More and more light-emitting diode lighting devices (LED) are being connected to modern power distribution lines. In addition to its many positive features, this poses problems in terms of reactive power compensation. The large number of LEDs interacting with traditional reactive power compensators leads to a harmful phenomenon—overcompensation. This was experimentally determined in the investigated power distribution lines. Along with LEDs, a large number of devices with variable frequency drives (VFD) are connected to the same power distribution lines. This study presents an innovative approach to conventional diode rectifier supply side AC-DC-AC VFDs. It is proposed to use these VFDs as a reactive power compensation device while maintaining their main functions—motor powering and motor speed control. Minor improvements have been proposed to enable these VFDs to provide and draw out reactive power, thereby keeping power factors close to the unit in LED-loaded power distribution lines. The proposed improvements are based on the interaction between the power distribution lines inductivity and the DC circuit capacitance of the VFD. It has been shown that the power factor can be controlled by varying the capacity of the DC circuit. The ability of the AC-DC-AC VFD to compensate for the reactive power provided by the light-emitting diode lighting devices was confirmed by mathematical calculations and experimentally with a laboratory prototype.
In this paper, a novel approach to matrix-converter-based variable frequency drives is presented. It is proposed that these drives are used to provide or draw out reactive power from the power distribution line, keeping the power factor close to unit and, simultaneously, performing their primary function of motor powering and speed control. This application of matrix-converter-based variable frequency drives is required due to the need to compensate for capacitive reactive power generated by light emitting diode lighting devices. In this study, the reactive power compensation range of the matrix-converter-based variable frequency drive is determined, and a method is proposed to extend the compensation range.
In this study, an innovative approach to matrix-converter-based AC-–AC variable frequency drives (VFDs) is introduced. The possibility of using AC–AC matrix VFDs for reactive power compensation in conventional AC–DC–AC VFD-loaded power distribution lines is investigated. It is found that the interaction of a large number of conventional AC–DC–AC VFDs with a conventional capacitor-based local compensation device leads to overcompensation in 0.4 kV power distribution lines. This is due to the fact that the conventional compensation device is designed to compensate the lagging reactive power produced by inductive loads, such as AC motors. This highlights the demand for the compensation of leading reactive power that is not predicted by the designer. To solve this problem, the modification of a certain number of previously installed VFDs by replacing their conventional AC–DC–AC converters with AC–AC matrix converters is proposed. This can lead to improvements in the power factor in 0.4 kV power distribution lines. In this study, the range of reactive power produced by conventional AC–DC–AC VFDs was determined mathematically, by simulation, and experimentally. The range of reactive power produced by the novel AC–AC matrix VFD was also determined. On that basis, the number of VFDs to be modified is defined to keep the power factor close to unity.
The analysis presented in this paper is focused on the harmonics distortion damping in the case of bidirectional power-flow of the electronics device—matrix converter as an interface between two power sources. Bidirectional energy flow takes place in the matrix converter that is used in renewables, hybrid transformers, microgrids, etc. It is observed that the matrix converter generates sinusoidal voltage with some amount of harmonic distortion and worsens in the quality of power in the utility grid. Taking into account the bi-directional energy flow and the matrix converter operation principle, four key requirements for the filters are formulated. Six theoretically possible filter topologies are investigated for compliance with these requirements. Two of the filter topologies are recognized as complying with these requirements and applicable for the switching ripple harmonics damping in the utility grid connected matrix converter in the case of bidirectional power flow. The suitability of these topologies was verified by MATLAB/Simulink simulation. Using the proper filter topology will significantly reduce the size, weight and cost of the components of the filter, as well as the utility grid’s pollution by switching ripple harmonics. It is appropriate to apply such filters to matrix converters that operate in wind turbines installed in doubly fed induction generators. These filters should also be used in hybrid transformers and other high-power devices with matrix converters.
Hysteresis current controllers (HCCs) are extensively used in low-frequency power inverters and active power filters. Very little is known about their strengths and weaknesses when applied at supraharmonic frequencies. The major concern regarding the use of HCCs is their variable and uncontrollable switching frequencies. This results in difficulties in filter design, high switching losses, and the possibility of resonance conditions with power system elements. In this article, investigations are conducted on the application of HCCs in a hybrid filter for a 6 kHz matrix converter (MC)-coupled supraharmonic load. The effects of the MC-coupled load and VSC switches on the HCC’s switching frequency are analyzed. A novel mathematical model for obtaining a fixed-frequency HCC is presented. The model is verified in open- and closed-loop HCC control configurations for a three-phase hybrid active power filter (HAPF). Fast Fourier transform (FFT) analysis of the supply current after the implementation of the novel HCC-HAPF showed 2.31% of the 50 Hz fundamental. The analysis is verified in a MATLAB/Simulink environment.
Households with photovoltaic installations contribute to reducing greenhouse gas emissions and mitigating global climate change. To fully utilize the benefits of clean solar energy, it is essential to ensure its efficient use, which can be achieved by consuming all generated energy locally, within the household or a microgrid community, eliminating wastage during the grid transportation and storage. In this work, we propose a method to enhance self-consumption by eliminating simultaneous bidirectional energy flow in the phase lines of a three-phase grid-tied household system, particularly in cases of significant load asymmetry. We developed an adaptive power flow management (APFM) algorithm which distributes solar-generated energy across the household grid’s phase lines based on their respective loads and solar power generation level. A simulation based on real-world data demonstrated that the APFM algorithm both eliminates simultaneous active power import and export flows and ensures that all power exported from the household to the DSO grid remains symmetrical across all phase lines. As observed from the simulation results, applying the APFM algorithm reduced the daily imported and exported energy between the household and the DSO grid by an average of 27.5% during the spring–autumn period for a specific household. Additionally, reducing energy flow led to a 5% average increase in self-consumption within the household grid, with peak improvements reaching 16.5%.