Electronic cigarettes are a recent development in tobacco harm reduction. They are marketed as less harmful alternatives to smoking. Awareness and use of these devices has grown exponentially in recent years, with millions of people currently using them. This systematic review appraises existing laboratory and clinical research on the potential risks from electronic cigarette use, compared with the well-established devastating effects of smoking tobacco cigarettes. Currently available evidence indicates that electronic cigarettes are by far a less harmful alternative to smoking and significant health benefits are expected in smokers who switch from tobacco to electronic cigarettes. Research will help make electronic cigarettes more effective as smoking substitutes and will better define and further reduce residual risks from use to as low as possible, by establishing appropriate quality control and standards.
A wide range of electronic cigarette (EC) devices, from small cigarette-like (first-generation) to new-generation high-capacity batteries with electronic circuits that provide high energy to a refillable atomizer, are available for smokers to substitute smoking. Nicotine delivery to the bloodstream is important in determining the addictiveness of ECs, but also their efficacy as smoking substitutes. In this study, plasma nicotine levels were measured in experienced users using a first- vs. new-generation EC device for 1 hour with an 18 mg/ml nicotine-containing liquid. Plasma nicotine levels were higher by 35–72% when using the new- compared to the first-generation device. Compared to smoking one tobacco cigarette, the EC devices and liquid used in this study delivered one-third to one-fourth the amount of nicotine after 5 minutes of use. New-generation EC devices were more efficient in nicotine delivery, but still delivered nicotine much slower compared to tobacco cigarettes. The use of 18 mg/ml nicotine-concentration liquid probably compromises ECs' effectiveness as smoking substitutes; this study supports the need for higher levels of nicotine-containing liquids (approximately 50 mg/ml) in order to deliver nicotine more effectively and approach the nicotine-delivery profile of tobacco cigarettes.
Background: Electronic cigarette (EC) use has grown exponentially over the past few years. The purpose of this survey was to assess the characteristics and experiences of a large sample of EC users and examine the differences between those who partially and completely substituted smoking with EC use. Methods: A questionnaire was prepared, translated into 10 different languages and uploaded in an online survey tool. EC users were asked to participate irrespective of their current smoking status. Participants were divided according to their smoking status at the time of participation in two subgroups: former smokers and current smokers. Results: In total, 19,414 participants were included in the analysis, with 88 of them (0.5%) reported not being smokers at the time of EC use initiation. Complete substitution of smoking was reported by 81.0% of participants (former smokers) while current smokers had reduced smoking consumption from 20 to 4 cigarettes per day. They were using ECs for a median of 10 months. They initiated EC use with a median of 18 mg/mL nicotine-concentration liquids; 21.5% used higher than 20 mg/mL. Only 3.5% of participants were using 0-nicotine liquids at the time of the survey. Former smokers were highly dependent (Fagerström Test for Cigarette Dependence = 7) and were heavier smokers (21 cigarettes per day when smoking) compared to current smokers. The most important reasons for initiating EC use for both subgroups was to reduce the harm associated with smoking and to reduce exposure of family members to second-hand smoking. Most considered ECs as less harmful than tobacco cigarettes, while 11.0% considered them absolutely harmless. Side effects were reported by more than half of the participants (59.8%), with the most common being sore/dry mouth and throat; side effects were mild and in most cases were subsequently resolved (partially or completely). Participants experienced significant benefits in physical status and improvements in pre-existing disease conditions (including respiratory disease such as asthma and chronic obstructive lung disease). Being former smoker was independently associated with positive effects in health and improvements in disease conditions. Conclusions: The results of this worldwide survey of dedicated users indicate that ECs are mostly used to avoid the harm associated with smoking. They can be effective even in highly-dependent smokers and are used as long-term substitutes for smoking. High levels of nicotine are used at initiation; subsequently, users try to reduce nicotine consumption, with only a small minority using non-nicotine liquids. Side effects are minor and health benefits are substantial, especially for those who completely substitute smoking with EC use. Further population and interventional studies are warranted.
The purpose of this study was to evaluate sweet-flavored electronic cigarette (EC) liquids for the presence of diacetyl (DA) and acetyl propionyl (AP), which are chemicals approved for food use but are associated with respiratory disease when inhaled. In total, 159 samples were purchased from 36 manufacturers and retailers in 7 countries. Additionally, 3 liquids were prepared by dissolving a concentrated flavor sample of known DA and AP levels at 5%, 10%, and 20% concentration in a mixture of propylene glycol and glycerol. Aerosol produced by an EC was analyzed to determine the concentration of DA and AP. DA and AP were found in 74.2% of the samples, with more samples containing DA. Similar concentrations were found in liquid and aerosol for both chemicals. The median daily exposure levels were 56 μg/day (IQR: 26-278 μg/day) for DA and 91 μg/day (IQR: 20-432 μg/day) for AP. They were slightly lower than the strict NIOSH-defined safety limits for occupational exposure and 100 and 10 times lower compared with smoking respectively; however, 47.3% of DA and 41.5% of AP-containing samples exposed consumers to levels higher than the safety limits. DA and AP were found in a large proportion of sweet-flavored EC liquids, with many of them exposing users to higher than safety levels. Their presence in EC liquids represents an avoidable risk. Proper measures should be taken by EC liquid manufacturers and flavoring suppliers to eliminate these hazards from the products without necessarily limiting the availability of sweet flavors.
Background: Although millions of people are using electronic cigarettes (ECs) and research on this topic has intensified in recent years, the pattern of EC use has not been systematically studied. Additionally, no comparative measure of exposure and nicotine delivery between EC and tobacco cigarette or nicotine replacement therapy (NRTs) has been established. This is important, especially in the context of the proposal for a new Tobacco Product Directive issued by the European Commission. Methods:A second generation EC device, consisting of a higher capacity battery and tank atomiser design compared to smaller cigarette-like batteries and cartomizers, and a 9 mg/mL nicotine-concentration liquid were used in this study. Eighty subjects were recruited; 45 experienced EC users and 35 smokers. EC users were video-recorded when using the device (ECIG group), while smokers were recorded when smoking (SM-S group) and when using the EC (SM-E group) in a randomized cross-over design. Puff, inhalation and exhalation duration were measured. Additionally, the amount of EC liquid consumed by experienced EC users was measured at 5 min (similar to the time needed to smoke one tobacco cigarette) and at 20 min (similar to the time needed for a nicotine inhaler to deliver 4 mg nicotine). Results: Puff duration was significantly higher in ECIG (4.2 ± 0.7 s) compared to SM-S (2.1 ± 0.4 s) and SM-E (2.3 ± 0.5 s), while inhalation time was lower (1.3 ± 0.4, 2.1 ± 0.4 and 2.1 ± 0.4 respectively). No difference was observed in exhalation duration. EC users took 13 puffs and consumed 62 ± 16 mg liquid in 5 min; they took 43 puffs and consumed 219 ± 56 mg liquid in 20 min. Nicotine delivery was estimated at 0.46 ± 0.12 mg after 5 min and 1.63 ± 0.41 mg after 20 min of use. Therefore, 20.8 mg/mL and 23.8 mg/mL nicotine-containing liquids would deliver 1 mg of nicotine in 5 min and 4 mg nicotine in 20 min, respectively. Since the ISO method significantly underestimates nicotine delivery by tobacco cigarettes, it seems that liquids with even higher than 24 mg/mL nicotine concentration would be comparable to one tobacco cigarette. Conclusions: EC use topography is significantly different compared to smoking. Four-second puffs with 20–30 s interpuff interval should be used when assessing EC effects in laboratory experiments, provided that the equipment used does not get overheated. Based on the characteristics of the device used in this study, a 20 mg/mL nicotine concentration liquid would be needed in order to deliver nicotine at amounts similar to the maximum allowable content of one tobacco cigarette (as measured by the ISO 3308 method). The results of this study do not support the statement of the European Commission Tobacco Product Directive that liquids with nicotine concentration of 4 mg/mL are comparable to NRTs in the amount of nicotine delivered to the user.