Hassan Reza Mirzaei

Dr. Hassan Reza Mirzaei

University of Zanjan, Zanjān, Iran
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2015 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Hassan Reza MirzaeiHassan Reza Mirzaei
Hassan Reza Mirzaei
AAA. Akbari
A. Akbari
EGE. Gockenbach
E. Gockenbach
KMK. Miralikhani
K. Miralikhani
Partial discharge (PD) detection in the ultra-high frequency (UHF) range is state of the art. One of the most critical points in this detection method is adopting proper and suitable antenna design. In this paper, a new design of UHF antennas is introduced which is suitable to be used on the transformers in the HV laboratories of the manufacturers. To ensure the applicability of the new antenna, experimental UHF PD measurements are carried out on a transformer tank model as well as on the real power transformers. Installing several UHF antennas on the transformer tank to perform defect localization is also an important issue. There are rigorous limitations and lack of the places to install the antennas. This problem is almost solved by using the mentioned new antenna design. The proper positioning of the antennas is the other critical point in the UHF method. Placing the antennas in improper positions will damage the localization accuracy. In this paper, an automatic algorithm is introduced to determine the best installation positions for the antennas to enhance the localization accuracy. The efficacy of this algorithm is investigated by using the results of experimental measurements on power transformers.

8 February 2013 in IEEE Electrical Insulation Magazine
Verified
Journal Article
Closed access
Hassan Reza MirzaeiHassan Reza Mirzaei
Hassan Reza Mirzaei
AAAsghar Akbari
Asghar Akbari
EGErnst Gockenbach
Ernst Gockenbach
MZMojtaba Zanjani
Mojtaba Zanjani
KMKarim Miralikhani
Karim Miralikhani
Nowadays, the localization of partial discharge (PD) in power transformers by measurement of ultra-high-frequency (UHF) electromagnetic (EM) waves from a PD source is receiving more attention. This method is based on comparing the differences in the arrival times, to antennas in the transformer, of EM waves emitted from the PD source. From the measured UHF signal, and factoring in the influence of the transformer active part on the EM wave propagation, the correct determination of an EM wave arrival time in the localization algorithm is a critical task that influences the accuracy of the UHF PD localization method. Nearly all weak points in the dielectric system of power transformers generate PD. These discharges gradually degrade the insulation, leading to transformer failure. It is possible to detect these defects in the early stages of PD generation by measuring and analyzing the PD data. Suitable maintenance and repair strategies can then be implemented.

25 February 2016 in IEEE Electrical Insulation Magazine
Verified
Journal Article
Closed access
AAAsghar Akbari
Asghar Akbari
PWPeter Werle
Peter Werle
MAMohammad Akbari Azirani
Mohammad Akbari Azirani
Hassan Reza MirzaeiHassan Reza Mirzaei
Hassan Reza Mirzaei
The detection and measurement of partial discharge (PD) is a well-known method for evaluating the insulation performance of power transformers. According to the IEC 60270 standard, the apparent charge is measured in a frequency range below 1 MHz using an electrical circuit which quantifies only a portion of the discharge energy conducted to the PD detector through the conductors. However, it is also well known that the PD energy is not only conducted but also transmitted via electromagnetic (EM) and optic waves, acoustic waves, and thermal energy. This article describes the significant challenges and the problem of calibrating the ultrahigh frequency partial discharge measurement method for power transformers and clarifies the complexities theoretically and experimentally.

26 February 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SSSajjad Sharifinia
Sajjad Sharifinia
MAMehdi Allahbakhshi
Mehdi Allahbakhshi
TGTeymoor Ghanbari
Teymoor Ghanbari
AAAsghar Akbari
Asghar Akbari
Hassan Reza MirzaeiHassan Reza Mirzaei
Hassan Reza Mirzaei
This paper deals with a new high efficient and cost effective lattice-Rogowski-coil sensor for partial discharge monitoring of power transformers. The sensor is a thin flat-shape printed circuit board type Rogowski-coil, which can be installed on the internal surface of the transformer tank with minimum disturbance to the normal operation of the transformer. Thanks to the accurate and desirable geometry of the sensor, precise monitoring can be carried out. Also, it was designed to handle the common trade-off between the low resonant frequency and high mutual inductance. An experimental setup for measuring the lumped model parameters of the sensor is made and it is shown that the desired resonance frequency of approximately 10 MHz is obtained. In order to evaluate the performance of the sensor, a specially prepared distribution transformer (20 kV/0.4 kV, 500 kVA) was considered. Partial discharge calibration pulses were injected into different locations of the winding of this transformer, and the ability of the sensor was verified in defect localization. Moreover, the effects of some practical aspects, like the value of the terminating resistor of the proposed special Rogowski-coil, its distance from transformer winding as well as the capability of the extracted features from detected PD signals, on the accuracy of PD localization are studied.

3 November 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Mohammad KharezyMohammad Kharezy
Mohammad Kharezy
Hassan Reza MirzaeiHassan Reza Mirzaei
Hassan Reza Mirzaei
YSYuriy Serdyuk
Yuriy Serdyuk
TTTorbjörn Thiringer
Torbjörn Thiringer
MEMorteza Eslamian
Morteza Eslamian
Offshore wind farms pose the challenge of transmission of produced energy in an economic and effective way over long distances, justifying investments in High Voltage Direct Current (HVDC) systems. A solution to surmount the need for an expensive and large power transformer station is to connect each wind turbine to a DC/DC converter in which a Medium Frequency Transformer (MFT) is utilized to reduce the size of the station. Further, the DC outputs of the converters of the wind turbines can be connected in series to create a high DC voltage. In this solution, the MFTs are required to be insulated against a high DC voltage to ground in a limited compartment. This contribution presents a prototype of a 50 kW oil-paper insulated MFT operating at biased 422/4500 V/V AC 5 kHz and 125 kV DC test voltage, which has been manufactured and subjected to verification HV tests. The dielectric design of the prototype MFT based on finite element solution of non-linear Maxwell-Wagner equations is introduced and the acceptance criteria and practical design considerations are discussed.

8 August 2008 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
AJA. Mazhab Jafari
A. Mazhab Jafari
AAA. Akbari
A. Akbari
Hassan Reza MirzaeiHassan Reza Mirzaei
Hassan Reza Mirzaei
MKM. Kharezi
M. Kharezi
MAM. Allahbakhshi
M. Allahbakhshi
One of the well-known methods of partial discharge (PD) localization in transformers is based on winding modeling. Although the method is theoretically precise, the reliability of the method is not known in practice, because of the difficulties that arise in high frequency modeling of the winding. In this paper, to investigate the reliability of the PD localization method in practical cases, different types of PD including PD in air, PD in paper voids, PD in oil gaps and surface PD along insulator are produced. A 20 kV/0.4 kV research transformer with 6 accessible clamps along its winding and a specially prepared 63 kV winding with 30 accessible clamps are used as test objects. The generated PD pulses are injected to different clamps of the test objects and recorded at both ends of the windings by means of a wideband modern PD measuring system. A modified method based on using multi conductor transmission line model (MTLM) of transformer winding is used as PD localization method and to increase the reliability of the results, a method based on using calibration pulses is proposed. At last, the accuracy of PD localization results in the two test objects is investigated.