Guanghui Liang

Dr. Guanghui Liang

Tianjin University, Tianjin, China
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SRShangjie Ren
Shangjie Ren
YWYu Wang
Yu Wang
GLGuanghui Liang
Guanghui Liang
DFDong Feng
Dong Feng
As a nondestructive, nonradioactive, and high temporal resolution technique, electrical impedance tomography (EIT) has potential applications in industrial and biomedical imaging. A novel geometrically constrained boundary reconstructor (GCBR) is presented for EIT. It can directly calculate the boundary of the target inclusions embedded into a homogeneous background conductivity and is robust to noise. The proposed GCBR depends on a specially designed energy function, which consists of the residual term and the geometric constraints' term. The residual term drives the estimated inclusion boundary to the targets. The geometric constraints' term regularizes the estimations and automatically excludes the meaningless boundary guesses from the candidate solution. A set of numerical tests are conducted to discuss the key factors influencing the boundary reconstruction performance. A set of experimental tests are conducted to evaluate the performance of the proposed GCBR. The position, size, and shape of the target inclusions are well reconstructed from the real data. The mean position error and mean Hausdorff distances between the target and reconstructed boundaries are 0.39% and 2.2% of the maximal observation diameter, respectively. The mean area errors and the mean area of the symmetric difference between the target and reconstructed inclusion regions are 0.32% and 2.54% of the total observation area, respectively.

30 June 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SRShangjie Ren
Shangjie Ren
RGRu Guan
Ru Guan
GLGuanghui Liang
Guanghui Liang
DFDong Feng
Dong Feng
A deep neural network is proposed for solving the dynamic image reconstruction problems in electrical impedance tomography (EIT), which can realize the filtering, smoothing, and prediction of the dynamic conductivity reconstruction. This framework includes a reconstruction network, convolutional neural network (CNN) encoder, recurrent neural network (RNN) model, and CNN decoder, thus is termed by RCRC. The RCRC can automatically learn prior spatial–temporal information from the voltage-to-conductivity training dataset and utilize it to enhance the conductivity reconstruction accuracy. Circular acceleration and pendulum systems are simulated with a water tank model. Stochastic data interpolation and dynamic data synthesis methods were proposed to generate large-scale dynamic dataset from a small-scale static dataset. The experimental results show that RCRC can accurately recover dynamic conductivity images from EIT noisy voltage sequence. Long-term conductivity prediction was also achieved by using the proposed network.

29 January 2020 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
GLGuanghui Liang
Guanghui Liang
SRShangjie Ren
Shangjie Ren
DFDong Feng
Dong Feng
A shape-based statistical inversion method is proposed for Electrical Impedance Tomography (EIT) and Ultrasound Reflection Tomography (URT) dual-modality imaging. It is promising to improve the imaging accuracy in inclusion detection problems. The proposed image reconstruction method is based on the statistical shape inversion framework. The likelihood function is derived from EIT and URT forward models. The prior distribution is constructed using the Markov random field (MRF) prior. The measurement uncertainty is modeled by conditional error model method. The statistical shape inversion problem is solved by the Maximum a posterior (MAP) method with conventional error model. A set of numerical and experimental tests are carried out to evaluate the performance of the proposed method. The results show that the proposed EIT/URT dual-modality imaging method has obvious improvement in imaging accuracy compared to the traditional single-modality EIT and URT methods.

26 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
GLGuanghui Liang
Guanghui Liang
SRShangjie Ren
Shangjie Ren
SZShu Zhao
Shu Zhao
DFDong Feng
Dong Feng
An image reconstruction method is proposed based on Lagrange-Newton method for electrical impedance tomography (EIT) and ultrasound tomography (UT) dual-modality imaging. Since the change in conductivity distribution is usually accompanied with the change in acoustic impedance distribution, the reconstruction targets of EIT and UT are unified to the conductivity difference using the same mesh model. Some background medium distribution information obtained from ultrasound transmission and reflection measurements can be used to construct a hard constraint about the conductivity difference distribution. Then, the EIT/UT dual-modality inverse problem is constructed by an equality constraint equation, and the Lagrange multiplier method combining Newton-Raphson iteration is used to solve the EIT/UT dual-modality inverse problem. The numerical and experimental results show that the proposed dual-modality image reconstruction method has a better performance than the single-modality EIT method and is more robust to the measurement noise.

15 October 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GLGuanghui Liang
Guanghui Liang
DFDong Feng
Dong Feng
Ville KolehmainenVille Kolehmainen
Ville Kolehmainen
Marko VauhkonenMarko Vauhkonen
Marko Vauhkonen
SRShangjie Ren
Shangjie Ren
As a noninvasive and nonradiation imaging modality, ultrasonic transmission tomography (UTT) has gained much attention in process parameter detections, such as multiphase flow measurement and combustion diagnosis. However, traditional static UTT image reconstruction methods suffer from the problems of image smearing and blurring when reconstructing time-varying process parameters. To overcome this problem, a nonstationary UTT image reconstruction method is proposed based on the Bayesian inversion framework, where the nonstationary UTT inverse problem is formulated as a state estimation problem using a pair of state evolution and observation update equations. The nonstationary UTT inverse problem is solved by the Kalman filter, and a prior-based dimension reduction method is proposed to reduce the computational complexity. In addition, a dimension reduction Kalman smoother is proposed and applied for postprocessing the Kalman filter results, which can improve the imaging quality, especially for the initial states. A series of numerical and experimental tests are carried out to evaluate the performance of the proposed methods. The results show that the proposed nonstationary UTT image reconstruction methods have higher temporal resolution and better imaging quality in nonstationary process parameter estimation compared with the traditional static UTT image reconstruction methods.

28 August 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Chao TanChao Tan
Chao Tan
HJHaoran Jia
Haoran Jia
GLGuanghui Liang
Guanghui Liang
XWXuan Wang
Xuan Wang
WNWeifei Niu
Weifei Niu
DFDong Feng
Dong Feng
In recent decades, process tomography has received widespread attentions in industrial multiphase flow monitoring. Traditional single-modality tomography is usually sensitive to a specific physical parameter and is widely used in two-phase flow monitoring. However, when the fluids are more than two phases, such as oil/gas/water three-phase flow, the complexity of existence forms of three fluids brings a challenge to single-modality tomography. Multi-modality tomography can obtain more information, possessing the unique advantages in three-phase flow monitoring. In this paper, a combinable multi-modality tomography system based on industrial compact peripheral component interconnect (CPCI) bus is designed. The system includes electrical resistance tomography, electrical capacitance tomography, and ultrasonic transmission tomography, supporting independent work or free combination of different modalities for different measurement requirements. The data acquisition and transmission are controlled by the field programmable gate array (FPGA), which can synchronize the asynchronous clock signals of different boards through flexible programming. Interboard communication based on CPCI bus supports the coordination and synchronization of multi-modal boards, and also facilitates the expansion of system functions in the future. Static experimental results show that the designed multi-modal system can coordinate multi-modal data acquisition timing, and exhibit better performance in acquisition speed, signal-to-noise ratio and image reconstruction.