Gonzalo Abad

Dr. Gonzalo Abad

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2021 in IEEE Access
Verified
Journal Article
Open access
IMIosu Marzo
Iosu Marzo
Alain Sanchez-RuizAlain Sanchez-Ruiz
Alain Sanchez-Ruiz
JBJon Andoni Barrena
Jon Andoni Barrena
GAGonzalo Abad
Gonzalo Abad
IMIgnacio Muguruza
Ignacio Muguruza
Multilevel Voltage-Source Converters (VSC) based on modular structures are envisioned as a prominent alternative for grid and industry applications. Foremost among these are the Cascaded H-Bridge (CHB) and the Modular Multilevel Converter (MMC). In this context, depending on the application and the power conversion structure, unbalanced operating conditions can be asked to the converter. Previous investigations regarding the operation and the solutions for modular structures under unbalanced conditions have already addressed this topic, but information is dispersed over a wide number of sources. This paper identifies, classifies, and analyzes the intercluster active power balancing strategies for the adequate operation of the most commonly used modular structures in some typical unbalanced operating scenarios: the Static Synchronous Compensator (STATCOM) under unbalanced voltage and/or current conditions, the unequal power generation in large-scale photovoltaic (PV) power plants, and the uneven power distribution in a battery energy storage system (BESS). Each of the applications has been independently studied so as to provide a comprehensive analysis of the alternative techniques found in the specialized literature, clearly explaining their respective strengths and drawbacks. Several future challenges have been identified during the study, which will involve greater research effort in this key research topic.

29 August 2019 in Electronics
Verified
Journal Article
Open access
PDF file
LTLukas Tapia
Lukas Tapia
IBIgor Baraia-Etxaburu
Igor Baraia-Etxaburu
JVJuan Jose Valera
Juan Jose Valera
Alain Sanchez-RuizAlain Sanchez-Ruiz
Alain Sanchez-Ruiz
GAGonzalo Abad
Gonzalo Abad
Electric propulsion and integrated hybrid power systems can improve the energy efficiency and fuel consumption of different kinds of vessels. If the vessel power system is based on DC grid distribution, some benefits such as higher generator efficiency and lower volume and cost can be achieved. However, some challenges remain in terms of protection devices for this kind of DC grid-based power system. The absence of natural zero crossing in the DC current together with the fast and programmable breaking times required make it challenging. There are several papers related to DC breaker topologies and their role in DC grids; however, it is not easy to find comprehensive information about the design process of the DC breaker itself. In this paper, the basis for the design of a DC solid-state circuit breaker (SSCB) for low voltage vessel DC grids is presented. The proposed SSCB full-scale prototype detects and opens the fault in less than 3 µs. This paper includes theoretical analyses, design guidelines, modeling and simulation, and experimental results.

20 December 2021 in IEEE Access
Verified
Journal Article
Open access
CRCarlos Ruiz
Carlos Ruiz
GAGonzalo Abad
Gonzalo Abad
MZMarkel Zubiaga
Markel Zubiaga
DMDanel Madariaga
Danel Madariaga
JAJoseba Arza
Joseba Arza
The operation of offshore wind power plants with respect to power quality and grid code compliance must be verified for different conditions in the design phase using harmonic analysis methods. This paper addresses this verification by first considering a scenario in which wind turbines operate with a typically used modulation strategy, carrier-based pulse width modulation. The studies are performed at several operating points, not only at the rated condition, and at two points of the electrical infrastructure, at the point of connection of the wind turbine and at the point of common coupling of the offshore wind farm. For this type of modulation technique and according to the resonance conditions of the studied offshore system, the harmonic distortion of current signals is relatively high and the compliance of the German – grid code is not achieved. To tackle this, wind turbine manufacturer oriented solutions are proposed with the aim of improving the harmonic emission of the offshore wind farm. The implementation of a particular solution of selective harmonic elimination is presented together with complementary solutions to further improve the harmonic emission of the wind power facility. Furthermore, this paper discloses the modeling approach to account for an adequate harmonic assessment of the wind power plant under study.

9 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
GAGonzalo Abad
Gonzalo Abad
Alain Sanchez-RuizAlain Sanchez-Ruiz
Alain Sanchez-Ruiz
JVJuan Jose Valera
Juan Jose Valera
AMAritz Milikua
Aritz Milikua
Having a method for analyzing and designing regulators of controls that contain many current loops such as active filters is not a trivial task. There can be many parameters of regulators and filters that must be carefully selected in order to fulfill certain desired requirements. For instance, these can be stability, dynamic response, robustness under uncertainty of parameters, and rejection capability to switching harmonics. Hence, this paper provides general analysis guidelines for designing current control loops by using mathematical models in an αβ reference frame. Then, by using the proposed modeling tool, a multi-objective tuning algorithm is proposed that helps obtain all the control loops’ regulator and filter parameters, meeting all the desired requirements. Thus, the proposed analysis and design methodology is illustrated by applying it to three different controls conceived in a dq rotating reference frame with PI (Proportional Integral) regulators. The first control presents two current loops (simple dq current control), the second control uses four current loops (dual vector control, for unbalanced loads), while the third control presents eight current loops (active filter controlling current harmonics). Several experimental and simulation results show the effectiveness and usefulness of the proposed method. Since the mathematical model employed is in the αβ reference frame, it can also be easily applied to controls conceived in a αβ reference frame using resonant regulators, providing also a common comparative framework.

24 January 2022 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
ABAitor Bilbao
Aitor Bilbao
GAGonzalo Abad
Gonzalo Abad
Alain Sanchez-RuizAlain Sanchez-Ruiz
Alain Sanchez-Ruiz
EUEneko Unamuno
Eneko Unamuno
MZMarkel Zubiaga
Markel Zubiaga
PIPedro Izurza-Moreno
Pedro Izurza-Moreno
The present paper focuses the analysis on a Static Synchronous Compensator (STATCOM) that operates simultaneously providing reactive power and several current harmonics of different frequencies (active power filter or active impedance functionalities). Being more specific, this paper proposes a general limitation method that reduces the current references of the STATCOM, whenever the current or voltage limit of the converter is exceeded. In a realistic operation scenario, the STATCOM’s operator may ask for certain reactive power and harmonic current reference signals and depending on the actual grid voltage conditions (unbalances and harmonics), the required converter voltage and current may exceed their limit. Consequently, the proposed limitation method protects the STATCOM system from malfunctioning when the voltage limit is exceeded and from damages when the current limit is exceeded. Hence, the paper first proposes a limitation method oriented to a STATCOM that operates solely exchanging reactive power. Secondly, the limitation method is generalized for a STATCOM that controls reactive power as well as several current harmonics. Then, simulation and experimental results are provided to validate the proposed limitation method, under a rich variety of working conditions. Finally, a conceptual analysis of the method is carried out confronting it against several possible limitation alternatives.

24 May 2018 in Energies
Verified
Journal Article
Open access
PDF file
GAGonzalo Abad
Gonzalo Abad
ALAitor Laka
Aitor Laka
GSGabriel Saavedra
Gabriel Saavedra
JBJon Andoni Barrena
Jon Andoni Barrena
This paper presents an analytical model, oriented to study harmonic mitigation aspects in AC grids. As it is well known, the presence of non-desired harmonics in AC grids can be palliated in several manners. However, in this paper, a power electronic-based active impedance at selective frequencies (ACISEF) is used, due to its already proven flexibility and adaptability to the changing characteristics of AC grids. Hence, the proposed analytical model approach is specially conceived to globally consider both the model of the AC grid itself with its electric equivalent impedances, together with the power electronic-based ACISEF, including its control loops. In addition, the proposed analytical model presents practical and useful properties, as it is simple to understand and simple to use, it has low computational cost and simple adaptability to different scenarios of AC grids, and it provides an accurate enough representation of the reality. The benefits of using the proposed analytical model are shown in this paper through some examples of its usefulness, including an analysis of stability and the identification of sources of instability for a robust design, an analysis of effectiveness in harmonic mitigation, an analysis to assist in the choice of the most suitable active impedance under a given state of the AC grid, an analysis of the interaction between different compensators, and so on. To conclude, experimental validation of a 2.15 kA ACISEF in a real 33 kV AC grid is provided, in which real users (household and industry loads) and crucial elements such as wind parks and HVDC systems are near inter-connected.