5 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Serena CerfoglioSerena Cerfoglio
Serena Cerfoglio
Paolo CapodaglioPaolo Capodaglio
Paolo Capodaglio
PRPaolo Rossi
Paolo Rossi
ICIlaria Conforti
Ilaria Conforti
VDValentina D’Angeli
Valentina D’Angeli
Veronica CimolinVeronica Cimolin
Veronica Cimolin
In recent years, the use of inertial-based systems has been applied to remote rehabilitation, opening new perspectives for outpatient assessment. In this study, we assessed the accuracy and the concurrent validity of the angular measurements provided by an inertial-based device for rehabilitation with respect to the state-of-the-art system for motion tracking. Data were simultaneously collected with the two systems across a set of exercises for trunk and lower limbs, performed by 21 healthy participants. Additionally, the sensitivity of the inertial measurement unit (IMU)-based system to its malpositioning was assessed. Root mean square error (RMSE) was used to explore the differences in the outputs of the two systems in terms of range of motion (ROM), and their agreement was assessed via Pearson’s correlation coefficient (PCC) and Lin’s concordance correlation coefficient (CCC). The results showed that the IMU-based system was able to assess upper-body and lower-limb kinematics with a mean error in general lower than 5° and that its measurements were moderately biased by its mispositioning. Although the system does not seem to be suitable for analysis requiring a high level of detail, the findings of this study support the application of the device in rehabilitation programs in unsupervised settings, providing reliable data to remotely monitor the progress of the rehabilitation pathway and change in patient’s motor function.

29 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Serena CerfoglioSerena Cerfoglio
Serena Cerfoglio
Claudia FerrarisClaudia Ferraris
Claudia Ferraris
Luca VismaraLuca Vismara
Luca Vismara
GAGianluca Amprimo
Gianluca Amprimo
LPLorenzo Priano
Lorenzo Priano
Veronica CimolinVeronica Cimolin
Veronica Cimolin
The aim of this review was to present an overview of the state of the art in the use of the Microsoft Kinect camera to assess gait in post-stroke individuals through an analysis of the available literature. In recent years, several studies have explored the potentiality, accuracy, and effectiveness of this 3D optical sensor as an easy-to-use and non-invasive clinical measurement tool for the assessment of gait parameters in several pathologies. Focusing on stroke individuals, some of the available studies aimed to directly assess and characterize their gait patterns. In contrast, other studies focused on the validation of Kinect-based measurements with respect to a gold-standard reference (i.e., optoelectronic systems). However, the nonhomogeneous characteristics of the participants, of the measures, of the methodologies, and of the purposes of the studies make it difficult to adequately compare the results. This leads to uncertainties about the strengths and weaknesses of this technology in this pathological state. The final purpose of this narrative review was to describe and summarize the main features of the available works on gait in the post-stroke population, highlighting similarities and differences in the methodological approach and primary findings, thus facilitating comparisons of the studies as much as possible.

19 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Serena CerfoglioSerena Cerfoglio
Serena Cerfoglio
MGManuela Galli
Manuela Galli
Marco TarabiniMarco Tarabini
Marco Tarabini
Filippo BertozziFilippo Bertozzi
Filippo Bertozzi
Chiarella SforzaChiarella Sforza
Chiarella Sforza
Matteo ZagoMatteo Zago
Matteo Zago
Nowadays, the use of wearable inertial-based systems together with machine learning methods opens new pathways to assess athletes’ performance. In this paper, we developed a neural network-based approach for the estimation of the Ground Reaction Forces (GRFs) and the three-dimensional knee joint moments during the first landing phase of the Vertical Drop Jump. Data were simultaneously recorded from three commercial inertial units and an optoelectronic system during the execution of 112 jumps performed by 11 healthy participants. Data were processed and sorted to obtain a time-matched dataset, and a non-linear autoregressive with external input neural network was implemented in Matlab. The network was trained through a train-test split technique, and performance was evaluated in terms of Root Mean Square Error (RMSE). The network was able to estimate the time course of GRFs and joint moments with a mean RMSE of 0.02 N/kg and 0.04 N·m/kg, respectively. Despite the comparatively restricted data set and slight boundary errors, the results supported the use of the developed method to estimate joint kinetics, opening a new perspective for the development of an in-field analysis method.

18 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Serena CerfoglioSerena Cerfoglio
Serena Cerfoglio
Nicola Francesco LopomoNicola Francesco Lopomo
Nicola Francesco Lopomo
Paolo CapodaglioPaolo Capodaglio
Paolo Capodaglio
ESEmilia Scalona
Emilia Scalona
Riccardo MonfriniRiccardo Monfrini
Riccardo Monfrini
Veronica CimolinVeronica Cimolin
Veronica Cimolin
In recent years, wearable systems based on inertial sensors opened new perspectives for functional motor assessment with respect to the gold standard motion capture systems. The aim of this study was to validate an experimental set-up based on 17 body-worn inertial sensors (Awinda, Xsens, The Netherlands), addressing specific body segments with respect to the state-of-the art system (VICON, Oxford Metrics Ltd., Oxford, UK) to assess upper limb kinematics in obese, with respect to healthy subjects. Twenty-three obese and thirty healthy weight individuals were simultaneously acquainted with the two systems across a set of three tasks for upper limbs (i.e., frontal arm rise, lateral arm rise, and reaching). Root Mean Square error (RMSE) was computed to quantify the differences between the measurements provided by the systems in terms of range of motion (ROM), whilst their agreement was assessed via Pearson’s correlation coefficient (PCC) and Bland–Altman (BA) plots. In addition, the signal waveforms were compared via one-dimensional statistical parametrical mapping (SPM) based on a paired t-test and a two-way ANOVA was applied on ROMs. The overall results partially confirmed the correlation and the agreement between the two systems, reporting only a moderate correlation for shoulder principal rotation angle in each task (r~0.40) and for elbow/flexion extension in obese subjects (r = 0.66), whilst no correlation was found for most non-principal rotation angles (r < 0.40). Across the performed tasks, an average RMSE of 34° and 26° was reported in obese and healthy controls, respectively. At the current state, the presence of bias limits the applicability of the inertial-based system in clinics; further research is intended in this context.

10 July 2024 in Life
Verified
Journal Article
Open access
PDF file
Serena CerfoglioSerena Cerfoglio
Serena Cerfoglio
FVFederica Verme
Federica Verme
Paolo CapodaglioPaolo Capodaglio
Paolo Capodaglio
PRPaolo Rossi
Paolo Rossi
VCViktoria Cvetkova
Viktoria Cvetkova
Veronica CimolinVeronica Cimolin
Veronica Cimolin
The persistence of symptoms following COVID-19 infection represents a significant challenge in healthcare management. During the outbreak, tele-rehabilitation emerged as a new tool to support healthcare structures in providing rehabilitation services. This study assessed the effectiveness and the feasibility of a 3-week home-based motor and respiratory rehabilitation program for individuals with long COVID-19 after traditional rehabilitation. Twenty-three patients completed the program and underwent functional tests at different time points (i.e., baseline, at discharge from in-hospital rehabilitation and after tele-rehabilitation). Motor function was evaluated using the instrumented Six-Minutes Walking Test (i6MWT), with monitored heart rate and oxygen saturation. Additionally, respiratory function was measured via forced vital capacity (FVC) and maximal voluntary ventilation (MVV) tests. Significant improvements (p < 0.05) in motor and respiratory function were observed throughout the intervention, including an 18.3% increase in walked distance from the baseline. The findings suggest that the proposed home-based tele-rehabilitation shows potential in enhancing motor and respiratory function in patients with long COVID. Despite limitations such as the small sample size, lack of control group and the preliminary nature of the outcomes observed, the overall findings seem to support the feasibility of the proposed tele-rehabilitation program in managing long COVID symptoms and promoting functional recovery. Nevertheless, further research is needed to validate these findings and explore tele-rehabilitation’s potential in broader and different patient populations

14 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Giacomo VillaGiacomo Villa
Giacomo Villa
Serena CerfoglioSerena Cerfoglio
Serena Cerfoglio
ABAlessandro Bonfiglio
Alessandro Bonfiglio
Paolo CapodaglioPaolo Capodaglio
Paolo Capodaglio
MGManuela Galli
Manuela Galli
Veronica CimolinVeronica Cimolin
Veronica Cimolin
Inertial measurement units (IMUs) have gained popularity as portable and cost-effective alternatives to optoelectronic motion capture systems for assessing joint kinematics. This study aimed to validate a commercially available multi-sensor IMU-based system against a laboratory-grade motion capture system across lower limb, trunk, and upper limb movements. Fifteen healthy participants performed a battery of single- and multi-joint tasks while motion data were simultaneously recorded by both systems. Range of motion (ROM) values were extracted from the two systems and compared. The IMU-based system demonstrated high concurrent validity, with non-significant differences in most tasks, root mean square error values generally below 7°, percentage of similarity greater than 97%, and strong correlations (r ≥ 0.77) with the reference system. Systematic biases were trivial (≤3.9°), and limits of agreement remained within clinically acceptable thresholds. The findings indicate that the tested IMU-based system provides ROM estimates statistically and clinically comparable to those obtained with optical reference systems. Given its portability, ease of use, and affordability, the IMU-based system presents a promising solution for motion analysis in both clinical and remote rehabilitation contexts, although future research should extend validation to pathological populations and longer monitoring periods.