SRINIVASAN G

Dr. SRINIVASAN G

ELECTRICAL & ELECTRONICS ENGINEERING, MVJ College of Engineering, Bengaluru, India
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2023 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
SRINIVASAN GSRINIVASAN G
SRINIVASAN G
VRV. Mahesh Kumar Reddy
V. Mahesh Kumar Reddy
PVP. Venkatesh
P. Venkatesh
EPE. Parimalasundar
E. Parimalasundar
Introduction. The need for electrical energy has been increased sharply due to hasty growth in industrials, social and economic improvements. From the previous studies, it has been agreed that almost 13 % of the total power generated is wasted as heat loss at distribution level. It has been extensively recognized that the node voltage profile along the distribution system can be enhanced under steady state power transfer controlled by proper reactive power compensation. Capacitors have been acknowledged as reactive power compensating device in distribution systems to achieve technical and economical benefits. Novelty of this work is the application of Archimedes optimization algorithm for reactive power optimization in distribution systems so as to obtain an improved solution and also a real 94-bus Portuguese network and modified 12-bus network has been taken and validated for three different load levels which are totally new. Purpose of the proposed work is to maximize the economic benefit by reducing the power loss and capacitor purchase cost at three different load conditions subject to satisfaction of equality and inequality constraints. Methods. The economic benefit has been validated using Archimedes optimization algorithm for three load levels considering three distribution systems. Results. The computational outcomes indicated the competence of the proposed methodology in comparison with the previously published works in power loss minimization, bus voltage enhancement and more economical benefit and proved that the proposed methodology performs well compared to other methods in the literature.

3 April 2021 in Automatika
Verified
Journal Article
Open access
SRINIVASAN GSRINIVASAN G
SRINIVASAN G
Capacitor Allocation (CA) and Network Reconfiguration (NR) are the traditional methods extensively applied by the researchers for power loss reduction and node voltage improvement in radial Distribution Network (DN) for the past four decades. In recent years, simultaneous optimization of CA and NR is considered to maximize the power loss reduction in a proficient manner in comparison to individual optimization of CA and NR. To solve the objective functions, this work proposes an application of Autonomous Group Particle Swarm Optimization (AGPSO) by optimal allocation and sizing of capacitors with and without NR, under four different cases, subject to satisfying operating constraints. In addition, to ascertain the impact of real power injection on further power loss reduction, this work considers placement and sizing of Distributed Generation (DG) units from single to three optimal nodes in capacitive compensated optimal DN. This proposed methodology is demonstrated using standard IEEE 33 and 69 bus test system and the results obtained by each test case have been compared with other optimization techniques. A significant amount of power loss gets minimized after optimal DG allocation in reactive power compensated optimal DN.

1 January 2023 in International Journal of Applied Science and Engineering
Verified
Journal Article
Open access
PDF file
VSV. Shanmugasundaram
V. Shanmugasundaram
SRINIVASAN GSRINIVASAN G
SRINIVASAN G
MLM. Lavanya
M. Lavanya
Utilities have been forced to raise the overall efficiency towards a better position in radial distribution systems (DS). From the literature, it has been proved that reactive power compensation performs well in minimizing the PLoss and enhancing the bus voltage profile within the permissible range in radial DSs. This work presents the salp swarm algorithm (SSA) to solve the problem efficiently. The merit of this technique is that it can offer a global or near-global optimum for capacitor siting and sizing. The main intention of this study is to obtain annual financial benefits using the placement and sizing of capacitors optimally. This can however be achieved by minimizing the objective function composed of cost-based power loss and capacitor cost on radial DS considering three different load levels. The proposed technique has been tested on standard IEEE 69 and modified 12 bus systems. Computational results are compared with the results obtained by the previous published work and proved that SSA can minimize the PLoss more effectively thereby financial benefit.

25 February 2022 in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
Verified
Journal Article
Open access
PDF file
SRINIVASAN GSRINIVASAN G
SRINIVASAN G
KAK. Amaresh
K. Amaresh
KCKumar Reddy Cheepathi
Kumar Reddy Cheepathi
Feeder reconfiguration (FR), capacitor placement and sizing (CPS) are the two renowned methods widely applied by the researchers for loss minimization with node voltage enrichment in the electrical distribution network (EDN), which has an immense impact on economic savings. In recent years, optimization of FR and CPS together can proficiently yield better power loss minimization and save costs compared to the individual optimization of FR and CPS. This work proposes an application of an improved salp swarm optimization technique based on weight factor (ISSOT-WF) to solve the cost-based objective function using CPS with and without FR for five different cases and three load levels, subject to satisfying operating constraints. In addition, to ascertain the impact of real power injection on additional power loss reduction, this work considers the integration of dispersed generation units at three optimal locations in capacitive compensated optimal EDN. The effectiveness of ISSOT-WF has been demonstrated on the standard PG&E-69 bus system and the outcomes of the 69-bus test case have been validated by comparing with other competing algorithms. Using FR and CPS at three optimal nodes and due to power loss reduction, cost-saving reached up to a maximum of 71%, and a maximum APLR of 26% was achieved after the installation of DGs at three optimal locations with the significant improvement in the bus voltage profile.


12 June 2024 in Ain Shams Engineering Journal
Verified
Journal Article
Open access
VSV. Shanmugasundaram
V. Shanmugasundaram
SRINIVASAN GSRINIVASAN G
SRINIVASAN G
KKK. Krishnamoorthi
K. Krishnamoorthi
KKK. Karthik
K. Karthik