Maria Lindén

Prof. Maria Lindén

Malardalen University, School of Innovation, Design and Engineering, Embedded Sensor Systems for Health, Högskoleplan 1, 721 23 Västerås, Sweden
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RKRanpreet kaur
Ranpreet kaur
Hamid GholamHosseiniHamid GholamHosseini
Hamid GholamHosseini
RSRoopak Sinha
Roopak Sinha
Maria LindénMaria Lindén
Maria Lindén
Automatic melanoma detection from dermoscopic skin samples is a very challenging task. However, using a deep learning approach as a machine vision tool can overcome some challenges. This research proposes an automated melanoma classifier based on a deep convolutional neural network (DCNN) to accurately classify malignant vs. benign melanoma. The structure of the DCNN is carefully designed by organizing many layers that are responsible for extracting low to high-level features of the skin images in a unique fashion. Other vital criteria in the design of DCNN are the selection of multiple filters and their sizes, employing proper deep learning layers, choosing the depth of the network, and optimizing hyperparameters. The primary objective is to propose a lightweight and less complex DCNN than other state-of-the-art methods to classify melanoma skin cancer with high efficiency. For this study, dermoscopic images containing different cancer samples were obtained from the International Skin Imaging Collaboration datastores (ISIC 2016, ISIC2017, and ISIC 2020). We evaluated the model based on accuracy, precision, recall, specificity, and F1-score. The proposed DCNN classifier achieved accuracies of 81.41%, 88.23%, and 90.42% on the ISIC 2016, 2017, and 2020 datasets, respectively, demonstrating high performance compared with the other state-of-the-art networks. Therefore, this proposed approach could provide a less complex and advanced framework for automating the melanoma diagnostic process and expediting the identification process to save a life.

12 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Annica KristofferssonAnnica Kristoffersson
Annica Kristoffersson
Maria LindénMaria Lindén
Maria Lindén
This article reviews the use of wearable sensors for the monitoring of physical activity (PA) for different purposes, including assessment of gait and balance, prevention and/or detection of falls, recognition of various PAs, conduction and assessment of rehabilitation exercises and monitoring of neurological disease progression. The article provides in-depth information on the retrieved articles and discusses study shortcomings related to demographic factors, i.e., age, gender, healthy participants vs patients, and study conditions. It is well known that motion patterns change with age and the onset of illnesses, and that the risk of falling increases with age. Yet, studies including older persons are rare. Gender distribution was not even provided in several studies, and others included only, or a majority of, men. Another shortcoming is that none of the studies were conducted in real-life conditions. Hence, there is still important work to be done in order to increase the usefulness of wearable sensors in these areas. The article highlights flaws in how studies based on previously collected datasets report on study samples and the data collected, which makes the validity and generalizability of those studies low. Exceptions exist, such as the promising recently reported open dataset FallAllD, wherein a longitudinal study with older adults is ongoing.

21 November 2019 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
SASara Abbaspour
Sara Abbaspour
Maria LindénMaria Lindén
Maria Lindén
Hamid GholamHosseiniHamid GholamHosseini
Hamid GholamHosseini
ANAutumn Naber
Autumn Naber
MOMax Ortiz-Catalan
Max Ortiz-Catalan
Myoelectric pattern recognition (MPR) to decode limb movements is an important advancement regarding the control of powered prostheses. However, this technology is not yet in wide clinical use. Improvements in MPR could potentially increase the functionality of powered prostheses. To this purpose, offline accuracy and processing time were measured over 44 features using six classifiers with the aim of determining new configurations of features and classifiers to improve the accuracy and response time of prosthetics control. An efficient feature set (FS: waveform length, correlation coefficient, Hjorth Parameters) was found to improve the motion recognition accuracy. Using the proposed FS significantly increased the performance of linear discriminant analysis, K-nearest neighbor, maximum likelihood estimation (MLE), and support vector machine by 5.5%, 5.7%, 6.3%, and 6.2%, respectively, when compared with the Hudgins’ set. Using the FS with MLE provided the largest improvement in offline accuracy over the Hudgins feature set, with minimal effect on the processing time. Among the 44 features tested, logarithmic root mean square and normalized logarithmic energy yielded the highest recognition rates (above 95%). We anticipate that this work will contribute to the development of more accurate surface EMG-based motor decoding systems for the control prosthetic hands.

7 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
SASaedeh Abbaspour
Saedeh Abbaspour
Faranak Fotouhi-GhazviniFaranak Fotouhi-Ghazvini
Faranak Fotouhi-Ghazvini
ASAli Sedaghatbaf
Ali Sedaghatbaf
Hossein FotouhiHossein Fotouhi
Hossein Fotouhi
MVMaryam Vahabi
Maryam Vahabi
Maria LindénMaria Lindén
Maria Lindén
Recent advances in artificial intelligence and machine learning (ML) led to effective methods and tools for analyzing the human behavior. Human Activity Recognition (HAR) is one of the fields that has seen an explosive research interest among the ML community due to its wide range of applications. HAR is one of the most helpful technology tools to support the elderly’s daily life and to help people suffering from cognitive disorders, Parkinson’s disease, dementia, etc. It is also very useful in areas such as transportation, robotics and sports. Deep learning (DL) is a branch of ML based on complex Artificial Neural Networks (ANNs) that has demonstrated a high level of accuracy and performance in HAR. Convolutional Neural Networks (CNNs) and Recurrent Neural Networks (RNNs) are two types of DL models widely used in the recent years to address the HAR problem. The purpose of this paper is to investigate the effectiveness of their integration in recognizing daily activities, e.g., walking. We analyze four hybrid models that integrate CNNs with four powerful RNNs, i.e., LSTMs, BiLSTMs, GRUs and BiGRUs. The outcomes of our experiments on the PAMAP2 dataset indicate that our proposed hybrid models achieve an outstanding level of performance with respect to several indicative measures, e.g., F-score, accuracy, sensitivity, and specificity.

29 May 2022 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
RKRanpreet kaur
Ranpreet kaur
Hamid GholamHosseiniHamid GholamHosseini
Hamid GholamHosseini
RSRoopak Sinha
Roopak Sinha
Maria LindénMaria Lindén
Maria Lindén
Background: Melanoma is the most dangerous and aggressive form among skin cancers, exhibiting a high mortality rate worldwide. Biopsy and histopathological analysis are standard procedures for skin cancer detection and prevention in clinical settings. A significant step in the diagnosis process is the deep understanding of the patterns, size, color, and structure of lesions based on images obtained through dermatoscopes for the infected area. However, the manual segmentation of the lesion region is time-consuming because the lesion evolves and changes its shape over time, making its prediction challenging. Moreover, it is challenging to predict melanoma at the initial stage as it closely resembles other skin cancer types that are not malignant as melanoma; thus, automatic segmentation techniques are required to design a computer-aided system for accurate and timely detection. Methods: As deep learning approaches have gained significant attention in recent years due to their remarkable performance, therefore, in this work, we proposed a novel design of a convolutional neural network (CNN) framework based on atrous convolutions for automatic lesion segmentation. This architecture is built based on the concept of atrous/dilated convolutions which are effective for semantic segmentation. A deep neural network is designed from scratch employing several building blocks consisting of convolutional, batch normalization, leakyReLU layer, and fine-tuned hyperparameters contributing altogether towards higher performance. Conclusion: The network was tested on three benchmark datasets provided by International Skin Imaging Collaboration (ISIC), i.e., ISIC 2016, ISIC 2017, and ISIC 2018. The experimental results showed that the proposed network achieved an average Jaccard index of 90.4% on ISIC 2016, 81.8% on ISIC 2017, and 89.1% on ISIC 2018 datasets, respectively which is recorded as higher than the top three winners of the ISIC challenge and other state-of-the-art methods. Also, the model successfully extracts lesions from the whole image in one pass in less time, requiring no pre-processing step. The conclusions yielded that network is accurate in performing lesion segmentation on adopted datasets.

9 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Annica KristofferssonAnnica Kristoffersson
Annica Kristoffersson
Maria LindénMaria Lindén
Maria Lindén
The use of wearable body sensors for health monitoring is a quickly growing field with the potential of offering a reliable means for clinical and remote health management. This includes both real-time monitoring and health trend monitoring with the aim to detect/predict health deterioration and also to act as a prevention tool. The aim of this systematic review was to provide a qualitative synthesis of studies using wearable body sensors for health monitoring. The synthesis and analysis have pointed out a number of shortcomings in prior research. Major shortcomings are demonstrated by the majority of the studies adopting an observational research design, too small sample sizes, poorly presented, and/or non-representative participant demographics (i.e., age, gender, patient/healthy). These aspects need to be considered in future research work.