Emanuele Buchicchio

Dr. Emanuele Buchicchio

Department of Engineering, University of Perugia, Perugia, Umbria, Italy
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2023 in Energy
Verified
Journal Article
Open access
EBEmanuele Buchicchio
Emanuele Buchicchio
Alessio De AngelisAlessio De Angelis
Alessio De Angelis
Francesco SantoniFrancesco Santoni
Francesco Santoni
PCPaolo Carbone
Paolo Carbone
Francesco BianconiFrancesco Bianconi
Francesco Bianconi
FSFabrizio Smeraldi
Fabrizio Smeraldi

4 March 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Alessio De AngelisAlessio De Angelis
Alessio De Angelis
EBEmanuele Buchicchio
Emanuele Buchicchio
Francesco SantoniFrancesco Santoni
Francesco Santoni
Antonio  MoschittaAntonio Moschitta
Antonio Moschitta
PCPaolo Carbone
Paolo Carbone
Electrochemical impedance spectroscopy (EIS) is of fundamental importance for characterization and monitoring of rechargeable batteries in automotive, energy storage, and electronics sectors. In this article, a low-complexity practical system for EIS of batteries is presented, and the uncertainty associated with its measurement results is analyzed. The system is based on a voltage-controlled current generator and the acquisition of current and voltage signals from the battery under test. Arbitrary current waveforms can be generated, and thus the system is flexible and reconfigurable. In particular, a broadband multisine excitation signal is used, enabling faster measurements with respect to the conventional stepped sine approach. The proposed system is characterized by repeated measurements on a 18 650 lithium-ion battery. Moreover, it is validated by comparison with a commercial benchtop instrument, and with the ground truth provided by a discrete component Randles circuit. Results show that the system is able to accurately and repeatably measure the impedance of a battery in a wide frequency range from 0.05 Hz to 1 kHz. Furthermore, it provides results that are consistent with the commercial instrument and with the ground truth of the $R$ – $C$ Randles circuit. Therefore, the proposed system using the broadband multisine method is suitable for implementing fast and inexpensive monitoring capabilities in smart battery management systems.

22 July 2023 in Measurement
Verified
Journal Article
Open access
EBEmanuele Buchicchio
Emanuele Buchicchio
AAAlessio De Angelis
Alessio De Angelis
FSFrancesco Santoni
Francesco Santoni
PCPaolo Carbone
Paolo Carbone

17 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MRMatteo Rinalduzzi
Matteo Rinalduzzi
Alessio De AngelisAlessio De Angelis
Alessio De Angelis
Francesco SantoniFrancesco Santoni
Francesco Santoni
EBEmanuele Buchicchio
Emanuele Buchicchio
Antonio  MoschittaAntonio Moschitta
Antonio Moschitta
Mauro SerpelloniMauro Serpelloni
Mauro Serpelloni
Hand gesture recognition is a crucial task for the automated translation of sign language, which enables communication for the deaf. This work proposes the usage of a magnetic positioning system for recognizing the static gestures associated with the sign language alphabet. In particular, a magnetic positioning system, which is comprised of several wearable transmitting nodes, measures the 3D position and orientation of the fingers within an operating volume of about 30 × 30 × 30 cm, where receiving nodes are placed at known positions. Measured position data are then processed by a machine learning classification algorithm. The proposed system and classification method are validated by experimental tests. Results show that the proposed approach has good generalization properties and provides a classification accuracy of approximately 97% on 24 alphabet letters. Thus, the feasibility of the proposed gesture recognition system for the task of automated translation of the sign language alphabet for fingerspelling is proven.

1 July 2021
Verified
Conference Paper
Closed access
AAAlessio De Angelis
Alessio De Angelis
EBEmanuele Buchicchio
Emanuele Buchicchio
FSFrancesco Santoni
Francesco Santoni
AMAntonio Moschitta
Antonio Moschitta
PCPaolo Carbone
Paolo Carbone
In this paper, a low-complexity practical system for electrochemical impedance spectroscopy of batteries is presented. The system is based on a voltage-controlled current generator and on the acquisition of current and voltage signals from the battery under test. Arbitrary current waveforms can be generated, thus the system is flexible and reconfigurable. In particular, a broadband multisine excitation signal is used, enabling faster measurements with respect to the conventional stepped-sine approach. The multisine method and the stepped-sine method are compared using the proposed system. Furthermore, the proposed system is characterized by repeated measurements on a 18650 lithium-ion battery and by comparison with a commercial benchtop instrument. Results show that the system is able to accurately and repeatably measure the impedance of a battery in a wide frequency range from 0.05 Hz to 1 kHz. Furthermore, it provides results that are consistent with the commercial instrument.

11 September 2022 in Data in Brief
Verified
Journal Article
Open access
EBEmanuele Buchicchio
Emanuele Buchicchio
Alessio De AngelisAlessio De Angelis
Alessio De Angelis
Francesco SantoniFrancesco Santoni
Francesco Santoni
PCPaolo Carbone
Paolo Carbone
Francesco BianconiFrancesco Bianconi
Francesco Bianconi
FSFabrizio Smeraldi
Fabrizio Smeraldi
This dataset consists of electrochemical impedance spectroscopy measurements on commonly-used batteries, namely Samsung ICR18650-26J cylindrical Lithium-Ion cells. The complex impedance of the batteries was measured at a set of fourteen different frequencies from 0.05 Hz to 1000 Hz, using a random-phase multi-sine excitation signal. For each excited frequency, the current amplitude was 50 mA, resulting in a measurement uncertainty of approximately 0.1 mΩ.