Faranak Fotouhi-Ghazvini

Dr. Faranak Fotouhi-Ghazvini

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
SASaedeh Abbaspour
Saedeh Abbaspour
Faranak Fotouhi-GhazviniFaranak Fotouhi-Ghazvini
Faranak Fotouhi-Ghazvini
ASAli Sedaghatbaf
Ali Sedaghatbaf
Hossein FotouhiHossein Fotouhi
Hossein Fotouhi
MVMaryam Vahabi
Maryam Vahabi
Maria LindénMaria Lindén
Maria Lindén
Recent advances in artificial intelligence and machine learning (ML) led to effective methods and tools for analyzing the human behavior. Human Activity Recognition (HAR) is one of the fields that has seen an explosive research interest among the ML community due to its wide range of applications. HAR is one of the most helpful technology tools to support the elderly’s daily life and to help people suffering from cognitive disorders, Parkinson’s disease, dementia, etc. It is also very useful in areas such as transportation, robotics and sports. Deep learning (DL) is a branch of ML based on complex Artificial Neural Networks (ANNs) that has demonstrated a high level of accuracy and performance in HAR. Convolutional Neural Networks (CNNs) and Recurrent Neural Networks (RNNs) are two types of DL models widely used in the recent years to address the HAR problem. The purpose of this paper is to investigate the effectiveness of their integration in recognizing daily activities, e.g., walking. We analyze four hybrid models that integrate CNNs with four powerful RNNs, i.e., LSTMs, BiLSTMs, GRUs and BiGRUs. The outcomes of our experiments on the PAMAP2 dataset indicate that our proposed hybrid models achieve an outstanding level of performance with respect to several indicative measures, e.g., F-score, accuracy, sensitivity, and specificity.

1 January 2018 in Journal of Medical Signals & Sensors
Verified
Journal Article
Open access
PDF file
Faranak Fotouhi-GhazviniFaranak Fotouhi-Ghazvini
Faranak Fotouhi-Ghazvini
BJBahareh Javid
Bahareh Javid
FZFahime Sadat Zakeri
Fahime Sadat Zakeri
Background: People with diabetes need to monitor their blood sugar levels constantly and attend health centers regularly for checkups. The aim of this study is to provide a healthcare system for mobile blood glucose and bilirubin monitoring. Methods: It includes a sensor for noninvasive blood glucose and bilirubin measurement using near-infrared spectroscopy and optical method, respectively, communicating with a smartphone. Results: It was observed that by increasing the glucose concentration, the output voltage of the sensor increases in transmittance mode and decreases in reflectance mode. Moreover, it was observed that by increasing the bilirubin concentration, the output voltage of sensor decreases in transmittance mode and increases in reflectance mode. In the collected data there was good correlations between voltage and concentration and their relationship were approximately linear. Therefore, it is possible to use noninvasive methods to predict the glucose or bilirubin concentration. In vivo experiments for glucose were carried out with 19 persons in training phase, and fve persons were used for testing the model. The glucose behavior model was built into the mobile application. The average glucose concentrations from the transmittance and reflectance mode were obtained. The average percentage error was 8.27 and root mean square error was 18.52 mg/dL. Conclusions: From this research, it can be inferred that the noninvasive optical methods implemented on wireless sensors and smartphones could form a system that can be used at any time and any place in the future as an alternative to traditional invasive blood glucose and bilirubin measurement methods.

9 January 2019 in IEEE Access
Verified
Journal Article
Open access
MSMasoumeh Sharafi
Masoumeh Sharafi
Faranak Fotouhi-GhazviniFaranak Fotouhi-Ghazvini
Faranak Fotouhi-Ghazvini
Mohsen ShiraliMohsen Shirali
Mohsen Shirali
MGMona Ghassemian
Mona Ghassemian

Verified
Journal Article
Open access
PDF file
FKFariba Khosroabadi
Fariba Khosroabadi
Faranak Fotouhi-GhazviniFaranak Fotouhi-Ghazvini
Faranak Fotouhi-Ghazvini
Hossein FotouhiHossein Fotouhi
Hossein Fotouhi
Internet of Things (IoT) networks dependent on cloud services usually fail in supporting real-time applications as there is no response time guarantees. The fog computing paradigm has been used to alleviate this problem by executing tasks at the edge of the network, where it is possible to provide time bounds. One of the challenging topics in a fog-assisted architecture is to task placement on edge devices in order to obtain a good performance. The process of task mapping into computational devices is known as Service Placement Problem (SPP). In this paper, we present a heuristic algorithm to solve SPP, dubbed as clustering of fog devices and requirement-sensitive service first (SCATTER). We provide simulations using iFogSim toolkit and experimental evaluations using real hardware to verify the feasibility of the SCATTER algorithm by considering a smart home application. We compared the SCATTER with two existing works: edge-ward and cloud-only approaches, in terms of Quality of Service (QoS) metrics. Our experimental results have demonstrated that SCATTER approach has better performance compared with the edge-ward and cloud-only, 42.1% and 60.2% less application response times, 22% and 27.8% less network usage, 45% and 65.7% less average application loop delays, and 2.33% and 3.2% less energy consumption.

1 January 2020 in Journal of Medical Signals & Sensors
Verified
Journal Article
Open access
PDF file
Faranak Fotouhi-GhazviniFaranak Fotouhi-Ghazvini
Faranak Fotouhi-Ghazvini
SASaedeh Abbaspour
Saedeh Abbaspour
Background: The tracking devices could help measuring the heart rate and energy expenditure and recognizing the user's activity. The calorie measurement is a significant achievement for the fitness tracking and the continuous health monitoring. Methods: In this paper, a combination of an accelerometer and a photoplethysmography (PPG) sensor is implemented to calculate the calories consumed. These sensors were mounted next to each other and then were placed on the ankle and finger by flat cable. The sensed data are transferred via Bluetooth to a smartphone in a serial and real-time manner. An Android App is designed to display the user's health data. The average amount of consumed energy is obtained from the combination of the accelerometer sensor based on the laws of motion and the PPG sensor based on the heart rate data. Results: The designed system is tested on 10 nonathlete males and 10 nonathlete females randomly. By applying thevelet, the value of the acceleration signal variance was reduced from 3.2 to 0.8. The correlation between PPG and pulse oximeter was 0.9. Moreover, the correlation of the accelerometer and treadmill was 0.9. The root mean square error (RMSE) and the P value of the calorie output from PPG and pulse oximeter are 0.53 and 0.008, respectively. The RMSE and the P value of the calories output from the accelerometer and the treadmill are 0.42 and 0.007, respectively. Conclusion: Our device validity and reliability were good by comparing it with a typical smart band, smart watch, and smartphone available in the market. The combined PPG and the accelerometer sensors were compared with the gold standard, the pulse oximeter, and the treadmill. According to the results, there is no significant difference in the values obtained. Therefore, a mobile system is augmented with the wireless accelerometer and PPG that are connected to a smartphone. The system could be carried out with the user at any time and any place.

1 January 2017 in Journal of Medical Signals & Sensors
Verified
Journal Article
Open access
PDF file
Faranak Fotouhi-GhazviniFaranak Fotouhi-Ghazvini
Faranak Fotouhi-Ghazvini
MGMina Golzar
Mina Golzar
HRHossein Rabbani
Hossein Rabbani
FZFahimeh Sadat Zakeri
Fahimeh Sadat Zakeri
Background: The increasing trend of heart disease has turned the attention of researchers toward the use of portable connected technologies. The necessity of continuous special care for cardiovascular patients is an inevitable fact. Methods: In this research, a new wireless electrocardiographic (ECG) signal-monitoring system based on smartphone is presented. This system has two main sections. The first section consists of a sensor which receives ECG signals via an amplifier, then filters and digitizes the signal, and prepares it to be transmitted. The signals are stored, processed, and then displayed in a mobile application. The application alarms in dangerous situations and sends the location of the cardiac patient to family or health-care staff. Results: The results obtained from the analysis of the electrocardiogram signals on 20 different people have been compared with the traditional ECG in hospital by a cardiologist. The signal is instantly transmitted by 200 sample per second to mobile phone. The raw data are processed, the anomaly is detected, and the signal is drawn on the interface in about 70 s. Therefore, the delay is not noticeable by the patient. With respect to rate of data transmission to hospital, different internet connections such as 2G, 3G, 4G, WiFi, WiMax, or Long-Term Evolution (LTE) could be used. Data transmission ranges from 9.6 kbps to 20 Mbps. Therefore, the physician could receive data with no delay. Conclusions: A performance accuracy of 91.62% is obtained from the wireless ECG system. It conforms to the hospital’s diagnostic standard system while providing a portable monitoring anywhere at anytime.