Failure of osteosynthesis implants is an intricate matter with challenging management that calls for efficient investigation and prevention. Using implant retrieval analysis combined with standard radiological examination, we evaluated the main causes for osteosynthesis implant breakdown and the relations among them for a series of cases. Twenty-one patients diagnosed with implant failure were assessed for this work. For metallurgical analysis, microscopy techniques such as scanning electron microscopy (SEM), stereomicroscopy, and optical microscopy were employed. The results showed that material structural deficiencies (nine patients) and faulty surgical techniques (eight patients) were the main causes for failure. An important number of patients presented with material structural deficiencies superimposed on an imperfect osteosynthesis technique (six patients). Consequently, the importance of failure retrieval analysis should not be overlooked, and in combination with other investigational techniques, must provide information for both implant manufacturing and design improvement, as well as osteosynthesis technique optimization.
8 January 2023 in Romanian Journal of Military Medicine
"Total hip replacement surgery (THR) is one of the most common surgeries performed in modern orthopedics, and in most cases offers a significant improvement in the quality of the patient's life. However, after some time, wear and osteolysis do appear, which leads to the need for revision surgery. With the indication being widened to a more young and active population, the need for extending the lifespan of the prosthesis is mandatory. Although several bearing surfaces have been studied over the years, and a lot of couplings are in use, the choice of the right combination of materials is still controversial. Biotribology tries to answer some of the current questions regarding the best bearing surface to use, being the branch of science and technology that studies friction, wear, and lubrication of different materials in the human body. In the present day, a large number of materials are in use for total hip replacement, but choosing the right combination of materials is still controversial, and is being done on one hand by the surgeon’s experience and on the other hand by the age and activity of the patient. The objective of this review is to try to present the main advantages and disadvantages of different materials and try to answer the most difficult question of them all: What is the right material to use for THR-bearing surfaces? "
Background/Objectives: Emergency surgical patients are at increased risk of acute postoperative delirium. Processed EEG monitoring, such as entropy indices and burst suppression ratio (BSR), may optimize anesthetic dosing, yet their role in non-elective surgery remains underexplored. This retrospective cohort study aimed to examine whether entropy monitoring and intraoperative burst suppression are associated with the incidence of early postoperative delirium during the first 72 h after emergency surgery. Methods: Adult patients undergoing emergency surgery between March 2022 and March 2024 were classified into two groups based on anesthesia records: the entropy-monitored group (EG) and the standard care group without processed EEG (SG). Demographic, intraoperative, and cognitive data (NEECHAM scores during the first 72 h) were extracted from institutional perioperative records. The primary outcome was postoperative delirium (NEECHAM ≤ 24), with secondary analyses examining anesthetic exposure, burst suppression, and intraoperative hemodynamics. Results: Entropy-monitored patients received lower sevoflurane and fentanyl doses and exhibited improved hemodynamic stability, including fewer hypotensive episodes and lower norepinephrine requirements. Early postoperative cognitive dysfunction (NEECHAM ≤ 24) was more frequent among patients with intraoperative burst suppression, with BSR > 15% or suppression duration > 6 min strongly associated with cognitive decline within the first 72 h. Conclusions: In this retrospective cohort, entropy-guided anesthesia was associated with more precise anesthetic titration and more stable hemodynamic parameters. Burst suppression characteristics may serve as indicators of neurocognitive vulnerability rather than solely reflecting direct effects of anesthetic dosing. These results support the use of processed EEG monitoring in emergency surgery, though prospective studies are needed to confirm these findings.
Current paper is aiming to show the obtained results in manufacturing and characterization of graphite-based and metal composite materials suitable to be used in high voltage application of automotive field. Thus, 4 types of materials have been processed and tested in order to assess their suitability to be used as current collector material for trolleybus. The novelty of this work is the new innovative technological process for obtaining the carbon/metal composite material used in the manufacture of sliding contacts for electrical current collector heads, as well as the character-istics obtained for this material. All 4 obtained materials have been characterized from structural (by optical microscopy), mechanical (density, electrical resistivity, hardness) and functional point of view (wear after 1000 working hours, electric discharge and electric load) and it was determined that the material which uses chemically copper covered graphite is the most suitable of them and has been chosen to be further developed by the end beneficiary.
Current paper is aiming to show the obtained results in manufacturing and characterization of graphite-based and metal composite materials suitable to be used in high voltage applications of automotive and/or aviation field. Thus, 4 types of materials have been processed and tested in order to assess their suitability to be used as current collector material for electric engines. The novelty of this work is the presentation of the new innovative technological process for obtaining the carbon/metal composite material used in the manufacture of sliding contacts for current collector heads, as well as the characteristics obtained for this material. All 4 obtained materials have been characterized from structural, mechanical and functional point of view and the most suitable of them has been chosen to be further developed by the end beneficiary.