In this paper, a design method for a photovoltaic system based on a dual active bridge converter and a photovoltaic module is proposed. The method is supported by analytical results and theoretical predictions, which are confirmed with circuital simulations. The analytical development, the theoretical predictions, and the validation through circuital simulations, are the main contributions of the paper. The dual active bridge converter is selected due to its high efficiency, high input and output voltages range, and high voltage-conversion ratio, which enables the interface of low-voltage photovoltaic modules with a high-voltage dc bus, such as the input of a micro-inverter. To propose the design method, the circuital analysis of the dual active bridge converter is performed to describe the general waveforms derived from the circuit behavior. Then, the analysis of the dual active bridge converter, interacting with a photovoltaic module driven by a maximum power point tracking algorithm, is used to establish the mathematical expressions for the leakage inductor current, the photovoltaic current, and the range of operation for the phase shift. The design method also provides analytical equations for both the high-frequency transformer equivalent leakage inductor and the photovoltaic side capacitor. The design method is validated through detailed circuital simulations of the whole photovoltaic system, which confirm that the maximum power of the photovoltaic module can be extracted with a correct design of the dual active bridge converter. Also, the theoretical restrictions of the photovoltaic system, such as the photovoltaic voltage and power ripples, are fulfilled with errors lower than 2% with respect to the circuital simulations. Finally, the simulation results also demonstrate that the maximum power point for different environmental conditions is reached, optimizing the phase shift factor with a maximum power point tracking algorithm.
This study proposes a charging/discharging system of energy storage devices (ESDs) to regulate the voltage of a dc bus. The proposed charging/discharging system is formed by a zeta/sepic converter and a sliding mode controller (SMC). The SMC uses a single sliding surface to regulate the dc bus voltage for the three operating modes of the charger/discharger converter (charging, discharging, and stand‐by) and for ESD voltages lower, equal, or higher than the dc bus voltage. This study includes the stability analysis of the SMC and a design procedure of the SMC parameters. The charging/discharging system is simulated in PSIM, where the results confirm that the proposed SMC regulates the bus voltage in charging, discharging, and stand‐by modes for different operating points of the system. Finally, the proposed charging/discharging system was constructed for demonstrating the feasibility of the solution for real applications. Moreover, the experimental results obtained in such a platform put into evidence the accuracy of the proposed SMC in regulating the bus voltage in all the possible conditions: bus voltage lower, equal or higher than ESD voltage, and during charge, discharge, and stand‐by modes of the ESD.
27 April 2021 in International Journal of Circuit Theory and Applications
Due to the wide usability of thermoelectric generators (TEG) in the industry and research fields, it is plausible that mismatching conditions are present on the thermal surfaces of a TEG device, which induces negative-performance effects due to uneven surface temperature distributions. For this reason, the objective of this study is to characterize numerically the open-circuit electric output voltage of a TEG device when a mismatching condition is applied to both the cold and hot sides of the selected N and P-type semiconductor material . A validated numerical simulation paired with a parametric study is conducted using the Thermal-Electric module of ANSYS 2020 R1, for which different thermal boundary and mismatching conditions are applied while considering the temperature-dependent thermoelectrical properties of the N and P-type material. The results show an inverse relationship between the open-circuit voltage and the mismatching temperature difference. When a mismatching condition is applied on the hot side of the TEG device, the temperature-dependent electrical resistance has lower values, deriving in higher voltage results (linear tendency) compared to a mismatching condition applied to the cold side (non-linear tendency).
Dual active bridge converters (DAB) are used to interconnect photovoltaic (PV) generators with AC and DC buses or isolated loads. However, a controller is needed to provide a stable and efficient operation of the DAB converter when the PV generator must be interconnected with a DC bus, which is particularly important in microinverter applications. Therefore, this paper proposes the design of a cascade controller for a PV system based on a DAB converter. The converter is controlled using a peak current control and an adaptive PI voltage control; thus the methodology to design the cascade controller is developed in two steps; first, the PV system formed by a PV generator, a DAB converter, and an inverter or load is introduced, including the description of the leakage current; as a second step, the model of the PV system to design the cascade controller is presented. Then, a relationship between the phase shift factor and the peak current of the leakage inductor is derived, which is used to design the peak current controller to ensure the DAB converter operation at the most efficient operating condition. On the other hand, an adaptive PI controller for the PV voltage is designed to ensure the reference tracking provided by a maximum power point (MPP) algorithm. The effectiveness of the proposed cascade controller is demonstrated through realistic examples simulated in PSIM. The power and control circuits implemented in PSIM are presented to encourage the use of the proposed solution. The simulation results confirm the correct operation of the control system, which mitigates the oscillatory perturbation produced by an inverter connected to the PV system, and also ensures the maximum power extraction from the PV panel by following the MPP reference.
Solar energy is a source of sustainable energy and its optimal use depends on the efficiency and reliability of PV systems. Dual active bridge converters are a solution to interface PV modules with the grid or high voltage requirement applications due to the high voltage-conversion-ratio and high efficiency provided by such a converter. The three main contributions of this work are: an extensive mathematical model of a DAB converter connected to a PV module including protection diodes, which is intended to design non-linear controllers, an explicit linearized version of the model, which is oriented to design traditional control systems; and a detailed and replicable application example of the model focused on maximizing the power extraction from a PV system. The modeling approach starts with the differential equations of the PV system; however, only the fundamental and average components of each signal is used to represent it. The control-oriented model is validated using a detailed circuital simulation. First, through the comparison of frequency and time diagrams of the proposed model and a detailed one; and then, through the simulation of the PV system in a realistic application case. PV voltage regulation and maximum power extraction are confirmed in simulation results.