DongYeong Gwon

Mr. DongYeong Gwon

Daegu Catholic University, Daegu, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2022 in Electronics
Verified
Journal Article
Open access
PDF file
DongYeong GwonDongYeong Gwon
DongYeong Gwon
YCYun-Hyuk Choi
Yun-Hyuk Choi
JSJUNBO SIM
JUNBO SIM
Problems with overvoltage and reverse energy flow arise as the percentage of distribution energy resources (DERs) in distribution system rises. This paper implements a MATLAB/Simulink linked model that communicates with the OpenDSS engine. The point of common coupling (PCC) voltage typically mitigates using the inverter outputs control. However, case overvoltage issues occur in distribution networks and the influence of the volt–var control effect is insufficient to reduce PCC voltage to a stable range. To improve the reactive control effect, this paper proposes active power control and voltage error compensation methods that maximize the reactive power control effect. The DER management system (DERMS) platform was constructed to analyze the effect of changing DER output values. The DERMS data are organized based on real distribution line (D/L) system data where overvoltage occurred in Korea and the control effect of the real system is analyzed. This control method analysis can be used to develop an inverter control scheme for the over voltage issues described in this paper.

26 January 2026 in Electronics
Verified
Journal Article
Open access
PDF file
DongYeong GwonDongYeong Gwon
DongYeong Gwon
YCYun-Hyuk Choi
Yun-Hyuk Choi
This study investigated the fault ride through capability of inverter-based resources in weak distribution networks and proposes a fault-oriented reactive power compensation strategy using only point of common coupling voltage measurements. The proposed strategy determines the reactive power command based on the minimum phase voltage, which represents the most severely depressed phase during unbalanced faults, without fault type detection or sequence component analysis. As a result, the same control framework can be applied to single-line-to-ground, double-line-to-ground, and three-phase faults. A detailed MATLAB/Simulink model of a Korean distribution feeder was developed using actual system parameters. The proposed strategy was compared with a no control case and a conservative fixed capacity reactive power injection scheme derived from commonly adopted power factor limits. Simulation results show that the no control case provides no voltage support, while the fixed capacity approach yields limited improvement in weak grids. In contrast, the proposed strategy maintains stable inverter operation and improves voltage recovery. At locations with an extremely low weighted short circuit ratio of 0.303, the proposed strategy prevents inverter tripping during temporary faults and satisfies low voltage ride through requirements, demonstrating its practical effectiveness.

29 September 2026 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
SLSang-Hyeon Lee
Sang-Hyeon Lee
DongYeong GwonDongYeong Gwon
DongYeong Gwon
JSJUNBO SIM
JUNBO SIM
YCYun-Hyuk Choi
Yun-Hyuk Choi