This study investigates experimentally and numerically the effects of sills with different geometric specifications at various positions on the hydraulic characteristics of flow through sluice gates. The simulation results showed that the RNG turbulence model’s statistical indicators yield high accuracy compared to the k-ε, k-ω, and LES turbulence models. The discharge coefficient (Cd) has an inverse relationship with gate opening. Regarding sill state, the discharge coefficient is higher than no-sill state. In the case of non-suppressed sills, the Cd decreases compared to the smaller openings as the opening of the gate changes. The results showed that the Cd with a sill in the tangent position upstream of the gate is higher than the downstream tangent and below situations. Increasing the sill length leads to an increase in flow shear stress and consequently a decrease in Cd. The Cd of gates with different sill thicknesses is always higher than the no-sill state, but due to the constant ratio of the fluid depth above the sill to the gate opening, the Cd increases to a certain extent and then decreases with increasing sill thickness.
23 February 2024 in AQUA — Water Infrastructure, Ecosystems and Society
This investigation focuses on flow energy, a crucial parameter in the design of water structures such as channels. The research endeavors to explore the relative energy loss (ΔEAB/EA) in a constricted flow path of varying widths, employing Support Vector Machine (SVM), Artificial Neural Network (ANN), Gene Expression Programming (GEP), Multiple Adaptive Regression Splines (MARS), M5 and Random Forest (RF) models. Experiments span a Froude number range from 2.85 to 8.85. The experimental findings indicate that the ΔEAB/EA exceeds that observed in a classical hydraulic jump with constriction section. Within the SVM model, the linear kernel emerges as the best predictor of ΔEAB/EA, outperforming polynomial, radial basis function (RBF), and sigmoid kernels. In addition, in the ANN model, the MLP network was more accurate compared to the RBF network. The results indicate that the relationship proposed by the MARS model can play a significant role resulting in high accuracy compared to the non-linear regression relationship in predicting the target parameter. Upon comprehensive evaluation, the ANN method emerges as the most promising among the candidates, yielding superior performance compared to the other models. The testing phase results for the ANN-MLP are noteworthy, with R = 0.997, average RE% = 0.63%, RMSE = 0.0069, BIAS = −0.0004, DR = 0.999, SI = 0.0098 and KGE = 0.995.
25 November 2024 in AQUA — Water Infrastructure, Ecosystems and Society
Overflow structures are among the most important hydraulic structures used for measuring flow, controlling floods in reservoirs, and regulating water levels in open channels. Alternative options, such as combined structures like spillway-gates, are preferred due to their compatibility with natural and ecological needs. This study investigates the impact of different soil gradations downstream on the scouring profile of combined spillway-gate structures. Scouring and sedimentation downstream of the spillway-gate were examined under various particle sizes of 0.0008, 0.001, and 0.0014 m, with a constant density in both free and submerged flow conditions using the FLOW-3D software. In this study, the k-ε, k-ω, LES, and RNG turbulence models were evaluated, and the RNG turbulence model was selected among that group. In free flow conditions, the highest sediment deposition occurred with the smallest particle diameter. For larger particle diameters, the void spaces between the particles reduce friction and increase the movement threshold, leading to increased scouring and decreased sediment height. In submerged flow conditions, the changes in scouring for different particle sizes were minor, with results being closely aligned. In submerged flow conditions, increasing the particle diameter resulted in a decrease in sediment deposition in the post-scouring area.
Viable renewable energy sources must be low-cost, easy to install, clean, and reliable if they are to meet the energy demand of urban or rural areas. Water is able to provide efficient sources of electrical energy among alternative renewable energy sources. Using modern hydraulic techniques, drinking water can be transported to the areas where it is needed. Studies on obtaining energy from drinking water networks are quite limited. Although not as necessary as water in terms or human health, electrical power is still critically important in many applications (lighting, heating, cooling, etc.). Consequently, many countries are developing energy using various renewable energy sources. In this study, a water distribution network in the Armağan Village of Maçka district of Trabzon province were used to obtain electrical energy. There are 47 pressure breaking valves (PBVs) in this network and the broken energy height is 236.35 m. The same energy loss can be achieved by installing microturbines instead of PBVs, and electricity generation can thus be achieved with a clean energy source. It was found that 84.12kWh of energy was obtained from each PBV, with a total of 3950kWh. The most suitable microturbine was selected according to sound microturbine selection criteria. From this study, it is revealed that electricity can be produced by using a Microturbine instead of Pressure Breaker Valves (PBVs).
This study investigates the effects of gate openings and different sill widths on the sluice gate’s energy dissipation and discharge coefficient (Cd). The physical model of the sills includes rectangular sills of different dimensions. The results show that the gate opening size is inversely related to the Cd for a gate without a sill. In addition, increasing the gate opening size for a given discharge decreases the relative energy dissipation, and increasing the Froude number increases the relative energy dissipation. The results also show that the Cd and relative energy dissipation decrease when the width of the sill is decreased, thus increasing the total area of the flux flowing through the sluice gate and vice versa. According to the experimental results, the relative energy dissipation and the Cd of the sluice gate are larger for all sill widths than without the sill. Finally, non-linear polynomial relationships are presented based on dimensionless parameters for predicting the relative energy dissipation and outflow coefficient.
16 June 2025 in Multiscale and Multidisciplinary Modeling, Experiments and Design