Giovanni Bonanno

Dr. Giovanni Bonanno

orcid
Research Fellow (RTDA)

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Giovanni BonannoGiovanni Bonanno
Giovanni Bonanno
LCLuca Gae Corradini
Luca Gae Corradini
This paper investigates the use of digital predictive current-mode control (DPCMC) in dc-dc three-level flying capacitor (3LFC) Buck converters. In particular, stability and flying capacitor (FC) balancing properties of predictive peak, average and valley current-mode controllers are studied when operated in single-sampled and multi-sampled mode. A variant of the multisampled DPCMC obtained through a fast-update of the duty cycle command is also disclosed and analyzed. Results indicate that single-sampled DPCMC are always stable, and that fast-update approaches can strongly improve the converter dynamic response. Multi-sampled controllers are also shown to be inherently more robust than single-sampled ones against timing mismatches in the control signals, resulting in a smaller flying capacitor (FC) voltage imbalance. The analysis is validated in simulation and experimentally on a 500 kHz, 12V-to-1.5V, 500mA 3LFC Buck case study.

23 July 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
EAEslam Abdelhamid
Eslam Abdelhamid
LCLuca Corradini
Luca Corradini
Paolo MattavelliPaolo Mattavelli
Paolo Mattavelli
Giovanni BonannoGiovanni Bonanno
Giovanni Bonanno
MAMatteo Agostinelli
Matteo Agostinelli
This paper describes a sensorless stabilization technique for peak current-mode control of three-level flying capacitor (3LFC) Buck converters. The technique eliminates the well known instability associated with the flying capacitor (FC) voltage runaway, leading to a stable and balanced FC voltage. In the proposed technique, the FC voltage imbalance is detected by measuring the duty cycle mismatch DA-DB between the two groups of switches of the 3LFC topology, an information already available to the controller without any additional sensing. The resulting compensation leads to a compact solution which can be easily embedded into an analog or digital integrated controller. Two distinct approaches are developed in this work to implement the required correction on DA-DB, namely a sensorless peak offsetting modulation (PO-MOD) and a sensorless interleaving time modulation (IT-MOD). Operation, implementation challenges and performance of both are investigated. The proposed solutions are verified through computer simulations and experimentally using a 16.5-to-3.3V, 500mA, and 500 kHz 3LFC prototype.

24 October 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
EAEslam Abdelhamid
Eslam Abdelhamid
Giovanni BonannoGiovanni Bonanno
Giovanni Bonanno
LCLuca Corradini
Luca Corradini
Paolo MattavelliPaolo Mattavelli
Paolo Mattavelli
MAMatteo Agostinelli
Matteo Agostinelli
This paper investigates basic stability properties of the three-level flying-capacitor (3LFC) Buck converter when operated under current-mode control. The proposed analysis is developed for both peak-current-mode-control (P-CMC) and valley-currentmode-control (V-CMC), and addresses both the static instability of the inductor current and the flying capacitor voltage runaway phenomenon. Conditions for avoiding current subharmonic oscillations are derived first, along with the expressions of the minimal compensation ramp which guarantees current stability throughout the entire operating range. As for the stability of the flying capacitor voltage, P-CMC results to be inherently unstable unless the converter operates with a relatively large peak-to-peak inductor current ripple, a feature not yet recognized in the literature. On the other hand, V-CMC results to be inherently stable once the static instability of the current is eliminated with an external compensating ramp - a property which has been highlighted in the literature but never formally proven. The proposed analysis is verified through a simulation model and experimentally using a 3.3V, 500mA, 500 kHz prototype.

10 November 2022 in IEEE Open Journal of Power Electronics
Verified
Journal Article
Open access
RCRuzica Cvetanovic
Ruzica Cvetanovic
Giovanni BonannoGiovanni Bonanno
Giovanni Bonanno
ACAndrea Comacchio
Andrea Comacchio
HAHossein Abedini
Hossein Abedini
DBDavide Biadene
Davide Biadene
Paolo MattavelliPaolo Mattavelli
Paolo Mattavelli
Small-signal stability and dynamic interactions among power electronic converters (PECs) and electrical grids are widely analyzed using the impedance-based approach. To reduce such interactions, a desirable feature of PECs is that their admittance exhibits dissipative behavior. Due to control delays, the PEC admittance usually exhibits non-dissipative zones around and above the crossover frequency of the inner control loop, possibly reducing the stability margins of the contemporary electrical grids. This paper proposes the double-sampling asymmetric dual-edge digital pulse-width modulator (ADE-DPWM) as an effective way to improve the passivity properties of the PEC admittance. Even in the digital implementation, the ADE-DPWM features zero delay and almost unity magnitude up to half of the switching frequency. Moreover, this paper examines the influence of ADE-DPWM on the PEC admittance even at higher frequencies, where destabilization of poorly damped grid resonances may be influenced by sampling and pulse-width modulation sidebands. Due to an operating point dependent ADE-DPWM small-signal model, the high-frequency passivity properties highly depend on the steady-state operating point. The analytical predictions are shown to be in excellent agreement with the experimental admittance measurements up to twice the switching frequency for all tested steady-state operating points.

5 September 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Giovanni BonannoGiovanni Bonanno
Giovanni Bonanno
ACAndrea Comacchio
Andrea Comacchio
Paolo MattavelliPaolo Mattavelli
Paolo Mattavelli
MCMichele Corradin
Michele Corradin
Controls involving digital pulsewidth modulators (DPWMs) are usually characterized by a non-negligible phase delay due to the analog-to-digital conversion, sampling time, shape of the carrier, and algorithm computation time. Several strategies are proposed in the literature to mitigate this delay. This article features a full DPWM based on the asymmetric dual-edge carrier that successfully overcomes this drawback. Indeed, the proposed structure allows obtaining a derivative action capable of recovering the usual delay associated with the DPWM structures and providing an additional programmable high-frequency phase boost. Besides the operation's description, this article presents an accurate small-signal analysis of the proposed DPWM architecture. The dynamic model is developed using the describing function approach. The proposed architecture and the developed small-signal model are validated in simulations and by experimental tests.

1 March 2018
Verified
Conference Paper
Closed access
FBFrancesco Bez
Francesco Bez
Giovanni BonannoGiovanni Bonanno
Giovanni Bonanno
LCLuca Corradini
Luca Corradini
CGCristian Garbossa
Cristian Garbossa
In the context of reducing total CO2 emissions as well as reducing the total copper cable length and weight on cars, automotive manufacturers propose to derive all the supply voltages from a single 48 V bus through high step-down ratio dc-dc converters. The series capacitor tapped inductor (SCTI) converter is a promising topology for efficient single-stage step-down conversion from the 48 V bus. In the synchronous version of the SCTI, however, turn-off of the synchronous rectifier at positive drain-to-source current leads to a voltage spike and to a potential catastrophic failure of the converter. In this paper a simple control technique is proposed which prevents the foregoing condition to occur. The approach enables a reliable operation of the synchronous SCTI topology without disrupting its main features and advantages, and eliminating the need for additional snubbers, voltage clamps or auxiliary windings. The approach is validated via computer simulations and experimental tests on a 48 V-to-1.5 V, 4 A SCTI converter prototype.