Hanan Hassan Shaat

Dr. Hanan Hassan Shaat

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2016 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
HSHanan Hassan Shaat
Hanan Hassan Shaat
AMAmany A. Mostafa
Amany A. Mostafa
MMMoustafa Moustafa
Moustafa Moustafa
AGAmira M. Gamal-Eldeen
Amira M. Gamal-Eldeen
AEAhmed Nabile Emam
Ahmed Nabile Emam
MEMahmoud ElHefnawi
Mahmoud ElHefnawi

7 November 2024 in Analytica Chimica Acta
Verified
Journal Article
Open access
HSHanan Hassan Shaat
Hanan Hassan Shaat
MSMohamed Sharafeldin
Mohamed Sharafeldin
AMAmany Mostafa
Amany Mostafa
EIEman H. Ismail
Eman H. Ismail
MHMohmed K. Hassan
Mohmed K. Hassan
SSsherif Shawky
sherif Shawky
Hepatitis C Virus (HCV) is an asymptomatic chronic infection with serious clinical consequences. Timely and sensitive detection of HCV RNA is critical for infection control, treatment response follow up. While current technologies, such as PCR or isothermal amplification-based strategies, are specific, they are expensive, labor intensive, time consuming limiting their use in field and small laboratories. We introduce a novel technology for detecting nucleic acids, as exemplified by HCV RNA, in clinical specimens. This approach utilizes the crosslinked Enhanced Emission (CEE) phenomena upon mixing fluorescent amino functionalized silica-coated nitrogen-doped carbon dots (N-CDs/SiO2/NH2) with magnetic extracted unamplified HCV RNA showed a significant and immediate fluorescence enhancement. This method was integrated into a semi-automated 3D printed microfluidic chip, wherein the unamplified RNA was mixed with the N-CDs/SiO2/NH2. The assay was also employed on the conventional 96-well plate format. This assay offers high sensitivity with detection limit of 500 IU/ml and 1000 IU/ml for the chip and well plate respectively. The sample-to-result time was <20 min on the chip and is simpler than the amplification-based techniques. Analyzing 141 patient samples yielded sensitivity and specificity of 96.47 % and 98.79 % respectively. This application of N-CDs/SiO2 as nucleic acid fluorescent probes for the first time, offers a versatile, cost-effective, and universal platform for nucleic acids detection. The developed system can be employed in conventional microwell plate-based detection with minimal modifications to current laboratory setups. Additionally, it was integrated into a 3D-printed microfluidic chip enabling enhancement in specificity, sensitivity and accuracy.

13 August 2025 in IEEE Access
Verified
Journal Article
Open access
RAReda Abdelbaset
Reda Abdelbaset
YEYehia El-Sehrawy
Yehia El-Sehrawy
HSHanan Hassan Shaat
Hanan Hassan Shaat
SSSherif M. Shawky
Sherif M. Shawky
MAMohammed A. A. Abdullah
Mohammed A. A. Abdullah
YIYehea Ismail
Yehea Ismail
Flow Cytometry (FC) is a powerful technique used to detect and measure various cellular characteristics, including size, count, morphology, and DNA content. It plays a vital role in clinical diagnostics and biomedical research, with widespread use in hospitals and medical institutions worldwide. In this work, an on-chip, capacitance-based flow cytometer is developed to manipulate, characterize, detect, and quantify microbeads based on their electrical properties, specifically, capacitance. The proposed biochip consists of two primary subsystems: a manipulation system for directing particles and a detection system for characterizing them. The manipulation system integrates a microfluidic flow control design with dielectrophoresis (DEP) microelectrodes. DEP enables label-free particle manipulation in non-uniform electric fields by inducing polarization, allowing for precise control of particle trajectories with minimal sample preparation. The detection system employs a capacitive sensor array coupled with a ring oscillator-based readout circuit for real-time electrical sensing. Capacitance-based biosensors offer rapid, accurate, and efficient detection without the need for bulky optical equipment or chemical labeling. Leveraging printed circuit board (PCB) technology, the DEP electrodes and capacitive sensors are seamlessly integrated into a compact, low-cost, and scalable platform. The inclusion of a gold surface further enhances electrical conductivity and biocompatibility, making the system suitable for biological applications. Experimental and simulation results confirm that the integrated manipulation and sensing components effectively characterize and quantify carboxylate polystyrene microbeads. The sensor exhibits high sensitivity, achieving 184 fF per 1% w/v concentration change, and demonstrates excellent linearity with a coefficient of determination (R2) of 0.9755, indicating a reliable and consistent response. The use of a 7-stage Miller ring oscillator enables precise capacitance-to-frequency conversion with minimal error, achieving a root mean square error (RMSE) of 0.57 across a capacitance range of 1–100 pF. This allows for reliable detection of concentrations as low as 0.15625% w/v.