Francesco Santoni

Dr. Francesco Santoni

Università degli Studi di Perugia - Department of Engineering
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2023 in Energy
Verified
Journal Article
Open access
EBEmanuele Buchicchio
Emanuele Buchicchio
Alessio De AngelisAlessio De Angelis
Alessio De Angelis
Francesco SantoniFrancesco Santoni
Francesco Santoni
PCPaolo Carbone
Paolo Carbone
Francesco BianconiFrancesco Bianconi
Francesco Bianconi
FSFabrizio Smeraldi
Fabrizio Smeraldi

17 January 2024 in Journal of Energy Storage
Verified
Journal Article
Open access
Francesco SantoniFrancesco Santoni
Francesco Santoni
AAAlessio De Angelis
Alessio De Angelis
AMAntonio Moschitta
Antonio Moschitta
PCPaolo Carbone
Paolo Carbone
MGMatteo Galeotti
Matteo Galeotti
ACAldo Di Carlo
Aldo Di Carlo

16 May 2016 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GNGang Niu
Gang Niu
PCPauline Calka
Pauline Calka
MMMatthias Auf der Maur
Matthias Auf der Maur
Francesco SantoniFrancesco Santoni
Francesco Santoni
SGSubhajit Guha
Subhajit Guha
TSThomas Schroeder
Thomas Schroeder
Filament-type HfO2-based RRAM has been considered as one of the most promising candidates for future non-volatile memories. Further improvement of the stability, particularly at the “OFF” state, of such devices is mainly hindered by resistance variation induced by the uncontrolled oxygen vacancies distribution and filament growth in HfO2films. We report highly stable endurance of TiN/Ti/HfO2/Si-tip RRAM devices using a CMOS compatible nanotip method. Simulations indicate that the nanotip bottom electrode provides a local confinement for the electrical field and ionic current density; thus a nano-confinement for the oxygen vacancy distribution and nano-filament location is created by this approach. Conductive atomic force microscopy measurements confirm that the filaments form only on the nanotip region. Resistance switching by using pulses shows highly stable endurance for both ON and OFF modes, thanks to the geometric confinement of the conductive path and filament only above the nanotip. This nano-engineering approach opens a new pathway to realize forming-free RRAM devices with improved stability and reliability.

4 March 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Alessio De AngelisAlessio De Angelis
Alessio De Angelis
EBEmanuele Buchicchio
Emanuele Buchicchio
Francesco SantoniFrancesco Santoni
Francesco Santoni
Antonio  MoschittaAntonio Moschitta
Antonio Moschitta
PCPaolo Carbone
Paolo Carbone
Electrochemical impedance spectroscopy (EIS) is of fundamental importance for characterization and monitoring of rechargeable batteries in automotive, energy storage, and electronics sectors. In this article, a low-complexity practical system for EIS of batteries is presented, and the uncertainty associated with its measurement results is analyzed. The system is based on a voltage-controlled current generator and the acquisition of current and voltage signals from the battery under test. Arbitrary current waveforms can be generated, and thus the system is flexible and reconfigurable. In particular, a broadband multisine excitation signal is used, enabling faster measurements with respect to the conventional stepped sine approach. The proposed system is characterized by repeated measurements on a 18 650 lithium-ion battery. Moreover, it is validated by comparison with a commercial benchtop instrument, and with the ground truth provided by a discrete component Randles circuit. Results show that the system is able to accurately and repeatably measure the impedance of a battery in a wide frequency range from 0.05 Hz to 1 kHz. Furthermore, it provides results that are consistent with the commercial instrument and with the ground truth of the $R$ – $C$ Randles circuit. Therefore, the proposed system using the broadband multisine method is suitable for implementing fast and inexpensive monitoring capabilities in smart battery management systems.

21 February 2015 in Journal of Polymer Science Part B: Polymer Physics
Verified
Journal Article
Closed access
PDF file
AZAndrea Zampetti
Andrea Zampetti
AFAmir Hossein Fallahpour
Amir Hossein Fallahpour
MDMartina Dianetti
Martina Dianetti
LSLuigi Salamandra
Luigi Salamandra
Francesco SantoniFrancesco Santoni
Francesco Santoni
Aldo Di CarloAldo Di Carlo
Aldo Di Carlo

16 August 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
RRRoberta Ramilli
Roberta Ramilli
Francesco SantoniFrancesco Santoni
Francesco Santoni
Alessio De AngelisAlessio De Angelis
Alessio De Angelis
Marco CrescentiniMarco Crescentini
Marco Crescentini
PCPaolo Carbone
Paolo Carbone
PTPier Andrea Traverso
Pier Andrea Traverso
Online diagnostic of lithium-ion battery (LIB) cells may have significant impact on chemical energy storage systems. Electrochemical impedance spectroscopy (EIS) is widely used for the characterization of LIBs and could be the most appropriate technique for online diagnostic, but its response time should be shortened. This work investigates the usage of multisine excitation to shorten the measurement time and simplify the hardware implementation for EIS of battery cells. Two types of multisine binary sequences are considered: sigma–delta modulated multisine sequences (SDMSs) and maximum length binary sequences (MLBSs). Their applicability to online and in situ EIS monitoring is evaluated by designing a measurement architecture also suitable to be implemented in a system-on-chip. The calibrated measurement system is compared with a benchtop reference instrument, reporting an RMSE deviation smaller than 5% in the frequency range of interest 1–200 Hz. The realized system is then used for online monitoring of the discharge process of a commercial 18650 LIB cell. The two proposed sequences are compared in terms of accuracy using a digital battery emulator circuit. Both the sequences demonstrated to be suitable for fast measurement and simple hardware integration, enabling online in situ EIS monitoring at cell level.