Dipali Bansal

Prof. Dr. Dipali Bansal

Manav Rachna University, Faridabad, Faridabad, India
orcid
Dean School of Engineering, Manav Rachna University, Faridab...

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2009 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
Dipali BansalDipali Bansal
Dipali Bansal
MKMunna Khan
Munna Khan
ASAshok K. Salhan
Ashok K. Salhan

1 March 2009
Verified
Conference Paper
Closed access
Dipali BansalDipali Bansal
Dipali Bansal
MKMunna Khan
Munna Khan
ASA.K. Salhan
A.K. Salhan
Electrocardiogram (ECG) is one of the most important physiological parameter that gives correct assessment of heart function. QRS complex is a prominent waveform in an ECG that provides the basis for analyzing heart rate variability (HRV). HRV refers to the beat-to-beat alterations in heart rate. Commercial devices these days provide preset computerized measurement of HRV, thus providing the cardiologist a simple tool for both research and clinical learning. To obtain meaningful data from the ECG, a noise free inter-beat interval (IBI) time series is required to be extracted. This is realized using standard peak detection algorithms packed with data acquisition hardware and software. The aim of this paper is to describe various QRS detection methods used to derive HRV. It also reviews various time and frequency domain HRV parameters. The significance and meaning of these different measures of HRV are a potential area of research.

1 January 2017 in Procedia Computer Science
Verified
Journal Article
Open access
RMRashima Mahajan
Rashima Mahajan
Dipali BansalDipali Bansal
Dipali Bansal

1 February 2014
Verified
Conference Paper
Closed access
SBSande Seema Bhogeshwar
Sande Seema Bhogeshwar
MSM.K. Soni
M.K. Soni
Dipali BansalDipali Bansal
Dipali Bansal
Electrocardiogram ECG signal is usually corrupted by several artifacts and these must be removed before diagnosis. This paper therefore presents the design of various FIR filters like Kaiser, Rectangular, Hamming, Hanning, Gaussian and Bartllet window techniques and FIR Equiripple Filter. IIR filters like Butterworth, Chebychev I & II and Elliptic Filters are also explored to remove the artifacts in ECG signal. To verify the usability of designed filters, noisy ECG signal is generated by adding random noise, white noise and 50 Hz interference (hum) to the 100m.mat ECG data sample taken from MIT-BIH database. Signal to noise ratio (SNR) is calculated to compare the performance of different filtering methods using Simulink Model. Results obtained show that FIR Equiripple filter gives a SNR of 7.71 for a 3rd order filter and IIR Elliptic filter has SNR of for first order filter and are therefore recommended.

1 October 2015
Verified
Conference Paper
Closed access
RMRashima Mahajan
Rashima Mahajan
Dipali BansalDipali Bansal
Dipali Bansal
Tachycardia and bradycardia are the most common type of heart beat abnormalities. These are caused by disruption of normal heart impulses which makes flow of blood and oxygen to vital body organs too rapid in tachycardia and too slow in bradycardia. This may lead to heart, brain and other organs damage. An attempt has been made in this paper to distinguish the normal heart rhythm from that of irregular ones. Electrocardiogram (ECG) signal processing provides information regarding the functionality of heart and thus helps in detecting cardiac abnormalities. Heart rate analysis of ECG provides the associated heart rate, an indicator of heart beats per minute. However, it does not give any information regarding strength of variations and thus distribution of power. Power spectral analysis using the fast Fourier transform (FFT) is performed to detect and characterize strength of variations in ECG with respect to frequency. The algorithm was tested on normal, bradycardia and tachycardia ECG rhythms loaded from MIT-BIH arrhythmia database of Physiobank ATM. Distinct heart beat abnormalities are found to be correlated with distinct frequency components in respective power spectrum. The inferences drawn from results demonstrate the potential of proposed algorithm that could be developed as an effective computer-aided diagnostic tool to identify heart beat abnormalities in ECGs.

1 January 2014 in International Journal of Biomedical Engineering and Technology
Verified
Journal Article
Closed access
SBSande Seema Bhogeshwar
Sande Seema Bhogeshwar
MSM.K. Soni
M.K. Soni
Dipali BansalDipali Bansal
Dipali Bansal
Electrocardiogram (ECG) plays an important role in diagnostics of cardiac diseases. In general, ECG signals are affected by noises during data acquisition. For accurate treatment, doctors need noise-free ECG signals. This paper presents a detailed analysis of algorithms for denoising ECG signals using different IIR filters like Butterworth filter, Elliptic Filter, Types I and II Chebyshev, and FIR filters like Zero-phase low pass filter, Hamming window and rectangular window. An attempt has been carried out for denoising of ECG signals using ECG data sample from the MIT-BIH database for different noises like random noise, white noise and 50-Hz interference (hum). The performances are evaluated using MATLAB and compared in terms of Signal-to-Noise Ratio (SNR), error and accuracy by calculating the standard deviation using Wavelet toolbox. Simulation study shows that the highest SNR, i.e. 49.03, is obtained with the Butterworth filter, whereas the highest accuracy, i.e. 99.58%, is obtained with the zero-phase low pass filter.