Ling Ling Tan

Dr. Ling Ling Tan

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
NINadiah Ibrahim
Nadiah Ibrahim
NJNur Diyana Jamaluddin
Nur Diyana Jamaluddin
LTLing Ling Tan
Ling Ling Tan
NYNurul Yuziana Mohd Yusof
Nurul Yuziana Mohd Yusof
The emergence of highly pathogenic and deadly human coronaviruses, namely SARS-CoV and MERS-CoV within the past two decades and currently SARS-CoV-2, have resulted in millions of human death across the world. In addition, other human viral diseases, such as mosquito borne-viral diseases and blood-borne viruses, also contribute to a higher risk of death in severe cases. To date, there is no specific drug or medicine available to cure these human viral diseases. Therefore, the early and rapid detection without compromising the test accuracy is required in order to provide a suitable treatment for the containment of the diseases. Recently, nanomaterials-based biosensors have attracted enormous interest due to their biological activities and unique sensing properties, which enable the detection of analytes such as nucleic acid (DNA or RNA), aptamers, and proteins in clinical samples. In addition, the advances of nanotechnologies also enable the development of miniaturized detection systems for point-of-care (POC) biosensors, which could be a new strategy for detecting human viral diseases. The detection of virus-specific genes by using single-stranded DNA (ssDNA) probes has become a particular interest due to their higher sensitivity and specificity compared to immunological methods based on antibody or antigen for early diagnosis of viral infection. Hence, this review has been developed to provide an overview of the current development of nanoparticles-based biosensors that target pathogenic RNA viruses, toward a robust and effective detection strategy of the existing or newly emerging human viral diseases such as SARS-CoV-2. This review emphasizes the nanoparticles-based biosensors developed using noble metals such as gold (Au) and silver (Ag) by virtue of their powerful characteristics as a signal amplifier or enhancer in the detection of nucleic acid. In addition, this review provides a broad knowledge with respect to several analytical methods involved in the development of nanoparticles-based biosensors for the detection of viral nucleic acid using both optical and electrochemical techniques.

22 July 2014 in Sensors
Verified
Journal Article
Open access
PDF file
MAMuawia Alqasaimeh
Muawia Alqasaimeh
LHLee Yook Heng
Lee Yook Heng
MAMusa Ahmad
Musa Ahmad
ARA.S. Santhana Raj
A.S. Santhana Raj
LTLing Ling Tan
Ling Ling Tan
A new silica-gel nanospheres (SiO2NPs) composition was formulated, followed by biochemical surface functionalization to examine its potential in urea biosensor development. The SiO2NPs were basically synthesized based on sol–gel chemistry using a modified Stober method. The SiO2NPs surfaces were modified with amine (-NH2) functional groups for urease immobilization in the presence of glutaric acid (GA) cross-linker. The chromoionophore pH-sensitive dye ETH 5294 was physically adsorbed on the functionalized SiO2NPs as pH transducer. The immobilized urease determined urea concentration reflectometrically based on the colour change of the immobilized chromoionophore as a result of the enzymatic hydrolysis of urea. The pH changes on the biosensor due to the catalytic enzyme reaction of immobilized urease were found to correlate with the urea concentrations over a linear response range of 50–500 mM (R2 = 0.96) with a detection limit of 10 mM urea. The biosensor response time was 9 min with reproducibility of less than 10% relative standard deviation (RSD). This optical urea biosensor did not show interferences by Na+, K+, Mg2+ and NH4+ ions. The biosensor performance has been validated using urine samples in comparison with a non-enzymatic method based on the use of p-dimethylaminobenzaldehyde (DMAB) reagent and demonstrated a good correlation between the two different methods (R2 = 0.996 and regression slope of 1.0307). The SiO2NPs-based reflectometric urea biosensor showed improved dynamic linear response range when compared to other nanoparticle-based optical urea biosensors.

22 January 2016 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
DFDedi Futra
Dedi Futra
LHLee Yook Heng
Lee Yook Heng
MJMohamad Zudaidy Jaapar
Mohamad Zudaidy Jaapar
AUAlizar Ulianas
Alizar Ulianas
KSKasra Saeedfar
Kasra Saeedfar
LTLing Ling Tan
Ling Ling Tan
Molecularly imprinted polymers (MIPs) are generally a more stable material for sensing application. The high selectivity and sensitivity of MIPs for sensors can be achieved if the template molecule is imprinted in the polymer and this makes them an ideal alternative as a recognition element for sensors. A new electrochemical sensor based on molecularly imprinted polymeric microspheres (MIPs) and multi-walled carbon nanotube/gold nanoparticle (MIP–MWCNT–AuNP) modified carbon screen-printed electrodes (SPEs) for the rapid detection of 17β-estradiol (E) hormone in serum samples has been successfully developed. Hydrophobic MIPs were synthesized using photopolymerization in emulsion form. The multi-walled carbon nanotube grafted with gold nanoparticles was firstly deposited onto a carbon screen-printed electrode for the purpose of accelerating electron transfer to the surface of the electrode. The MIP microspheres specific to the 17β-estradiol hormone, prepared via a facile photopolymerization technique, were coated onto the MWCNT–AuNP modified SPE. The presence of 17β-estradiol in biological samples could be detected with the sensor via absorption of 17β-estradiol into the deposited MIPs and this was monitored by differential pulse voltammetry (DPV) at 0.6 V for the reduction of 17β-estradiol. Under optimal conditions, the sensor could detect the concentrations of 17β-estradiol from 1.0 × 10−15 to 1.0 × 10−6 M (R2 = 0.9921), with a detection limit of 2.5 × 10−16 M. The sensor based on MIP microspheres and the MWCNT–AuNP modified electrode demonstrated a stability of 55 days with good reproducibility (RSD < 5%, n = 5) and regenerability (RSD < 4%, n = 5). Using this sensor, the gender of the arowana fish determined via the level of 17β-estradiol using fish serum samples demonstrated good agreement with a conventional test kit based on the immuno-assay method.

5 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Nur Syamimi MohamadNur Syamimi Mohamad
Nur Syamimi Mohamad
NZNur Hanis Zakaria
Nur Hanis Zakaria
NDNurulhaidah Daud
Nurulhaidah Daud
LTLing Ling Tan
Ling Ling Tan
GTGoh Choo Ta
Goh Choo Ta
Nurul Izzaty HassanNurul Izzaty Hassan
Nurul Izzaty Hassan
Mass-spectrometry-based and X-ray fluorescence-based techniques have allowed the study of the distribution of Zn2+ ions at extracellular and intracellular levels over the past few years. However, there are some issues during purification steps, sample preparation, suitability for quantification, and the instruments’ availability. Therefore, work on fluorescent sensors based on 8-aminoquinoline as tools to detect Zn2+ ions in environmental and biological applications has been popular. Introducing various carboxamide groups into an 8-aminoquinoline molecule to create 8-amidoquinoline derivatives to improve water solubility and cell membrane permeability is also a recent trend. This review aims to present a general overview of the fluorophore 8-aminoquinoline and its derivatives as Zn2+ receptors for zinc sensor probes. Various fluorescent chemosensor designs based on 8-amidoquinoline and their effectiveness and potential as a recognition probe for zinc analysis were discussed. Based on this review, it can be concluded that derivatives of 8-amidoquinoline have vast potential as functional receptors for zinc ions primarily because of their fast reactivity, good selectivity, and bio-compatibility, especially for biological applications. To better understand the Zn2+ ion fluorophores’ function, diversity of the coordination complex and geometries need further studies. This review provides information in elucidating, designing, and exploring new 8-amidoquinoline derivatives for future studies for the improvement of chemosensors that are selective and sensitive to Zn2+.

26 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
EAEda Yuhana Ariffin
Eda Yuhana Ariffin
LHLee Yook Heng
Lee Yook Heng
LTLing Ling Tan
Ling Ling Tan
NKNurul Huda Abd Karim
Nurul Huda Abd Karim
SHSiti Aishah Hasbullah
Siti Aishah Hasbullah
A novel label-free electrochemical DNA biosensor was constructed for the determination of Escherichia coli bacteria in environmental water samples. The aminated DNA probe was immobilized onto hollow silica microspheres (HSMs) functionalized with 3-aminopropyltriethoxysilane and deposited onto a screen-printed electrode (SPE) carbon paste with supported gold nanoparticles (AuNPs). The biosensor was optimized for higher specificity and sensitivity. The label-free E. coli DNA biosensor exhibited a dynamic linear response range of 1 × 10−10 µM to 1 × 10−5 µM (R2 = 0.982), with a limit of detection at 1.95 × 10−15 µM, without a redox mediator. The sensitivity of the developed DNA biosensor was comparable to the non-complementary and single-base mismatched DNA. The DNA biosensor demonstrated a stable response up to 21 days of storage at 4 ℃ and pH 7. The DNA biosensor response was regenerable over three successive regeneration and rehybridization cycles.

27 April 2012 in Sensors
Verified
Journal Article
Open access
PDF file
AUAlizar Ulianas
Alizar Ulianas
LHLee Yook Heng
Lee Yook Heng
SHSharina Abu Hanifah
Sharina Abu Hanifah
LTLing Ling Tan
Ling Ling Tan
An electrochemical microbiosensor for DNA has been fabricated based on new acrylic microspheres modified with reactive N-acryloxysuccinimide (NAS) functional groups. Hydrophobic poly(n-butylacrylate-N-acryloxysuccinimide) microspheres were synthesized in an emulsion form with a simple one-step photopolymerization technique. Aminated DNA probe was attached to the succinimde functional group of the acrylic microspheres via covalent bonding. The hybridization of the immobilized DNA probe with the complementary DNA was studied by differential pulse voltametry using anthraquninone-2-sulfonic acid monohydrate sodium salt (AQMS) as the electroactive hybridization label. The influences of many factors such as duration of DNA probe immobilization and hybridization, pH, type of ions, buffer concentrations, ionic strength, operational temperature and non-complementary DNA on the biosensor performance were evaluated. Under optimized conditions, the DNA microbiosensor demonstrated a linear response range to target DNA over a wide concentration range of 1.0 × 10−16 and 1.0 ´ 10−8 M with a lower limit of detection (LOD) of 9.46 ´ 10−17 M (R2 = 0.97). This DNA microbiosensor showed good reproducibility with 2.84% RSD (relative standard deviation) (n = 3). Application of the NAS-modified acrylic microspheres in the construction of DNA microbiosensor had improved the overall analytical performance of the resultant DNA microbiosensor when compared with other reported DNA biosensors using other nano-materials for membranes and microspheres as DNA immobilization matrices.