In recent decades, there has been a growing interest in the design and development of power loss reduction in electric drive systems. To realize the full potential of the Brushless DC motor (BLDCM), the design methodology of an effective intelligent controller is vital. On the other hand, the Landsman converter is used in a bridgeless configuration to enhance the power factor and minimize the power loss of the BLDCM. In addition, BLDCM utilizes the different intelligent controllers that are used to decrease power loss. The performance of the Landsman converter and CSC converter is analyzed concerning various configurations/stages, and the numerical MATLAB 2016a simulation results are discussed to arrive at the suitable intelligent controller for the BLDC motor, and comparison results are presented. The proposed converter is designed and validated using hardware implementation by minimizing power loss. Effectiveness can be tested and valued for the proposed controller for the various intelligent controllers of BLDCM.
Pulse width modulation for Selective Harmonics Elimination (SHE) is mostly employed in the reduction of lower order harmonics. The PV system in this research provides input voltage to the reduced switch 31-level inverter, which is based on the Artificial Bee Colony algorithm. With a high gain DC-DC single-ended primary-inductor converter (SEPIC), the PV panel output voltage is kept constant. The Grey wolf optimization algorithm (GWO) approach is used to get the most power out PV scheme. Multi Carrier modulation, a high-frequency modulation technology, is also used in this novel design of the inverter to reduce upper order harmonics. The suggested Artificial Bee Colony (ABC) algorithm, harmonics is compared to a SHE technique based on a genetic algorithm. The hardware findings were confirmed using DSPIC30F2010 controller simulation, and the recommended system was validated using Matlab simulation.
The main challenge in today's power system is to supply continuous, reliable power and satisfy the high demand. The incorporation of renewable energy sources into the utility grid system can be accomplished. However, the renewable sources are intermittent in nature and the loads work dynamically and cause imbalances to the system voltage within an immediate time. Intermittent renewable sources affect the voltage of the power grid system. Photovoltaic (PV) power generation with Z-source inverter (ZSI)-based dynamic voltage restorer (DVR) is used to avoid that. For step-up low DC voltage to required AC voltage for the compensation of the voltage disturbance, ZSI with the energy storage impedance network is used. DC-DC converters connect the PV cell and the battery storage to the impedance source network. This article also incorporates an upgraded second-order generalized integrator (U-SOGI) control system for the generation of reference voltage signals. The U-SOGI control reference voltage generation approach greatly improves system performance and decreases the harmonic voltage. The voltage-related problems in the system connected to the utility grid are mitigated with DVR. In different load and source conditions, the PV generation with DVR performance is verified by the digital simulation and experimental prototype.
13 September 2024 in International Journal of Information Technology