Hafiz Muhammad Tayyab Khushi

Dr. Hafiz Muhammad Tayyab Khushi

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2023 in IEEE Access
Verified
Journal Article
Open access
Hafiz Muhammad Tayyab KhushiHafiz Muhammad Tayyab Khushi
Hafiz Muhammad Tayyab Khushi
TMtehreem masood
tehreem masood
AJArfan Jaffar
Arfan Jaffar
Muhammad RashidMuhammad Rashid
Muhammad Rashid
SASheeraz Akram
Sheeraz Akram
A brain tumor considered the deadliest disease in the world. Patients with misdiagnoses and insufficient treatment have a lower chance of surviving for life. However, for diagnosing the disturbance in the brain, magnetic resonance images play a vital role, but due to the large number of images produced by MRI, it is time-consuming and difficult to diagnose a patient at an earlier stage with high accuracy. Brain tumor detection is challenging due to variations in its size, location, and similarity in health tissues. Further, early detection of brain tumors plays a vital role in enabling a wider range of treatment options, improvements in survival rate, and patients quality of life with reduced healthcare costs. That’s why there is a need for an automatic, accurate system that can detect brain tumor at an earlier stage with an accurate result. So, in this research article, pretrained modals such as AlexNet, VGG16, VGG19, ResNet50, InceptionV3, DenseNet121, and all variants of the EfficientNet model were chosen because of their exceptional performance in tasks like feature extraction and image classification with the capability of detecting anomalies in images. The experiment was done on a publicly available multiclass dataset for brain tumor. Further, before passing the dataset to the model, preprocessing was applied to the dataset in terms of resizing the images to the same size; further images were cropped due to the extra boundaries around the images; noise was removed from the images using the FastNIMeans Denoising colored filter; and a data augmentation technique was applied to reduce the overfitting problem and ensure accurate fast training. On different pretrained deep learning models, the EfficientNetB7 model produced better results in terms of validation accuracy. Further pretrained EfficientNetB7 model were customized by adding a few layers and fine-tuning parameters. Our customized pretrained EfficientNetB7 (CPEB7) model was evaluated in terms of accuracy, loss, precision, sensitivity, specificity, recall, f1-score, and MIOU (mean intersection over union) and the model achieved accuracy of 98.57%, 98.97%, 98.97%, and 99.38% for no, meningioma, pituitary, and glioma tumor classes, respectively. Further, our proposed model achieved an overall accuracy of 98.97% with a 1.02% miss classification rate and MIOU of 95.73%. Further, the proposed model was also evaluated on k-fold cross-validation and achieved 99.097% accuracy on fold-5. This proposed system shows superiority over already existing methods in terms of performance evaluation parameters.

18 August 2023 in International Journal of Imaging Systems and Technology
Verified
Journal Article
Closed access
Hafiz Muhammad Tayyab KhushiHafiz Muhammad Tayyab Khushi
Hafiz Muhammad Tayyab Khushi
TMTehreem Masood
Tehreem Masood
AJArfan Jaffar
Arfan Jaffar
SASheeraz Akram
Sheeraz Akram
SBSohail Masood Bhatti
Sohail Masood Bhatti

27 May 2025 in IEEE Access
Verified
Journal Article
Open access
WAWishal Arshad
Wishal Arshad
TMtehreem masood
tehreem masood
H M ShahzadH M Shahzad
H M Shahzad
HAHassan A Ahmed
Hassan A Ahmed
SASyed Hamza Ahmed
Syed Hamza Ahmed
Hafiz Muhammad Tayyab KhushiHafiz Muhammad Tayyab Khushi
Hafiz Muhammad Tayyab Khushi
Breast cancer is the second leading cause of mortality among women worldwide, highlighting the need for efficient histopathology-based screening methods for early diagnosis. This study introduces HistoDX, a deep learning framework to classify Invasive Ductal Carcinoma (IDC) using 277,524 histopathology image patches (50x50 pixels) from Paul Mooney’s IDC dataset on Kaggle, comprising No Cancer and IDC(+) classes. HistoDX employs a preprocessing pipeline with normalization, data augmentation, and class balancing via oversampling and weighted loss to address the class imbalance. A customized convolutional neural network, built on EfficientNetV2-B3 with additional layers, achieves 97% accuracy and a 0.91 ROC-AUC score on the test set. Validation on BreakHis (97% accuracy) and BACH (90% accuracy) datasets confirm generalizability, though detecting minority IDC(+) cases remains challenging. Low training and test losses underscore reliability. HistoDX empowers pathologists by enhancing diagnostic efficiency and minimizing subjectivity through effective class imbalance mitigation. Its robust performance across diverse datasets like BreakHis and BACH suggests readiness for clinical integration. Future research into advanced augmentation techniques, ensemble models, and whole-slide image analysis could further optimize accuracy, sensitivity, and scalability, paving the way for broader adoption in precision oncology.

27 November 2024 in Computers
Verified
Journal Article
Open access
PDF file
Ahmed HassanAhmed Hassan
Ahmed Hassan
TMtehreem masood
tehreem masood
HAHassan A Ahmed
Hassan A Ahmed
H M ShahzadH M Shahzad
H M Shahzad
Hafiz Muhammad Tayyab KhushiHafiz Muhammad Tayyab Khushi
Hafiz Muhammad Tayyab Khushi
Speech emotion recognition (SER) is an emerging technology that utilizes speech sounds to identify a speaker’s emotional state. Computational intelligence is receiving increasing attention from academics, health, and social media applications. This research was conducted to identify emotional states in verbal communication. We applied a publicly available dataset called RAVDEES. The data augmentation process involved adding noise, applying time stretching, shifting, and pitch, and extracting the features zero cross rate (ZCR), chroma shift, Mel-Frequency Cepstral Coefficients (MFCC), and a spectrogram. In addition, we used many pretrained deep learning models, such as VGG16, ResNet50, Xception, InceptionV3, and DenseNet121. Out of all of the deep learning models, Xception yielded superior outcomes. Furthermore, we improved performance by changing the Xception model to include hyperparameters and additional layers. We used a variety of performance evaluation parameters to test the proposed model. These included F1-score, accuracy, misclassification rate (MCR), precision, sensitivity, specificity, negative predictive value, false negative rate, false positive rate, false discovery rate, false omission rate, and false discovery rate. The model that we suggested demonstrated an overall accuracy of 98%, with an MCR of 2%. Additionally, it attained precision, sensitivity, and specificity values of 91.99%, 91.78%, and 98.68%, respectively. Additional models attained an F1-score of 91.83%. Our suggested model demonstrated superiority compared to other cutting-edge techniques

1 January 2024 in Brazilian Archives of Biology and Technology
Verified
Journal Article
Open access
PDF file
Hafiz Muhammad Tayyab KhushiHafiz Muhammad Tayyab Khushi
Hafiz Muhammad Tayyab Khushi
TMtehreem masood
tehreem masood
AJArfan Jaffar
Arfan Jaffar
SASheeraz Akram
Sheeraz Akram
World's deadliest disease is brain tumor. Misdiagnosed cancers and inadequate treatment reduce survival. However, magnetic resonance imaging (MRI) is utilized for tumor analysis, but the enormous number of pictures produced by MRI makes it time-consuming and difficult to diagnose a patient just because of its complex nature, putting their life at risk. Thus, accurately detecting early brain cancers manually is difficult. We need an autonomous, intelligent system to detect brain cancers early and accurately. This study proposes a pre-trained EfficientNetb4 model with an adjusttable learning rate and custom callback to efficiently classify tumors. The proposed methodology improves the quality and quantity of the publicly accessible Br35h dataset by applying data augmentation techniques. The suggested model had 99.67% accuracy on Br35h data and 0.33% miss categorization. This method, however, had 99.87% accuracy on supplemented data and 0.13% miss categorization. The system achieves 99.33%, 99.97%, 99.93%, 99.33%, 0.66%, and 99.66% for Br35h in sensitivity, specificity, precision, NPV, FOR, and F1-score. The suggested model had 99.97% sensitivity, 99.74% specificity, 99.74% accuracy, 100% NPV, 0.66% FOR, and 99.66% F1-score for the Br35h-augmented dataset. Further, the proposed model also achieved FNR and FPR of 0 and 0.26%, respectively, and the augmented Br35H dataset achieved FNR and FPR of 0.66% and 0%, respectively. The 5Flod cross-validation also found that the model achieved an overall validation accuracy of 98.606% with a loss of 0.224%. Regarding results, the proposed system shows superior performance to other state-of-the art approaches.

29 March 2025
Verified
Book Chapter
Closed access
PDF file
SISyed Muhammad Ali Imran
Syed Muhammad Ali Imran
MAMuhammad Arif
Muhammad Arif
AJArfan Jaffar
Arfan Jaffar
Hafiz Muhammad Tayyab KhushiHafiz Muhammad Tayyab Khushi
Hafiz Muhammad Tayyab Khushi
AHAbida Hussain
Abida Hussain