The early detection and diagnosis of breast cancer may increase survival rates and reduce overall treatment costs. The cancer of the breast is a severe and potentially fatal disease that impacts individuals worldwide. Mammography is a widely utilized imaging technique for breast cancer surveillance and diagnosis. However, images produced with mammography frequently contain noise, poor contrast, and other anomalies that hinder radiologists from interpreting the images. This study develops a novel deep-learning technique for breast cancer detection using mammography images. The proposed procedure consists of two primary steps: region-of-interest (ROI) (1) extraction and (2) classification. At the beginning of the procedure, a YOLOX model is utilized to distinguish breast tissue from the background and to identify ROIs that may contain lesions. In the second phase, the EfficientNet or ConvNeXt model is applied to the data to identify benign or malignant ROIs. The proposed technique is validated using a large dataset of mammography images from various institutions and compared to several baseline methods. The pF1 index is used to measure the effectiveness of the technique, which aims to establish a balance between the number of false positives and false negatives, and is a harmonic mean of accuracy and recall. The proposed method outperformed existing methods by an average of 8.0%, obtaining superior levels of precision and sensitivity, and area under the receiver operating characteristics curve (ROC AUC) and the precision–recall curve (PR AUC). In addition, ablation research was conducted to investigate the effects of the procedure’s numerous components. According to the findings, the proposed technique is another choice that could enhance the detection and diagnosis of breast cancer using mammography images.
The development of optical sensors, especially with regard to the improved resolution of cameras, has made optical techniques more applicable in medicine and live animal research. Research efforts focus on image signal acquisition, scattering de-blur for acquired images, and the development of image reconstruction algorithms. Rapidly evolving artificial intelligence has enabled the development of techniques for de-blurring and estimating the depth of light-absorbing structures in biological tissues. Although the feasibility of applying deep learning to overcome these problems has been demonstrated in previous studies, limitations still exist in terms of de-blurring capabilities on complex structures and the heterogeneity of turbid medium, as well as the limit of accurate estimation of the depth of absorptive structures in biological tissues (shallower than 15.0 mm). These problems are related to the absorption structure’s complexity, the biological tissue’s heterogeneity, the training data, and the neural network model itself. This study thoroughly explores how to generate training and testing datasets on different deep learning models to find the model with the best performance. The results of the de-blurred image show that the Attention Res-UNet model has the best de-blurring ability, with a correlation of more than 89% between the de-blurred image and the original structure image. This result comes from adding the Attention gate and the Residual block to the common U-net model structure. The results of the depth estimation show that the DenseNet169 model shows the ability to estimate depth with high accuracy beyond the limit of 20.0 mm. The results of this study once again confirm the feasibility of applying deep learning in transmission image processing to reconstruct clear images and obtain information on the absorbing structure inside biological tissue. This allows the development of subsequent transillumination imaging studies in biological tissues with greater heterogeneity and structural complexity.
16 January 2022 in Kalpa Publications in Engineering
Diabetic retinopathy (DR) is a complication of diabetes mellitus that causes retinal damage that can lead to vision loss if not detected and treated promptly. The common diagnosis stages of the disease take time, effort, and cost and can be misdiagnosed. In the recent period with the explosion of artificial intelligence, deep learning has become the most popular tool with high performance in many fields, especially in the analysis and classification of medical images. The Convolutional Neural Network (CNN) is more widely used as a deep learning method in medical imaging analysis with highly effective. In this paper, the five-stage image of modern DR (healthy, mild, moderate, severe, and proliferative) can be detected and classified using the deep learning technique. After cross-validation training and testing on the corresponding 5,590-image dataset, a pre-MobileNetV2 training model is proposed in classifying stages of diabetic retinopathy. The average accuracy of the model achieved was 93.89% with the precision of 94.00%, recall 92.00% and f1-score 90.00%. The corresponding thermal image is also given to help experts for evaluating the influence of the retina in each different stage.
This research investigates the critical role of frequency selection in Electrical Impedance Tomography (EIT), a non-invasive imaging technique that reconstructs internal conductivity distributions through injected electrical currents. Empirical frequency selection is paramount to maximizing the fidelity and specificity of EIT images. The study explores the impact of distinct frequency ranges—low, medium, and high—on image contrast and clarity, particularly focusing on differentiating conductive materials from non-conductive materials. The findings reveal distinct empirical frequency bands for enhancing the respective contrasts: 15–38 kHz for conductive materials (copper) and 45–75 kHz for non-conductive materials (acrylic resin). These insights shed light on the frequency-dependent nature of material contrast in EIT images, guiding the selection of empirical operating ranges for various target materials. This research paves the way for improved sensitivity and broader applicability of EIT in diverse areas.
Recent studies in transillumination imaging for developing an optical computed tomography device for small animal and human body parts have used deep learning networks to suppress the scattering effect, estimate depth information of light-absorbing structures, and reconstruct three-dimensional images of de-blurred structures. However, they still have limitations, such as knowing the information of the structure in advance, only processing simple structures, limited effectiveness for structures with a depth of about 15 mm, and the need to use separated deep learning networks for de-blurring and estimating information. Furthermore, the current technique cannot handle multiple structures distributed at different depths next to each other in the same image. To overcome the mentioned limitations in transillumination imaging, this study proposed a pixel-by-pixel scanning technique in combination with deep learning networks (Attention Res-UNet for scattering suppression and DenseNet-169 for depth estimation) to estimate the existence of each pixel and the relative structural depth information. The efficacy of the proposed method was evaluated through experiments that involved a complex model within a tissue-equivalent phantom and a mouse, achieving a reconstruction error of % compared to the dimensions of the ground truth when using the fully convolutional network. Furthermore, we could use the depth matrix obtained from the convolutional neural network (DenseNet-169) to reconstruct the absorbing structures using a binary thresholding method, which produced a reconstruction error of %. Therefore, only one convolutional neural network (DenseNet-169) must be used for depth estimation and explicit image reconstruction. Therefore, it reduces time and computational resources. With depth information at each pixel, reconstruction of 3D image of the de-blurred structures could be performed even from a single blurred image. These results confirm the feasibility and robustness of the proposed pixel-by-pixel scanning technique to restore the internal structure of the body, including intricate networks such as blood vessels or abnormal tissues.
Monitoring the level of blood glucose is required for diabetes to be managed. Monitoring one's glucose levels with finger prick blood is uncomfortable, unpleasant, and may cause infection. Regularly sticking one's fingers into sharp objects may result in scarring and calluses, reducing sensitivity and perception. Therefore, a blood glucose self-test that is not intrusive is very necessary. The optical blood glucose detection technique is promising and has opportunities for further improvement. This technology makes use of a variety of wavelengths, ranging from ultraviolet to infrared. The skin may be penetrated by low-energy radiation from light with a wavelength ranging from 450 to 2500 nanometers. Changes in light intensity, brought on by glucose's ability to absorb or scatter light, are used to measure blood glucose levels. Despite the extensive research on non-invasive methods, the commercial device is still under development. We summarize the results of experiments utilizing transmission modeling at 660 nm and 780 nm wavelengths. A measurement gadget has been designed to support the finger surveys conducted by volunteers. The VivaChek Ino is used to determine blood glucose levels, which are combined with other measurements to establish the findings of the measurements. The data from fifty different measurements were used to construct the regression lines. The correlation coefficient, R 2 , is close to 0.70. The findings of this research indicate that it would be possible to use an optical approach in conjunction with a transmission model. Additionally, it recommends mixing different near-infrared wavelength ranges to get superior outcomes.