Eyad A. Feilat

Prof. Dr. Eyad A. Feilat

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2011 in Soft Computing
Verified
Journal Article
Closed access
PDF file
MJMohammad A. Jaradat
Mohammad A. Jaradat
MGMohammad H. Garibeh
Mohammad H. Garibeh
Eyad A. FeilatEyad A. Feilat
Eyad A. Feilat

1 January 2018 in Sustainable Cities and Society
Verified
Journal Article
Closed access
Eyad A. FeilatEyad A. Feilat
Eyad A. Feilat
SAS. Azzam
S. Azzam
AAA. Al-Salaymeh
A. Al-Salaymeh

13 September 2017 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
IMIbrahim A. Metwally
Ibrahim A. Metwally
MEMohamed Eladawy
Mohamed Eladawy
Eyad A. FeilatEyad A. Feilat
Eyad A. Feilat
Surge arresters play an important role in maintaining the reliability and protection of the high voltage power systems. Various diagnostic online monitoring methods of surge arrester are based on the decomposition of the measured leakage current into their capacitive and resistive components. The arrester's resistive component of the leakage current, in particular, the third harmonic component, is known as to be directly related to the degree of degradation of the ZnO blocks. This paper proposes an online monitoring technique for the surge arrester under dry and pollution conditions when measuring either the total leakage current or both the internal and external leakage currents of three different types of surge arresters. This technique based on feature extraction of the magnitudes, frequencies, and phase angles of all frequency components of the real measured current signals using Prony analysis-Hilbert transform approach and MATLAB program. The observed results illustrate the viability of this technique for online monitoring of surge arrester. Furthermore, the effect of voltage harmonics on the measured leakage currents is investigated through surge arrester model simulation performed with PSCAD program.

2 October 2006 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Eyad A. FeilatEyad A. Feilat
Eyad A. Feilat
This letter presents an efficient method for the detection of the instantaneous flicker level. The technique is based on extracting the magnitudes, frequencies, and phase angles of all frequency components of the voltage envelope using Prony analysis. By reconstructing the voltage waveform as linear combination of sinusoids, Hilbert transform can be applied to the predicted signal to develop the envelope of the voltage waveform. Two cases of flicker with single low frequency and wide band frequency interharmonics are investigated using simulated voltage signals. Simulation results are discussed

1 January 1992 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
ASA.A. Shaltout
A.A. Shaltout
Eyad A. FeilatEyad A. Feilat
Eyad A. Feilat

1 March 1994 in Electric Power Systems Research
Verified
Journal Article
Closed access
Eyad A. FeilatEyad A. Feilat
Eyad A. Feilat
IEIbrahim El-Amin
Ibrahim El-Amin
MBMaamar Bettayeb
Maamar Bettayeb