Paolo Carbone

Dr. Paolo Carbone

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2023 in Energy
Verified
Journal Article
Open access
EBEmanuele Buchicchio
Emanuele Buchicchio
Alessio De AngelisAlessio De Angelis
Alessio De Angelis
Francesco SantoniFrancesco Santoni
Francesco Santoni
PCPaolo Carbone
Paolo Carbone
Francesco BianconiFrancesco Bianconi
Francesco Bianconi
FSFabrizio Smeraldi
Fabrizio Smeraldi

17 January 2024 in Journal of Energy Storage
Verified
Journal Article
Open access
Francesco SantoniFrancesco Santoni
Francesco Santoni
AAAlessio De Angelis
Alessio De Angelis
AMAntonio Moschitta
Antonio Moschitta
PCPaolo Carbone
Paolo Carbone
MGMatteo Galeotti
Matteo Galeotti
ACAldo Di Carlo
Aldo Di Carlo

1 June 1994 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
PCPaolo Carbone
Paolo Carbone
DPDario Petri
Dario Petri

31 December 2014 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Guido De AngelisGuido De Angelis
Guido De Angelis
VPValter Pasku
Valter Pasku
Alessio De AngelisAlessio De Angelis
Alessio De Angelis
MDMarco Dionigi
Marco Dionigi
MMMauro Mongiardo
Mauro Mongiardo
PCPaolo Carbone
Paolo Carbone
This paper describes the design and realization of a magnetic indoor positioning system. The system is entirely realized using off-the-shelf components and is based on inductive coupling between resonating coils. Both system-level architecture and realization details are described along with experimental results. The realized system exhibits a maximum positioning error of <;10 cm in an indoor environment over a 3 × 3 m 2 area. Extensive experiments in larger areas, in nonline-of-sight conditions, and in unfavorable geometric configurations, show submeter accuracy, thus validating the robustness of the system with respect to other existing solutions.

19 May 2015 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Alessio De AngelisAlessio De Angelis
Alessio De Angelis
Antonio  MoschittaAntonio Moschitta
Antonio Moschitta
PCPaolo Carbone
Paolo Carbone
MCMassimo Calderini
Massimo Calderini
SNStefano Neri
Stefano Neri
MPManuelo Peppucci
Manuelo Peppucci
In this paper, an ultrasonic positioning system is presented and characterized, based on the usage of a portable grid of beacons and of a few fixed anchors. Since the beacon grid can be moved to guarantee line-of-sight transmissions, the proposed strategy is potentially suitable for accurate positioning of a mobile object in an environment with a complex geometry. The system was tested experimentally, exhibiting a subcentimeter positioning accuracy in a range up to 4 m.

15 October 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Marco CrescentiniMarco Crescentini
Marco Crescentini
Alessio De AngelisAlessio De Angelis
Alessio De Angelis
RRRoberta Ramilli
Roberta Ramilli
Guido De AngelisGuido De Angelis
Guido De Angelis
MTMarco Tartagni
Marco Tartagni
PCPaolo Carbone
Paolo Carbone
This article presents a compact measurement system for electrochemical impedance spectroscopy (EIS) on lithium-ion battery (LIB). The system is composed of a vector impedance analyzer (VIA) and state parameter estimation. The VIA architecture is based on delta-sigma digital-to-analog and analog-to-digital conversions to achieve the compactness, low-power consumption, and high resolution required to be potentially integrated within a battery cell. The estimation of state parameters is based on equivalent circuit models and the solution of nonlinear optimization problems. The proposed measurement system aims at the integration of complex measurement features directly into the battery cell to allow online and real-time diagnostic of the battery cell. A prototype of the compact measurement system was realized to assess the proposed approach. Experimental results are provided and validated by comparison with a reference laboratory instrument, showing good agreement. The VIA prototype is experimentally tested in both the online monitoring and aging monitoring of a commercial LIR2032 LIB cell. The modeling approach is applied to the experimental data provided by the VIA prototype, showing a good fit of the data. Moreover, parameters of the equivalent circuit models are extracted from the experimental data provided by the VIA prototype and identify trends related to the state of charge of the battery.