Gitanjali Mehta

Dr. Gitanjali Mehta


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2021 in Journal of Energy Resources Technology
Verified
Journal Article
Closed access
PDF file
SAShahroz Anjum
Shahroz Anjum
VMV. Mukherjee
V. Mukherjee
GMGitanjali Mehta
Gitanjali Mehta


25 May 2021 in Journal of Solar Energy Engineering
Verified
Journal Article
Closed access
PDF file
SAShahroz Anjum
Shahroz Anjum
VMVivekananda Mukherjee
Vivekananda Mukherjee
GMGitanjali Mehta
Gitanjali Mehta
Individual performance of photovoltaic (PV) modules is contravened by mismatch losses which result in blockage in most of the solar power generated by the PV array (PVA). Partial shading conditions (PSCs) are the main causes of these losses. Several techniques have been discussed to reduce the issues caused by PSCs. Reconfiguration techniques have been proven to be one of the most successful methods that help toward this cause. In this method, the location of PV module (PVM) in the PVA is reconfigured so that the shading effects get distributed throughout the entire array and, hence, maximizing the power output. Two novel reconfiguration patterns such as canonical SuDoKu (CS) and multi diagonal SuDoKu (MDS) for total cross tied (TCT) configuration have been put forth in this paper. This approach aims to rearrange the PVMs in the TCT array as per the fed-in patterns without causing a change in the internal electrical connections. Further parts of the paper focus on the comparison of the proposed pattern's performance with other pre-existing PVA arrangements such as, TCT, SuDoKu, optimal SuDoKu (OS), and modified SuDoku (MS) by taking into account the effects of global maximum power (GMP) point, mismatch power loss, fill factor, and performance ratio. The results obtained from the detailed analysis presented in this paper give proper evidence that, in many cases, the GMP is amplified in the CS and, in all cases, GMP is amplified in the proposed MDS PVA under different shading conditions.

1 January 2013 in IETE Journal of Research
Verified
Journal Article
Closed access
GMGitanjali Mehta
Gitanjali Mehta
SSSajjanPal Singh
SajjanPal Singh

1 September 2018
Verified
Conference Paper
Closed access
GMGitanjali Mehta
Gitanjali Mehta
GMGaurav Mittra
Gaurav Mittra
VYVinod Kumar Yadav
Vinod Kumar Yadav
Data centers are playing a key role by helping enterprises to expand their capabilities in the field of information technology. As compared to manual documentations just few decades before, data centers have proved to be a boom by improving the usability of data as a holistic approach. They have enabled the enterprises to achieve much more in a minimal cost in terms of speed, time, security and physical space required for data management. Role of data centers is still critical with change in technology and rise in data demand with time resulting a dramatic shift in the way data centers are designed, configured and operated.Internet of Things (IoT) with reference to data center can be defined as something that connects "remote assets" and pushes data between them and centralized management systems. Companies can integrate that data and those assets in their processes to improve utilization and productivity. With the availability of real time information on status, location, functionality and behavior by integrating IoT with the assets and related organizational processes it becomes easy to improve the efficiency and productivity through optimum usage and more accurate decision support.Wide area network links in most of the data centers today are designed to cater moderate bandwidth requirements of human interactions with applications. However, with the evolution of IoT, big data requirements are resulting as the key demand factor for capacity management at data centers to proactively meet the business requirement associated with IoT. Tremendous increment in data and the amount of network connections that carry this traffic along with huge storage and compute requirements resulted in need of distributed data center management and optimum system management platforms.Operations and maintenance of these distributed data centers infrastructure as a homogeneous system to monitor and control segregated locations is a challenge in itself.In this study the author have tried to explain the data centers operational challenges and impact of IoT on the same.

3 December 2020 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
SAShahroz Anjum
Shahroz Anjum
VMVivekananda Mukherjee
Vivekananda Mukherjee
GMGitanjali Mehta
Gitanjali Mehta
Being the most abundant renewable source of energy, photovoltaic arrays (PVA) are extensively used for power generation. A number of factors influence performance of the PVAs, among which complete or partial shading of PVAs is perceived as a major concern for the researchers. Complete or partial shading reasonably reduces the output power of PVAs which subsequently leads to multiple maximum power points (MPPs) in the P-V curves. One of its major consequences is reverse power flow, conventionally blocking diodes (BD) based on different configuration are utilized to limit the adverse effects of reverse power flow. This paper proposes a novel scheme to improvise performance of the photovoltaic array configuration (PVAC) under-shaded condition, in which conventionally used BDs are replaced by blocking P-MOSFET (BP-MOS). A comparison study is carried out to determine performance of four different PVAC’s such as series-parallel (SP), total-cross-tied (TCT), bridge-link (BL), and honey-comb (HC) employing BDs as well as BP-MOS. Simulations are accomplished on MATLAB/SIMULINK, in order to analyze practical implications of preferred the PVAC under various illumination conditions (such as horizontal, vertical, and diagonal). Obtained results reveal efficacy of the proposed configuration in terms of least power loss, increased fill factor, and thus maximum efficiency.