Minh Quan Cao Dinh

Mr. Minh Quan Cao Dinh

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Quoc Tuan Nguyen DiepQuoc Tuan Nguyen Diep
Quoc Tuan Nguyen Diep
Hoang Nhut HuynhHoang Nhut Huynh
Hoang Nhut Huynh
Minh Quan Cao DinhMinh Quan Cao Dinh
Minh Quan Cao Dinh
Huynh Thanh VenHuynh Thanh Ven
Huynh Thanh Ven
ATAnh Tu Tran
Anh Tu Tran
Trung Nghia TranTrung Nghia Tran
Trung Nghia Tran
This research investigates the critical role of frequency selection in Electrical Impedance Tomography (EIT), a non-invasive imaging technique that reconstructs internal conductivity distributions through injected electrical currents. Empirical frequency selection is paramount to maximizing the fidelity and specificity of EIT images. The study explores the impact of distinct frequency ranges—low, medium, and high—on image contrast and clarity, particularly focusing on differentiating conductive materials from non-conductive materials. The findings reveal distinct empirical frequency bands for enhancing the respective contrasts: 15–38 kHz for conductive materials (copper) and 45–75 kHz for non-conductive materials (acrylic resin). These insights shed light on the frequency-dependent nature of material contrast in EIT images, guiding the selection of empirical operating ranges for various target materials. This research paves the way for improved sensitivity and broader applicability of EIT in diverse areas.


5 June 2025
Verified
Book Chapter
Closed access
PDF file
TNTien Chuong Tran Nguyen
Tien Chuong Tran Nguyen
TDTat Binh Dong
Tat Binh Dong
DNDuc Khang Nguyen
Duc Khang Nguyen
GLGia Khang Ly
Gia Khang Ly
VVViet Thai Le Viet
Viet Thai Le Viet
Trung Nghia TranTrung Nghia Tran
Trung Nghia Tran

1 April 2026 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
DADang Nguyen Ngoc An
Dang Nguyen Ngoc An
Minh Quan Cao DinhMinh Quan Cao Dinh
Minh Quan Cao Dinh
HTHong Thu Nguyen Thi
Hong Thu Nguyen Thi
VDVu nguyen lam duc
Vu nguyen lam duc
We evaluated the indoor environmental quality of the administrative office at University Medical Center Ho Chi Minh City branch 2 and implemented a multi-stage engineering control strategy to optimize occupational health conditions. A cross-sectional assessment monitored important air quality parameters, including carbon dioxide (CO2), fine particulate matter (PM2.5 and PM10), humidity, and illumination. Following baseline measurements, an integrated system was deployed to address pollutant mass balance, consisting of High-Efficiency Particulate Air (HEPA) filtration units for mechanical particle scrubbing, ceiling-mounted axial fans to induce forced convection, and ultraviolet-C germicidal lamps for photochemical disinfection. Post-intervention results demonstrated significant gains in system removal efficiency. CO2 concentrations decreased by over 60% due to enhanced volumetric air exchange, while PM2.5 levels decreased by more than 40% through interception and diffusion mechanisms within the HEPA media. Furthermore, UVC irradiation achieved a 90% reduction in viable airborne microbial colonies. The results of this study show that low-cost, scalable environmental engineering controls and fluid dynamic optimizations effectively mitigate indoor air pollution and enhance workplace stability in healthcare administrative settings.


27 February 2026 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
Minh Quan Cao DinhMinh Quan Cao Dinh
Minh Quan Cao Dinh
HTHai Anh Nguyen Thi
Hai Anh Nguyen Thi
DVDang Khoa Trinh Vo
Dang Khoa Trinh Vo
DLDan Lin Lieu
Dan Lin Lieu
TNTrung Thach Nguyen
Trung Thach Nguyen
HTHong Duyen Trinh Tran
Hong Duyen Trinh Tran
The influence of different voltage measurement and current injection configurations on the quality of image reconstruction in electrical impedance tomography (EIT) was investigated using numerical simulations. Adjacent and opposing techniques were systematically used to examine their effectiveness in voltage acquisition and current delivery. The simulation model employed 16 equally spaced electrodes arranged around a circular domain, with an injected alternating current of 1 mA at a frequency of 50 kHz. A circular object with a conductivity of 0.9 units was sequentially positioned at five distinct locations within the imaging domain, each spaced 0.05 units apart. The reconstructed images were analyzed for positional accuracy and contrast resolution. While each configuration offers specific advantages, they exhibit inherent limitations depending on the application. The results of this study enable the understanding of the trade-offs involved in selecting electrode drive and measurement strategies for optimizing image quality in EIT systems.