality is deficient, which is critical to promoting further studies with higher samples. Except for one paper, AM-printed AFO was comparable or superior to the thermoplastic vacuum forming AFO in mechanical tests, kinematics, kinetics, and participant feedback.

10 September 2024 in Polymers
Verified
Journal Article
Open access
PDF file
DTDaniela Trindade
Daniela Trindade
RHRachel DJONYABE Habiba
Rachel DJONYABE Habiba
CFCristiana Fernandes
Cristiana Fernandes
André Antão CostaAndré Antão Costa
André Antão Costa
RSRui Silva
Rui Silva
Carla MouraCarla Moura
Carla Moura
Orthoses are commonly used for treating injuries to improve the quality of life of patients, with customized orthoses offering significant benefits. Additive manufacturing, especially fused deposition modelling, enhances these benefits by providing faster, more precise, and more comfortable orthoses. The present study evaluates nine polymeric materials printed in horizontal and vertical directions by assessing their performance through compressive, flexural, and tensile tests. Among all materials, polycarbonate, polylactic acid, and ULTEMTM 1010 showed the most promising results, not only because they had the highest mechanical values, but also due to their minimal or no difference in performance between printing directions, making them advantageous in orthoses fabrication. Based on this, a finite element model of an ankle–foot orthosis was developed to simulate the deformation, strain, and stress fields under static conditions. The findings aim to optimize material selection for orthotic fabrication, where ULTEMTM 1010 is presented as the material with improved performance and durability.

28 June 2024 in Polymers
Verified
Journal Article
Open access
PDF file
RHRachel DJONYABE Habiba
Rachel DJONYABE Habiba
Ana Martins AmaroAna Martins Amaro
Ana Martins Amaro
DTDaniela Trindade
Daniela Trindade
Carla MouraCarla Moura
Carla Moura
RSRui Silva
Rui Silva
Ricardo BrancoRicardo Branco
Ricardo Branco
Orthotic devices play an important role in medical treatment, addressing various pathologies and promoting patient recovery. Customization of orthoses to fit individual patient morphologies and needs is essential for optimal functionality and patient comfort. The advent of additive manufacturing has revolutionized the biomedical field, offering advantages such as cost reduction, increased personalization, and enhanced dimensional adaptability for orthotics manufacturing. This research focuses on the impact strength of nine polymeric materials printed by additive manufacturing, including an evaluation of the materials’ performance under varying conditions comprising different printing directions (vertical and horizontal) and exposure to artificial sweat for different durations (0 days, 24 days, and 189 days). The results showed that Nylon 12 is good for short-term (24 days) immersion, with absorbed energies of 78 J and 64 J for the vertical and horizontal directions, whereas Polycarbonate (PC) is good for long-term immersion (189 days), with absorbed energies of 66 J and 78 J for the vertical and horizontal directions. Overall, the findings contribute to a better understanding of the suitability of these materials for biomedical applications, considering both short-term and long-term exposure to physiological and environmental conditions.

2 April 2024 in JMIR Research Protocols
Verified
Journal Article
Open access
RSRui Silva
Rui Silva
Pedro MorouçoPedro Morouço
Pedro Morouço
JLJorge Lains
Jorge Lains
PAPaula Amorim
Paula Amorim
Nuno AlvesNuno Alves
Nuno Alves
AVAntónio Prieto Veloso
António Prieto Veloso
Background: Ankle-foot orthoses (AFOs) are vital in gait rehabilitation for patients with stroke. However, many conventional AFO designs may not offer the required precision for optimized patient outcomes. With the advent of 3D scanning and printing technology, there is potential for more individualized AFO solutions, aiming to enhance the rehabilitative process. Objective: This nonrandomized trial seeks to introduce and validate a novel system for AFO design tailored to patients with stroke. By leveraging the capabilities of 3D scanning and bespoke software solutions, the aim is to produce orthoses that might surpass conventional designs in terms of biomechanical effectiveness and patient satisfaction. Methods: A distinctive 3D scanner, complemented by specialized software, will be developed to accurately capture the biomechanical data of leg movements during gait in patients with stroke. The acquired data will subsequently guide the creation of patient-specific AFO designs. These personalized orthoses will be provided to participants, and their efficacy will be compared with traditional AFO models. The qualitative dimensions of this experience will be evaluated using the Quebec User Evaluation of Satisfaction With Assistive Technology (QUEST) assessment tool. Feedback from health care professionals and the participants will be considered throughout the trial to ensure a rounded understanding of the system’s implications. Results: Spatial-temporal parameters will be statistically compared using paired t tests to determine significant differences between walking with the personalized orthosis, the existing orthosis, and barefoot conditions. Significant differences will be identified based on P values, with P<.05 indicating statistical significance. The Statistical Parametric Mapping method will be applied to graphically compare kinematic and kinetic data across the entire gait cycle. QUEST responses will undergo statistical analysis to evaluate patient satisfaction, with scores ranging from 1 (not satisfied) to 5 (very satisfied). Satisfaction scores will be presented as mean and SD values. Significant variations in satisfaction levels between the personalized and existing orthosis will be assessed using a Wilcoxon signed rank test. The anticipation is that the AFOs crafted through this innovative system will either match or outperform existing orthoses in use, with higher patient satisfaction rates. Conclusions: Embracing the synergy of technology and biomechanics may hold the key to revolutionizing orthotic design, with the potential to set new standards in patient-centered orthotic solutions. However, as with all innovations, a balanced approach, considering both the technological possibilities and individual patient needs, will be paramount to achieving optimal outcomes. International Registered Report Identifier (IRRID): PRR1-10.2196/52365