Emanuil Parunakian

Mr. Emanuil Parunakian

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2024 in Ophthalmology
Verified
Journal Article
Closed access
SUShoaib Ugradar
Shoaib Ugradar
EPEmanuil Parunakian
Emanuil Parunakian
EMEmil Malkhasyan
Emil Malkhasyan
CCCarolina A. Chiou
Carolina A. Chiou
HWHannah L. Walsh
Hannah L. Walsh
RDRaymond S. Douglas
Raymond S. Douglas

23 December 2024 in Ophthalmic Plastic & Reconstructive Surgery
Verified
Journal Article
Closed access
SUShoaib Ugradar
Shoaib Ugradar
EPEmanuil Parunakian
Emanuil Parunakian
EZErin B.S. Zimmerman
Erin B.S. Zimmerman
EMEmil B.S. Malkhasyan
Emil B.S. Malkhasyan
PRPershanjit M.B.B.S. Raika
Pershanjit M.B.B.S. Raika
RDRaymond S. M.D. Douglas
Raymond S. M.D. Douglas
Purpose: Teprotumumab, a novel human monoclonal antibody, has been shown to reverse the clinical manifestations of thyroid eye disease. Previous reports have suggested that it demonstrates disease-modifying properties through the reduction of orbital fat and muscle volumes. This study aims to analyze orbital volumetric change following treatment and to identify clinical and radiological predictors of response. Methods: This was a prospective longitudinal study with 35 consecutive patients who had available pre- and posttreatment orbital imaging. Three-dimensional volumetric calculations of orbital fat, extraocular muscles, and proptosis were measured using previously validated image processing software. This information was used with demographic data to create a multivariate regression model to review which baseline clinical or radiological factors were predictors of proptosis response. Results: In the study orbit, 20 patients (57%) had a proptosis reduction of ≥2 mm. In the fellow orbit, 18 patients (51%) had a proptosis reduction of ≥2 mm. Regression modeling revealed that baseline proptosis and baseline muscle volumes were significant predictors of proptosis response (p < 0.01 and p < 0.05, respectively). Further, changes in muscle volume and fat volume were significantly associated with proptosis response (r = 0.5, p < 0.001 and r = 0.3, p = 0.012, respectively). Conclusion: Teprotumumab significantly reduces orbital fat and muscle volumes. This is manifested by a significant reduction in proptosis. Baseline proptosis and muscle volumes are significant predictors of proptosis response.

12 August 2025 in American Journal of Ophthalmology
Verified
Journal Article
Open access
VYVeronika Yehezkeli
Veronika Yehezkeli
EPEmanuil Parunakian
Emanuil Parunakian
SSSoh Youn Suh
Soh Youn Suh
QMQingyu Meng
Qingyu Meng
Joseph Louis DemerJoseph Louis Demer
Joseph Louis Demer
Consensus is lacking around optimal surgical strategies to correct V-pattern exotropia (VXT). This study quantitatively examined alternative surgical strategies and dosing . Comparative interventional case series. Consecutive patients with VXT undergoing strabismus surgery between 2014 and 2025 were reviewed. Incomitance of at least 15D between sursumversion and deorsumversion was considered V-pattern. Surgeries were performed by 2 surgeons using identical technique. The primary outcome was the surgical alignment effect. A total of 55 patients (36 children and 19 adults) underwent horizontal rectus muscle surgery: inferior oblique (IO) recession (n = 12), superior transposition of lateral rectus muscles (n = 20), their combination (n = 10), and no modifications (n = 13). Surgery reduced average primary gaze exotropia in all groups from 29 ± 11Δ to 8 ± 8Δ (SD P < .001), irrespective of pattern collapse. There was 6.0 Δ mean postoperative exodrift after 2.1 ± 2.0 years following surgery. Pattern decreased in all groups from: 22 ± 8Δ to 10 ± 8Δ by IO recession, 22 ± 6Δ to 3 ± 6Δ by horizontal rectus transposition, 30 ± 10Δ to 5 ± 13Δ by the combination, and 16 ± 2Δ to 6 ± 7Δ with no modifications. The combined procedure yielded the greatest pattern reduction. Transpositions of half and three-quarter tendon width yielded similar effects on pattern. Linear regression showed a significant correlation between lateral rectus recession and exotropia reduction (P < .001), accounting for 40% of variance. However, the surgical effect was smaller than that predicted by Parks tables. IO recession, LR transposition, and their combination reduce pattern in VXT, with the greatest effect when combined. Horizontal rectus recession alone also reduces the pattern, albeit to a lesser extent. Horizontal rectus recession dose need not be adjusted for pattern collapse. Early overcorrection is recommended.

25 August 2025 in American Journal of Ophthalmology
Verified
Journal Article
Open access
QMQingyu Meng
Qingyu Meng
EPEmanuil Parunakian
Emanuil Parunakian
VYVeronika Yehezkeli
Veronika Yehezkeli
Joseph Louis DemerJoseph Louis Demer
Joseph Louis Demer
Because surgical tables have not previously been available for consecutive exotropia, this study aimed to determine the appropriate surgical dosing for medial rectus (MR) advancement in this condition. Retrospective case series. Data were reviewed for patients with consecutive exotropia who underwent MR advancement with or without lateral rectus (LR) recession. A total of 44 patients were included averaging 35 ± 20 (stamdard deviation ) years of age. Mean preoperative exotropia was 29 ± 15∆ at distance and 33 ± 19∆ at near. Thirty-four patients underwent unilateral or bilateral MR advancement, and 10 patients underwent MR advancement combined with LR recession. For the MR advancement group, mean advancement was 4.9 ± 1.4 mm. At the last follow-up visit, exotropia at distance was reduced from 26 ± 12∆ to 7 ± 11∆. For the MR advancement + LR recession group, mean MR advancement was 6.2 ± 2.0 mm, and the mean total surgical dose, including LR recession, was 14.6 ± 4.7 mm. Overall, distance exotropia at last follow-up was surgically reduced from 39 ± 18∆ to 9 ± 14∆. Exodrift from initial to final follow-up was 6.6∆ for MR advancement alone and 7.5∆ for MR advancement + LR recession. Regression analysis of surgical dose-response suggests that each MR advancement should be augmented by 2 mm more than Parks' general surgical recommendation for treating exotropia by MR resection. Augmentation of MR advancement may improve the correction of consecutive exotropia and is effective while affording opportunity to explore the MR muscle.

16 September 2026 in American Journal of Ophthalmology
Verified
Journal Article
Open access
SNSebastiano Nunziata
Sebastiano Nunziata
VYVeronika Yehezkeli
Veronika Yehezkeli
EPEmanuil Parunakian
Emanuil Parunakian
Joseph Louis DemerJoseph Louis Demer
Joseph Louis Demer

24 June 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
EPEmanuil Parunakian
Emanuil Parunakian
ASAtharva Shetye
Atharva Shetye
VYVeronika Yehezkeli
Veronika Yehezkeli
SJSomaye Jafari
Somaye Jafari
Joseph Louis DemerJoseph Louis Demer
Joseph Louis Demer
Ocular ductions deform the optic disc and peripapillary blood vessels, and deformations can be interpreted as mechanical strain. We used confocal scanning laser ophthalmoscopy (cSLO) to map strain in disc and peripapillary retinal vessels associated with the cardiac pulse and determine if such strain is influenced by gaze direction. Sets of 13 infrared cSLO images were obtained sequentially for each eye using a Heidelberg Spectralis scanner in cinematic mode over a 3 sec interval in adults. Imaging was repeated in central, and horizontally (30° adduction/abduction) and vertically eccentric gazes (10° supraduction/infraduction). Retinal vessels, optic disc, and fovea were segmented using custom-trained, deep learning-based models. Frame to frame vascular displacements were automatically determined using optical flow analysis, allowing computation of equivalent strain. A total of 25 eyes of 13 subjects of mean age 39 ± 18 (standard deviation, range: 25 to 81) years were included. Average equivalent strain over 3 sec ranging from 0.27% to 0.36% exceeded the 0.16% noise threshold across all gazes and regions, indicating measurable pulse-induced deformation. After adjustment for age and axial length, pulsatile maximum and minimum strain were influenced slightly by gaze direction, maximally for supraduction, whereas mean strain did not vary significantly with gaze. The cardiac pulse induces measurable deformation of retinal vessels that can be quantified as equivalent strain in the image plane using optical flow-derived displacement fields. However, the interaction of pulse strain with gaze direction is unlikely to be a significant confound for investigations of strains associated with eye movements.