Girish Bal

Dr. Girish Bal


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2025 in Cancers
Verified
Journal Article
Open access
PDF file
BCBin Cai
Bin Cai
TBThomas I. Banks
Thomas I. Banks
CSChenyang Shen
Chenyang Shen
RPRameshwar Prasad
Rameshwar Prasad
GBGirish Bal
Girish Bal
SBShahed N. Badiyan
Shahed N. Badiyan
Background/Objectives: This study aims to present a structured clinical workflow for offline adaptive Biology-guided Radiotherapy (BgRT) using the RefleXion X1 PET-linac system, addressing challenges introduced by inter-treatment anatomical and biological changes. Methods: We propose a decision tree offline adaptation framework based on real-time assessments of Activity Concentration (AC), Normalized Target Signal (NTS), and bounded dose-volume histogram (bDVH%) metrics. Three offline strategies were developed: (1) preemptive adaptation for minor changes, (2) partial re-simulation for moderate changes, and (3) full re-simulation for major anatomical or metabolic alterations. Two clinical cases demonstrating strategies 1 and 2 are presented. Results: The preemptive adaptation strategy was applied in a case with early tumor shrinkage, maintaining delivery parameters within acceptable limits while updating contours and dose distribution. In the partial re-Simulation case, significant changes in PET signal necessitated a same-day PET functional modeling session and plan re-optimization, effectively restoring safe deliverability. Both cases showed reduced target volumes and improved OAR sparing without additional patient visits or tracer injections. Conclusions: Offline adaptive workflows for BgRT provide practical solutions to address inter-fractional changes in tumor structure and function. These strategies can help maintain the safety and accuracy of BgRT delivery and support clinical adoption of PET-guided radiotherapy, paving the way for future online adaptive capabilities.

13 November 2025 in Cancers
Verified
Journal Article
Open access
PDF file
MAM.Ramish Ashraf
M.Ramish Ashraf
DPDaniel Pham
Daniel Pham
GBGirish Bal
Girish Bal
HCHuixiao Chen
Huixiao Chen
Henry S. ParkHenry S. Park
Henry S. Park
MSMurat Surucu
Murat Surucu
Background/Objectives: The aim of this study was to establish the relationship between target size and the required diagnostic PET maximum standard uptake value (SUVmax) thresholds needed for successful Biology-guided Radiotherapy (BgRT) delivery on RefleXion X1 PET-linac. The current clinical eligibility recommendation is an SUVmax ≥ 6 at simulation, but the RefleXion system subsequently evaluates Activity Concentration (AC), which must exceed 5 kBq/mL for successful BgRT planning. Methods: A custom 3D-printed phantom containing six spherical targets (8 to 20 mm diameter) was used with varying target-to-background ratios (5:1 to 20:1) of 18F-FDG to systematically achieve a range of SUVmax values for each target size. Images were acquired on Siemens Biograph mCT for SUVmax quantification and RefleXion X1 for AC measurements. Twenty-four BgRT plans were evaluated, and delivery accuracy was validated using ArcCHECK. Additionally, retrospective data from 18 patients across four institutions were analyzed to validate the phantom-derived findings. Results: The PET-linac successfully planned treatments for 13/24 experiments, all achieving an AC > 5 kBq/mL. SUVmax requirements varied by target size: 16–20 mm targets required an SUVmax > 6, consistent with current recommendations, while smaller targets required higher thresholds (e.g., 13 mm: SUVmax > 10, and 11 mm: SUVmax > 15). 8 and 9 mm targets failed to meet AC requirements even at SUVmax 14. Successful deliveries maintained acceptable accuracy, with gamma passing rates of 92.4% ± 5.0% (3%/2 mm) and 97.6% ± 1.9% (3%/3 mm). Analysis revealed that Volume (cc) × SUVmax > 11 consistently predicted successful BgRT planning across all target sizes. This threshold was validated using multi-institutional PET-CT patient data (mean: 11.36, 95% CI: 9.1–12.9), correctly predicting treatment eligibility in 15 of 18 cases. Conclusions: Target size significantly influences BgRT eligibility. We derived a new criterion, Volume(cc) × SUVmax > 11 (95% CI: 9.1–12).