Eduardo Gallego

Prof. Eduardo Gallego

Technical University of Madrid, Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 1995 in Physics Letters B
Verified
Journal Article
Closed access
SAS. Andriamonje
S. Andriamonje
AAA. Angelopoulos
A. Angelopoulos
AAA. Apostolakis
A. Apostolakis
FAF. Attale
F. Attale
LBL. Brillard
L. Brillard
GZG. Zarris
G. Zarris

31 May 2022 in Antioxidants
Verified
Journal Article
Open access
PDF file
ELENA OBRADORELENA OBRADOR
ELENA OBRADOR
RPRosario Salvador Palmer
Rosario Salvador Palmer
JVJuan I. Villaescusa
Juan I. Villaescusa
EGEduardo Gallego
Eduardo Gallego
BPBlanca Pellicer
Blanca Pellicer
Alegria MontoroAlegria Montoro
Alegria Montoro
Atomic and radiological crises can be caused by accidents, military activities, terrorist assaults involving atomic installations, the explosion of nuclear devices, or the utilization of concealed radiation exposure devices. Direct damage is caused when radiation interacts directly with cellular components. Indirect effects are mainly caused by the generation of reactive oxygen species due to radiolysis of water molecules. Acute and persistent oxidative stress associates to radiation-induced biological damages. Biological impacts of atomic radiation exposure can be deterministic (in a period range a posteriori of the event and because of destructive tissue/organ harm) or stochastic (irregular, for example cell mutation related pathologies and heritable infections). Potential countermeasures according to a specific scenario require considering basic issues, e.g., the type of radiation, people directly affected and first responders, range of doses received and whether the exposure or contamination has affected the total body or is partial. This review focuses on available medical countermeasures (radioprotectors, radiomitigators, radionuclide scavengers), biodosimetry (biological and biophysical techniques that can be quantitatively correlated with the magnitude of the radiation dose received), and strategies to implement the response to an accidental radiation exposure. In the case of large-scale atomic or radiological events, the most ideal choice for triage, dose assessment and victim classification, is the utilization of global biodosimetry networks, in combination with the automation of strategies based on modular platforms.

1 September 2007 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
EGEduardo Gallego
Eduardo Gallego
EME Migoya
E Migoya
JMJ Martinvaldepenas
J Martinvaldepenas
ACA Crespo
A Crespo
JGJ Garcia
J Garcia
YDY Dagba
Y Dagba

1 March 2007 in Radiation Measurements
Verified
Journal Article
Closed access
HVHector Rene Vega-Carrillo
Hector Rene Vega-Carrillo
EMEduardo Manzanares-Acuña
Eduardo Manzanares-Acuña
MIMaría Pilar Iñiguez
María Pilar Iñiguez
EGEduardo Gallego
Eduardo Gallego
ALAlfredo Lorente
Alfredo Lorente

13 September 2012 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
FSF Sánchez-Doblado
F Sánchez-Doblado
CDC Domingo
C Domingo
FGF Gómez
F Gómez
BSB Sánchez-Nieto
B Sánchez-Nieto
JMJ L Muñiz
J L Muñiz
FFF Fernández
F Fernández
Neutron peripheral contamination in patients undergoing high-energy photon radiotherapy is considered as a risk factor for secondary cancer induction. Organ-specific neutron-equivalent dose estimation is therefore essential for a reasonable assessment of these associated risks. This work aimed to develop a method to estimate neutron-equivalent doses in multiple organs of radiotherapy patients. The method involved the convolution, at 16 reference points in an anthropomorphic phantom, of the normalized Monte Carlo neutron fluence energy spectra with the kerma and energy-dependent radiation weighting factor. This was then scaled with the total neutron fluence measured with passive detectors, at the same reference points, in order to obtain the equivalent doses in organs. The latter were correlated with the readings of a neutron digital detector located inside the treatment room during phantom irradiation. This digital detector, designed and developed by our group, integrates the thermal neutron fluence. The correlation model, applied to the digital detector readings during patient irradiation, enables the online estimation of neutron-equivalent doses in organs. The model takes into account the specific irradiation site, the field parameters (energy, field size, angle incidence, etc) and the installation (linac and bunker geometry). This method, which is suitable for routine clinical use, will help to systematically generate the dosimetric data essential for the improvement of current risk-estimation models.

1 May 2010 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
JGJ. García
J. García
DBDaniele Baraldi
Daniele Baraldi
EGEduardo Gallego
Eduardo Gallego
ABA. Beccantini
A. Beccantini
ACA. Crespo
A. Crespo
EME. Migoya
E. Migoya