Henk-Willem Veltkamp

Mr. Henk-Willem Veltkamp

Integrated Devices and Systems, MESA+ Institute for Nanotechnology, University of Twente
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
SKShirin Azadi Kenari
Shirin Azadi Kenari
RWRemco Wiegerink
Remco Wiegerink
HVHenk-Willem Veltkamp
Henk-Willem Veltkamp
RSRemco G. P. Sanders
Remco G. P. Sanders
JLJoost Lötters
Joost Lötters
This paper presents a novel gas-independent thermal flow sensor chip featuring three calorimetric flow sensors for measuring flow profile and direction within a tube, along with a single-wire flow independent thermal conductivity sensor capable of identifying the gas type through a simple DC voltage measurement. All wires have the same dimensions of 2000 μm in length, 5 μm in width, and 1.2 μm in thickness. The design theory and COMSOL simulation are discussed and compared with the measurement results. The sensor’s efficacy is demonstrated with different gases, He, N2, Ar, and CO2, for thermal conductivity and thermal flow measurements. The sensor can accurately measure the thermal conductivity of various gases, including air, enabling correction of flow rate measurements based on the fluid type. The measured voltage from the thermal conductivity sensor for air corresponds to a calculated thermal conductivity of 0.02522 [W/m·K], with an error within 2.9%.

25 February 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
HVHenk-Willem Veltkamp
Henk-Willem Veltkamp
FMFernanda Akegawa Monteiro
Fernanda Akegawa Monteiro
RSRemco G. P. Sanders
Remco G. P. Sanders
RWRemco Wiegerink
Remco Wiegerink
JLJoost Lötters
Joost Lötters
Fast point-of-use detection of, for example, early-stage zoonoses, e.g., Q-fever, bovine tuberculosis, or the Covid-19 coronavirus, is beneficial for both humans and animal husbandry as it can save lives and livestock. The latter prevents farmers from going bankrupt after a zoonoses outbreak. This paper describes the development of a fabrication process and the proof-of-principle of a disposable DNA amplification chip with an integrated heater. Based on the analysis of the milling process, metal adhesion studies, and COMSOL MultiPhysics heat transfer simulations, the first batch of chips has been fabricated and successful multiple displacement amplification reactions are performed inside these chips. This research is the first step towards the development of an early-stage zoonoses detection device. Tests with real zoonoses and DNA specific amplification reactions still need to be done.

4 November 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
HVHenk-Willem Veltkamp
Henk-Willem Veltkamp
YJYves Janssens
Yves Janssens
MBMeint J. de Boer
Meint J. de Boer
YZYiyuan Zhao
Yiyuan Zhao
RWRemco Wiegerink
Remco Wiegerink
JLJoost Lötters
Joost Lötters
In micro-machined micro-electromechanical systems (MEMS), refilled high-aspect-ratio trench structures are used for different applications. However, these trenches often show keyholes, which have an impact on the performance of the devices. In this paper, explanations are given on keyhole formation, and a method is presented for etching positively-tapered high-aspect ratio trenches with an optimised trench entrance to prevent keyhole formation. The trench etch is performed by a two-step Bosch-based process, in which the cycle time, platen power, and process pressure during the etch step of the Bosch cycle are studied to adjust the dimensions of the scallops and their location in the trench sidewall, which control the taper of the trench sidewall. It is demonstrated that the amount of chemical flux, being adjusted by the cycle time of the etch step in the Bosch cycle, relates the scallop height to the sidewall profile angle. The required positive tapering of 88° to 89° for a keyhole-free structure after a trench refill by low-pressure chemical vapour deposition is achieved by lowering the time of the etch step.

18 March 2020 in Molecules
Verified
Journal Article
Open access
PDF file
HRHoon Suk Rho
Hoon Suk Rho
HVHenk-Willem Veltkamp
Henk-Willem Veltkamp
AHAlexander Thomas Hanke
Alexander Thomas Hanke
MOMarcel Ottens
Marcel Ottens
CBChristian Breukers
Christian Breukers
HGHan Gardeniers
Han Gardeniers
A microfluidic protein aggregation device (microPAD) that allows the user to perform a series of protein incubations with various concentrations of two reagents is demonstrated. The microfluidic device consists of 64 incubation chambers to perform individual incubations of the protein at 64 specific conditions. Parallel processes of metering reagents, stepwise concentration gradient generation, and mixing are achieved simultaneously by pneumatic valves. Fibrillation of bovine insulin was selected to test the device. The effect of insulin and sodium chloride (NaCl) concentration on the formation of fibrillar structures was studied by observing the growth rate of partially folded protein, using the fluorescent marker Thioflavin-T. Moreover, dual gradients of different NaCl and hydrochloric acid (HCl) concentrations were formed, to investigate their interactive roles in the formation of insulin fibrils and spherulites. The chip-system provides a bird’s eye view on protein aggregation, including an overview of the factors that affect the process and their interactions. This microfluidic platform is potentially useful for rapid analysis of the fibrillation of proteins associated with many misfolding-based diseases, such as quantitative and qualitative studies on amyloid growth.

30 September 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
QYQihui Yu
Qihui Yu
HVHenk-Willem Veltkamp
Henk-Willem Veltkamp
RWRemco Wiegerink
Remco Wiegerink
JLJoost Lötters
Joost Lötters
In this paper, a novel fabrication process for the realization of large, suspended microfluidic channels is presented. The method is based on Buried Channel Technology and uses a mixture of HF, HNO3, and water etchant, which has high selectivity between the silicon substrate and the silicon-rich silicon nitride mask material. Metal electrodes for actuation and read-out are integrated into the fabrication process. The microfluidic channels are released from the silicon substrate to allow the vibrational movement needed for the application. The resulting microfluidic channels have a near-circular cross-section, with a diameter up to 300 μm and a channel wall thickness of 1.5 μm. The structure of a micro-Coriolis mass-flow and density sensor is fabricated with this process as an example of a possible application.

28 January 2019 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Open access
PDF file
DJDirk Jonker
Dirk Jonker
HVHenk-Willem Veltkamp
Henk-Willem Veltkamp
RSR G P Sanders
R G P Sanders
SSStefan Schlautmann
Stefan Schlautmann
KGKatharine Giannasi
Katharine Giannasi
HGHan Gardeniers
Han Gardeniers
The pressure stability of microfluidic glass chips was tested experimentally, with a special focus on the inserts for glued capillary connections. Destructive high-pressure experiments with demineralized water conducted at room temperature showed a difference in mean fracture pressure between the two tested glass types BF33 and D263T, with values of 192 ± 25 and 159 ± 25 bar, respectively. For BF33, hydrofluoric acid (HF) etching of the powder blasted (abrasive jet machined) chip insert increased the mean fracture pressure with 43 ± 9 bar, whilst for D263T a decrease of −22 ± 8 bar resulted. Contrary to the expected surface smoothening of the HF treatment, a rougher surface was obtained, particularly for the case of D263T, which is thought to be due to the opening of median (radial) cracks caused by the powder impact during the blasting process. The roughness obscures the effect of the tapering of the insert, preventing that factor from having a statistically significant effect on the mean fracture pressure. Nevertheless, a decrease in the mean fracture pressure and a decrease in the variance of the mean fracture pressure was observed when a taper is introduced, whereas the fracture location tends to move away from the insert-microchannel intersection towards the glue meniscus. A practical solution for cases where a high-pressure stability is required is found in applying a metal clamp around the capillary insert section. This significantly increased the fracture pressure of the chip insert section with 50 ± 21 bar, by preventing bond release.