Objective: The objectives of this study were to (1) investigate whether electrodiagnostic (EDX) findings reflect the preoperative symptom severity and functional impairment in patients with carpal tunnel syndrome (CTS) and (2) evaluate the relationship between EDX findings and the clinical outcomes reported according to the self-administered patient questionnaires. Methods: Patients diagnosed with idiopathic CTS who underwent carpal tunnel release between May 2016 and July 2018 were included. Carpal tunnel syndrome was clinically diagnosed and confirmed based on the EDX findings. The association between EDX findings, such as motor latency, motor amplitude, sensory latency, sensory amplitude, and severity (mild, moderate, and severe), and the Boston symptom and function scores were analyzed. The change in the Boston symptom and function scores from the preoperative baseline values (visit 1) to those recorded 1 year postoperatively (visit 5) was assessed. The effect of disease severity based on the EDX findings on the change in Boston symptom and function scores by visit was also investigated. Results: The EDX severity, motor latency, motor amplitude, sensory latency, and sensory amplitude were not correlated with the Boston symptom and function scores preoperatively and postoperatively. Electrodiagnostic severity did not affect the improvement in the Boston symptom and function scores recorded at each visit. Conclusion: We found no association between the EDX severity and perioperative Boston questionnaire scores, and the degree of improvement in patient symptoms and function did not differ according to the CTS severity based on the EDX findings. Level of Evidence: Level IV, Prognostic study Cite this article as: Koo JH, Bae J, Lee K, Park HS. Correlation between electrodiagnostic severity and Boston carpal tunnel questionnaire in surgically treated carpal tunnel syndrome patients. Acta Orthop Traumatol Turc., 2023;57(6):357-360.
Introduction: Assessing patient expectations in orthopaedic surgery has gained significant importance over time. However, there have been only a few studies on how to measure such expectations in hand surgery. Against the backdrop, the study was designed to develop a valid and reliable expectations survey for patients undergoing hand surgery and to identify the correlations between preoperative expectations and postoperative satisfaction. Materials and methods: This is a three-phase prospective cohort study. In the first phase of the study (146 patients), patient expectations were assessed while developing a draft questionnaire based on frequency and clinical relevance. In the second phase (154 patients newly included), test-retest reliability was measured to ensure test consistency. The Intraclass Correlation Coefficient (ICC) served as a basis for developing the final survey questionnaire. In the third phase, we followed up with patients, who completed the preoperative expectations survey, 3 months after surgery to assess the fulfillment of their expectations. The Pearson correlation method was used to measure the association between preoperative expectations and postoperative satisfaction. Results: In the first phase, 146 patients shared 406 different expectations, which were grouped into nine categories. Then, in the second phase, the final survey was populated by questionnaire items under respective category that have revealed strong test-retest reliability (ICC of 0.91). A significant positive correlation between patient expectations and satisfaction was observed (R = 0.181, p = 0.034). Conclusion: The survey was designed to offer a valid and reliable approach for the comprehensive assessment of patient expectations in hand surgery. The survey results show that patients with high expectations tend to be more satisfied with surgical outcomes. It is strongly believed that this approach would serve as a useful tool at a time when patient perspective is taken into account increasingly more in the clinical practice.
Hallux valgus is a common foot and ankle disease, for which numerous surgical procedures were introduced. So, understanding the mechanism of deformity reduction is important to select the proper method. Intermetatarsal angle (IMA) determines the severity of hallux valgus, which is influenced by the translated metatarsal head and the reduction of the first tarsometatarsal joint. We hypothesized that both of the mechanisms simultaneously contribute to the correction of IMA. Hallux valgus (70 feet) operated with a Scarf osteotomy with the Akin procedure were reviewed. Hallux valgus angle (HVA), IMA (mechanical and anatomical), hallux valgus interphalangeal angle (HVIP), distal metatarsal articular angle (DMAA), and sesamoid position were checked. The ratio of contributions to the IMA changes were calculated and compared. When the individual contributions by metatarsal head translation and first tarsometatarsal joint reduction were compared, metatarsal head translation contributed by 82%, whereas first tarsometatarsal joint reduction contributed by 18%. Both were responsible for mechanical IMA correction. However, IMA change by metatarsal head translation was a major correction mechanism compared to anatomical IMA change by first tarsometatarsal joint reduction.
Purpose: During volar plate fixation of distal radius fractures, we have encountered patients with an anomalous course of the palmar cutaneous branch (PCB) of the median nerve within the sheath of the flexor carpi radialis (FCR) tendon. The purpose of this study was to assess the frequency and location of variations of the PCB within the sheath of the FCR tendon.Methods: This retrospective study enrolled 83 patients who underwent volar locking plate fixations through a modified Henry approach for distal radius fractures from July 2018 to April 2020. When we encountered an anomalous PCB within the sheath of the FCR tendon, we documented the specific finding and location where the PCB entered the sheath of the FCR tendon.Results: There were nine patients (10.8%) who had an anomalous course of PCB penetrating the sheath of the FCR tendon. The average entering point of PCB into the sheath of the FCR tendon was 3.07 cm from the distal wrist crease (range, 2.5–3.6 cm).Conclusion: An anomalous course of the PCB entering the sheath of the FCR tendon was observed at a high frequency (10.8%). Care must be taken not to injure the PCB during a dissecting of the FCR sheath during a modified Henry approach for a distal radius fracture.