Somaye Jafari

Dr. Somaye Jafari

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2021 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
JPJoseph Park
Joseph Park
ASAndrew Shin
Andrew Shin
SJSomaye Jafari
Somaye Jafari
Joseph Louis DemerJoseph Louis Demer
Joseph Louis Demer
The optic nerve (ON) is a recently recognized tractional load on the eye during larger horizontal eye rotations. In order to understand the mechanical behavior of the eye during adduction, it is necessary to characterize material properties of the sclera, ON, and in particular its sheath. We performed tensile loading of specimens taken from fresh postmortem human eyes to characterize the range of variation in their biomechanical properties and determine the effect of preconditioning. We fitted reduced polynomial hyperelastic models to represent the nonlinear tensile behavior of the anterior, equatorial, posterior, and peripapillary sclera, as well as the ON and its sheath. For comparison, we analyzed tangent moduli in low and high strain regions to represent stiffness. Scleral stiffness generally decreased from anterior to posterior ocular regions. The ON had the lowest tangent modulus, but was surrounded by a much stiffer sheath. The low-strain hyperelastic behaviors of adjacent anatomical regions of the ON, ON sheath, and posterior sclera were similar as appropriate to avoid discontinuities at their boundaries. Regional stiffnesses within individual eyes were moderately correlated, implying that mechanical properties in one region of an eye do not reliably reflect properties of another region of that eye, and that potentially pathological combinations could occur in an eye if regional properties are discrepant. Preconditioning modestly stiffened ocular tissues, except peripapillary sclera that softened. The nonlinear mechanical behavior of posterior ocular tissues permits their stresses to match closely at low strains, although progressively increasing strain causes particularly great stress in the peripapillary region.

28 February 2024 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
SJSomaye Jafari
Somaye Jafari
JPJoseph Park
Joseph Park
Yongtao LuYongtao Lu
Yongtao Lu
Joseph Louis DemerJoseph Louis Demer
Joseph Louis Demer
Details of the anatomy and behavior of the structures responsible for human eye movements have been extensively elaborated since the first modern biomechanical models were introduced. Based on these findings, a finite element model of human ocular adduction is developed based on connective anatomy and measured optic nerve (ON) properties, as well as active contractility of bilaminar extraocular muscles (EOMs), but incorporating the novel feature that globe translation is not otherwise constrained so that realistic kinematics can be simulated. Anatomy of the hemisymmetric model is defined by magnetic resonance imaging. The globe is modeled as suspended by anatomically realistic connective tissues, orbital fat, and contiguous ON. The model incorporates a material subroutine that implements active EOM contraction based on fiber twitch characteristics. Starting from the initial condition of 26° adduction, the medial rectus (MR) muscle was commanded to contract as the lateral rectus (LR) relaxed. We alternatively modeled absence or presence of orbital fat. During pursuit-like adduction from 26 to 32°, the globe translated 0.52 mm posteriorly and 0.1 mm medially with orbital fat present, but 1.2 mm posteriorly and 0.1 mm medially without fat. Maximum principal strains in the optic disk and peripapillary reached 0.05–0.06, and von-Mises stress 96 kPa. Tension in the MR orbital layer was ~ 24 g-force after 6° adduction, but only ~ 3 gm-f in the whole LR. This physiologically plausible simulation of EOM activation in an anatomically realistic globe suspensory system demonstrates that orbital connective tissues and fat are integral to the biomechanics of adduction, including loading by the ON.

8 August 2024 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
JPJoseph Park
Joseph Park
ILImmi Lee
Immi Lee
SJSomaye Jafari
Somaye Jafari
Joseph Louis DemerJoseph Louis Demer
Joseph Louis Demer
We characterized the tensile behavior of sclera, optic nerve (ON), and ON sheath in eyes from donors with glaucoma, for comparison with published data without glaucoma. Twelve freshly harvested eyes were obtained from donors with history of glaucoma, of average age 86 ± 7 (standard deviation) years. Rectangular samples were taken from anterior, equatorial, posterior, and peripapillary sclera, and ON sheath, while ON was in native form and measured using calipers. Under physiological temperature and humidity, tissues were preconditioned at 5% strain before loading at 0.1 mm/s. Force–displacement data were converted into engineering stress–strain curves fit by reduced polynomial hyperelastic models and analyzed by tangent moduli at 3% and 7% strain. Data were compared with an age-matched sample of 7 published control eyes. Optic atrophy was supported by significant reduction in ON cross section to 73% of normal in glaucomatous eyes. Glaucomatous was significantly stiffer than control in equatorial and peripapillary regions (P < 0.001). However, glaucomatous ON and sheath were significantly less stiff than control, particularly at low strain (P < 0.001). Hyperelastic models were well fit to stress–strain data (R2 > 0.997). Tangent moduli had variability similar to control in most regions, but was abnormally large in peripapillary sclera. Tensile properties were varied independently among various regions of the same eyes. Glaucomatous sclera is abnormally stiff, but the ON and sheath are abnormally compliant. These abnormalities correspond to properties predicted by finite element analysis to transfer potentially pathologic stress to the vulnerable disk and lamina cribrosa region during adduction eye movement.

29 May 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
SJSomaye Jafari
Somaye Jafari
SCShengqiang Cai
Shengqiang Cai
Joseph Louis DemerJoseph Louis Demer
Joseph Louis Demer
Previous models of extraocular mechanics have often assumed isotropic properties for ocular tissues, despite evidence indicating anisotropy in the optic nerve sheath (ONS). To investigate this further, we developed a finite element model (FEM) of horizontal eye rotation using MRI data from a living subject with normal tension glaucoma. Mechanical properties were derived from tensile tests on 17 post-mortem human eyes, revealing previously unrecognized anisotropic characteristics in the ONS. We simulated ±32° horizontal eye rotations and compared isotropic versus anisotropic ONS properties using the Holzapfel model. Strain distributions in the optic nerve (ON) were analyzed using ABAQUS 2024 software. During 32° adduction, stress and strain were concentrated at the ONS-sclera junction, reaching 8 MPa and 40% with isotropic properties, and 15 MPa and 30% with anisotropic properties. In contrast, during 32° abduction, stress was lower and strain was higher in the isotropic case (6 MPa and 30%) compared to the anisotropic case (12 MPa and 25%). Increased intraocular and intracranial pressures had minimal impact on the mechanical responses. These findings suggest that the anisotropic properties of the ONS increase stress concentration at the optic disc while reducing strain during eye movements, offering new insights into ocular biomechanics. A novel phenomenon emerged from the simulations: during larger ductions, the peripapillary Bruch’s membrane is predicted to wrinkle, forming undulations with an approximately 20 μm amplitude and 100 μm wavelength at its interface with the retina and choroid.

2 May 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
SLSeongjin Lim
Seongjin Lim
CKChangzoo Kim
Changzoo Kim
SJSomaye Jafari
Somaye Jafari
JPJoseph Park
Joseph Park
SGStephanie S. Garcia
Stephanie S. Garcia
Joseph Louis DemerJoseph Louis Demer
Joseph Louis Demer
Postmortem human eyes were subjected to optic nerve (ON) traction in adduction and elevated intraocular pressure (IOP) to investigate scleral surface deformations. We incrementally adducted 11 eyes (age 74.1 ± 9.3 years, standard deviation) from 26° to 32° under normal IOP, during imaging of the posterior globe, for analysis by three-dimensional digital image correlation (3D-DIC). In the same eyes, we performed uniaxial tensile testing in multiple regions of the sclera, ON, and ON sheath. Based on individual measurements, we analyzed eye-specific finite element models (FEMs) simulating adduction and IOP loading. Analysis of 3D-DIC showed that the nasal sclera up to 1 mm from the sheath border was significantly compressed during adduction. IOP elevation from 15 to 30 mmHg induced strains less than did adduction. Tensile testing demonstrated ON sheath stiffening above 3.4% strain, which was incorporated in FEMs of adduction tethering that was quantitatively consistent with changes in scleral deformation from 3D-DIC. Simulated IOP elevation to 30 mmHg did not induce scleral surface strains outside the ON sheath. ON tethering in incremental adduction from 26° to 32° compressed the nasal and stretched the temporal sclera adjacent to the ON sheath, more so than IOP elevation. The effect of ON tethering is influenced by strain stiffening of the ON sheath.

24 June 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
EPEmanuil Parunakian
Emanuil Parunakian
ASAtharva Shetye
Atharva Shetye
VYVeronika Yehezkeli
Veronika Yehezkeli
SJSomaye Jafari
Somaye Jafari
Joseph Louis DemerJoseph Louis Demer
Joseph Louis Demer
Ocular ductions deform the optic disc and peripapillary blood vessels, and deformations can be interpreted as mechanical strain. We used confocal scanning laser ophthalmoscopy (cSLO) to map strain in disc and peripapillary retinal vessels associated with the cardiac pulse and determine if such strain is influenced by gaze direction. Sets of 13 infrared cSLO images were obtained sequentially for each eye using a Heidelberg Spectralis scanner in cinematic mode over a 3 sec interval in adults. Imaging was repeated in central, and horizontally (30° adduction/abduction) and vertically eccentric gazes (10° supraduction/infraduction). Retinal vessels, optic disc, and fovea were segmented using custom-trained, deep learning-based models. Frame to frame vascular displacements were automatically determined using optical flow analysis, allowing computation of equivalent strain. A total of 25 eyes of 13 subjects of mean age 39 ± 18 (standard deviation, range: 25 to 81) years were included. Average equivalent strain over 3 sec ranging from 0.27% to 0.36% exceeded the 0.16% noise threshold across all gazes and regions, indicating measurable pulse-induced deformation. After adjustment for age and axial length, pulsatile maximum and minimum strain were influenced slightly by gaze direction, maximally for supraduction, whereas mean strain did not vary significantly with gaze. The cardiac pulse induces measurable deformation of retinal vessels that can be quantified as equivalent strain in the image plane using optical flow-derived displacement fields. However, the interaction of pulse strain with gaze direction is unlikely to be a significant confound for investigations of strains associated with eye movements.