Mohamed Eladawy

Prof. Mohamed Eladawy

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2017 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
IMIbrahim A. Metwally
Ibrahim A. Metwally
MEMohamed Eladawy
Mohamed Eladawy
Eyad A. FeilatEyad A. Feilat
Eyad A. Feilat
Surge arresters play an important role in maintaining the reliability and protection of the high voltage power systems. Various diagnostic online monitoring methods of surge arrester are based on the decomposition of the measured leakage current into their capacitive and resistive components. The arrester's resistive component of the leakage current, in particular, the third harmonic component, is known as to be directly related to the degree of degradation of the ZnO blocks. This paper proposes an online monitoring technique for the surge arrester under dry and pollution conditions when measuring either the total leakage current or both the internal and external leakage currents of three different types of surge arresters. This technique based on feature extraction of the magnitudes, frequencies, and phase angles of all frequency components of the real measured current signals using Prony analysis-Hilbert transform approach and MATLAB program. The observed results illustrate the viability of this technique for online monitoring of surge arrester. Furthermore, the effect of voltage harmonics on the measured leakage currents is investigated through surge arrester model simulation performed with PSCAD program.

10 October 2011 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
MEMohamed Eladawy
Mohamed Eladawy
TPThierry Paillat
Thierry Paillat
GTGerard Touchard
Gerard Touchard
JCJuan Martin Cabaleiro
Juan Martin Cabaleiro
At the solid-liquid interface, a charge zone called the Electrical Double Layer (EDL) appears. It is constituted of two zones of opposite sign, one in the solid and another one in the liquid. When a liquid flows through a pipe, there is a disturbance of the EDL and an axial streaming current is generated. This current is due to the convection of the charges coming from the electrical double layer. In this paper, we present a numerical simulation of the EDL development process in the case of a liquid containing additives or impurities which are partially dissociated into positive and negative ones. We treat the case of laminar flow and an interfacial reaction whose conversion is small compared to the concentration of positive and negative ions in the bulk solution. The boundary conditions are deduced from the kinetics of the wall surface reactions with additives. However, in this paper, the formation of the EDL at the solid-liquid interface is investigated without any flow (static case). Thus, the rate of the wall reaction and the resulting charge concentration in the liquid can be studied. Then, once the equilibrium of physicochemical reaction is reached, convection is forced and the EDL dynamic behavior has been studied (dynamic case). The physicochemical reaction at the solid-liquid interface, the evolution of the space charge density in terms of both the axial coordinates and flow velocity, and the equations of conservation of charge of the liquid species have been implemented to a developed version of "Electricite de France" finite volume CFD tool Code_Saturne, which is designed to solve the Navier- Stokes equations. Finally, the simulation results of the dynamic behavior at different flow rates are compared with the experimental results.

10 May 2010 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
MEMohamed Eladawy
Mohamed Eladawy
TPThierry Paillat
Thierry Paillat
YBYves Bertrand
Yves Bertrand
OMOlivier Moreau
Olivier Moreau
GTGérard Touchard
Gérard Touchard
At the solid-liquid interface, a charge zone called the electrical double layer (EDL) appears. It is constituted of two zones of opposite sign: one in the solid and another one in the liquid. When a liquid flows through a pipe, an axial streaming current is generated. This current is due to the convection of the charges coming from the EDL. The physicochemical reaction at the solid-liquid interface is one of the most important parameters which control the diffuse layer development inside the liquid and, consequently, the space charge density. In this paper, we present an analysis for the physicochemical reaction in the case of liquid containing additives or impurities partially dissociated into positive and negative ions. The addition of impurities, in our case, is associated with changing both the polarity and the value of the streaming current. Thus, from this difference in streaming current, we will be able to identify the reagent of the oil with the solid material. Furthermore, the effect of streaming potential on the EDL has been undertaken. Moreover, the fully developed space charge density at the wall is calculated with the help of streaming electrification experiments which are conducted in the case of nonfully developed EDL. This procedure can be conducted for the investigation of flow electrification in transformers with oil/metal configurations.

7 May 2018 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
MEMohamed Eladawy
Mohamed Eladawy
IMIbrahim A. Metwally
Ibrahim A. Metwally
In this paper, a novel five-leg design of non-superconducting, three-phase, presaturated core fault-current limiter (PCFCL) is proposed based on the time-domain, electromagnetic finite-element simulations to overcome the main drawbacks of the well-known topologies of PCFCLs. These drawbacks are large volume of magnetic iron core, high total power loss under steady-state condition, high-induced voltage across the dc coil terminals during the fault condition, and the technical risks of high-temperature superconducting coil and cryogenics in the case of superconducting fault-current limiter (SFCLs). The general performance of PCFCL can be expressed through the steady-state power loss and voltage drop, and fault-current clipping ratio and the induced voltage across the dc coil terminals during the fault condition. Different topologies of three-phase PCFCLs are considered with the comparison of their limiting capability for different types of faults. The results reveal that the proposed design of PCFCL has superior properties in limiting any type of fault currents with reduced volume of the magnetic iron core, total power loss, and the induced voltage across the dc coil terminals in comparison with those of the well-known dual-core PCFCL design. Furthermore, a performance analysis of the novel five-leg design is considered throughout an extensive simulation of the constructive controlling parameters to study their relative effects on the general performance of operation.

1 May 2009 in Journal of Electrostatics
Verified
Journal Article
Closed access
MEMohamed Eladawy
Mohamed Eladawy
JCJ.M. Cabaleiro
J.M. Cabaleiro
TPT. Paillat
T. Paillat
OMO. Moreau
O. Moreau
GTG. Touchard
G. Touchard

23 July 2019 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
MEMohamed Eladawy
Mohamed Eladawy
IMIbrahim A. Metwally
Ibrahim A. Metwally
In this paper, the dc biasing magnetomotive force (mmf) in presaturated core fault current limiter (PCFCL) is replaced with permanent magnet (PM) to overcome the well-known drawbacks of the dc biased PCFCLs. These drawbacks are excessively induced voltage across the terminals of the dc coil during fault condition and high total power losses during the steady-state condition. The novel contributions of this paper are the introduction of the selection criteria of PM material and its representation by actual nonlinear B-H hysteresis loop of Jiles-Atherton method, and the use of PM alone as an equivalent to the dc biasing coils for three-phase fault current limiter (FCL), contrary to work reported in earlier papers. Single- and three-phase PCFCLs are modified by replacement of dc saturation coil by the equivalent PM through time-domain finite element (FE) simulation of COMSOL Multiphysics package. Experimental verification shows that the implementation of accurate nonlinear representation of PM demagnetization curve with FE simulation gives a realistic performance of the PM biased PCFCL, especially in the fault condition. The performance of PCFCL can be evaluated through the voltage drop and total power losses during the steady-state condition and the fault current clipping ratio during fault condition of the grid. Furthermore, a comparative investigation of dynamic behavior is considered between dc and PM biased PCFCLs. It is found that the PM biased PCFCL has enriched capability of limiting any type of fault current with leading advantages of reduced voltage drop and power losses significantly together with risk elimination of the high induced voltage across dc coil terminals. Moreover, the governing parameters of PM biased PCFCLs are subjected to performance analysis to study their inherent effects.