Giacomo Villa

Dr. Giacomo Villa


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Giacomo VillaGiacomo Villa
Giacomo Villa
Serena CerfoglioSerena Cerfoglio
Serena Cerfoglio
ABAlessandro Bonfiglio
Alessandro Bonfiglio
Paolo CapodaglioPaolo Capodaglio
Paolo Capodaglio
MGManuela Galli
Manuela Galli
Veronica CimolinVeronica Cimolin
Veronica Cimolin
Inertial measurement units (IMUs) have gained popularity as portable and cost-effective alternatives to optoelectronic motion capture systems for assessing joint kinematics. This study aimed to validate a commercially available multi-sensor IMU-based system against a laboratory-grade motion capture system across lower limb, trunk, and upper limb movements. Fifteen healthy participants performed a battery of single- and multi-joint tasks while motion data were simultaneously recorded by both systems. Range of motion (ROM) values were extracted from the two systems and compared. The IMU-based system demonstrated high concurrent validity, with non-significant differences in most tasks, root mean square error values generally below 7°, percentage of similarity greater than 97%, and strong correlations (r ≥ 0.77) with the reference system. Systematic biases were trivial (≤3.9°), and limits of agreement remained within clinically acceptable thresholds. The findings indicate that the tested IMU-based system provides ROM estimates statistically and clinically comparable to those obtained with optical reference systems. Given its portability, ease of use, and affordability, the IMU-based system presents a promising solution for motion analysis in both clinical and remote rehabilitation contexts, although future research should extend validation to pathological populations and longer monitoring periods.

12 May 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Giacomo VillaGiacomo Villa
Giacomo Villa
Serena CerfoglioSerena Cerfoglio
Serena Cerfoglio
ABAlessandro Bonfiglio
Alessandro Bonfiglio
Paolo CapodaglioPaolo Capodaglio
Paolo Capodaglio
MGManuela Galli
Manuela Galli
Veronica CimolinVeronica Cimolin
Veronica Cimolin
Inertial Measurement Units (IMU) have gained popularity as portable and cost-effective alternatives to optoelectronic motion capture systems for assessing joint kinematics. This study aimed to validate a commercially available multi-sensor IMU-based system against a laboratory-grade motion capture system across lower limb, trunk, and upper limb movements. Fifteen healthy participants performed a battery of single- and multi-joint tasks while motion data were simultaneously recorded by both systems. Range of motion (ROM) values were extracted from the two systems and compared. The IMU-based system demonstrated high concurrent validity, with non-significant differences in most tasks, root mean squared error values generally below 7°, percentage of similarity greater than 97%, and strong correlations (r ≥ 0.77) with the reference system. Systematic biases were trivial (≤ 3.9°), and limits of agreement remained within clinically acceptable thresholds. The findings indicate that the tested IMU-based system provides ROM estimates statistically and clinically comparable to those obtained with optical reference systems. Given its portability, ease of use, and affordability, the IMU-based system presents a promising solution for motion analysis in both clinical and remote rehabilitation contexts, although future research should extend validation to pathological populations and longer monitoring periods.