Munna Khan

Prof. Munna Khan

Jamia Millia Islamia, New Delhi, Delhi, International

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Robotics and Autonomous Systems
Verified
Journal Article
Closed access
KSKashif I.K. Sherwani
Kashif I.K. Sherwani
NKNeelesh Kumar
Neelesh Kumar
ACAhmed Chemori
Ahmed Chemori
MKMunna Khan
Munna Khan
SMSamer Mohammed
Samer Mohammed

4 March 2009 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
Dipali BansalDipali Bansal
Dipali Bansal
MKMunna Khan
Munna Khan
ASAshok K. Salhan
Ashok K. Salhan

1 March 2009
Verified
Conference Paper
Closed access
Dipali BansalDipali Bansal
Dipali Bansal
MKMunna Khan
Munna Khan
ASA.K. Salhan
A.K. Salhan
Electrocardiogram (ECG) is one of the most important physiological parameter that gives correct assessment of heart function. QRS complex is a prominent waveform in an ECG that provides the basis for analyzing heart rate variability (HRV). HRV refers to the beat-to-beat alterations in heart rate. Commercial devices these days provide preset computerized measurement of HRV, thus providing the cardiologist a simple tool for both research and clinical learning. To obtain meaningful data from the ECG, a noise free inter-beat interval (IBI) time series is required to be extracted. This is realized using standard peak detection algorithms packed with data acquisition hardware and software. The aim of this paper is to describe various QRS detection methods used to derive HRV. It also reviews various time and frequency domain HRV parameters. The significance and meaning of these different measures of HRV are a potential area of research.

1 January 2015 in International Journal of Bioinformatics Research and Applications
Verified
Journal Article
Closed access
SSSavita Sondhi
Savita Sondhi
MKMunna Khan
Munna Khan
RVRitu Vijay
Ritu Vijay
ASAshok K. Salhan
Ashok K. Salhan
SCSatish Chouhan
Satish Chouhan
When a person is emotionally charged, stress could be discerned in his voice. This paper presents a simplified and a non-invasive approach to detect psycho-physiological stress by monitoring the acoustic modifications during a stressful conversation. Voice database consists of audio clips from eight different popular FM broadcasts wherein the host of the show vexes the subjects who are otherwise unaware of the charade. The audio clips are obtained from real-life stressful conversations (no simulated emotions). Analysis is done using PRAAT software to evaluate mean fundamental frequency (F0) and formant frequencies (F1, F2, F3, F4) both in neutral and stressed state. Results suggest that F0 increases with stress; however, formant frequency decreases with stress. Comparison of Fourier and chirp spectra of short vowel segment shows that for relaxed speech, the two spectra are similar; however, for stressed speech, they differ in the high frequency range due to increased pitch modulation.

1 December 2018 in Ain Shams Engineering Journal
Verified
Journal Article
Open access
MKMunna Khan
Munna Khan
ASAnwar Shahzad Siddiqui
Anwar Shahzad Siddiqui
ASAmged Sayed
Amged Sayed
This paper concerns with designing of a robust H∞ controller for Magnetic Levitation system exposed to external disturbances. First, the Maglev is modeled in a discrete form of Takagi–Sugeno fuzzy (TSF) system. Then the nonlinear fuzzy controller is synthesized based on such a technique called Parallel Distributed Compensation (PDC) schemes and sufficient conditions are developed to control and guarantee the robust stabilization of a complex nonlinear system. So the proposed algorithm is used to enhance the performance and to ensure the stability of the system. Furthermore, the design conditions and criteria for quadratic stability of the TSF system are formulated as a Linear Matrix Inequality (LMI) to robustly stabilize the position of the iron ball in a Maglev system in the existence of disturbances. The proposed technique will guarantee H∞ performance to be less than one and attenuate the effect of exogenous disturbances. Moreover, the comparison results for the control of Maglev will show the capability of the proposed approach

1 November 2016
Verified
Conference Paper
Closed access
SSSavita Sondhi
Savita Sondhi
RVRitu Vijay
Ritu Vijay
MKMunna Khan
Munna Khan
ASAshok K. Salhan
Ashok K. Salhan
Human voice can signal the psychological state of an individual. Be it emotional, physical, intentional or unconscious, voice reveals the internal state of the speaker. Therefore, the main aim of the present study is to identify which voice parameter could be used as a reliable indicator of stress due to deception. For analyzing real life natural stress, the voice of crime suspects was recorded during ongoing interrogations at the police station. PRAAT software was used for analysis. Results indicated a significant increase in the mean fundamental frequency (F0) and formant frequencies F1, F2. Marginal decrease in jitter was observed, however, shimmer did not at all correlate to stress due to deception. Pitch contours indicated considerable rise in the pitch of crime suspects while answering specific direct questions. Thus, it was concluded that mean F0 and formant frequencies F1, F2 correlate strongly to stress.