A novel assay platform consisting of a microfluidic sliding double-track paper-based chip and a hand-held Raspberry Pi detection system is proposed for determining the albumin-to-creatine ratio (ACR) in human urine. It is a clinically important parameter and can be used for the early detection of related diseases, such as renal insufficiency. In the proposed method, the sliding layer of the microchip is applied and the sample diffuses through two parallel filtration channels to the reaction/detection areas of the microchip to complete the detection reaction, which is a simple method well suited for self-diagnosis of ACR index in human urine. The RGB (red, green, and blue) value intensity signals of the reaction complexes in these two reaction zones are analyzed by a Raspberry Pi computer to derive the ACR value (ALB and CRE concentrations). It is shown that the G + B value intensity signal is linearly related to the ALB and CRE concentrations with the correlation coefficients of R2 = 0.9919 and R2 = 0.9923, respectively. It is additionally shown that the ALB and CRE concentration results determined using the proposed method for 23 urine samples were collected from real suffering chronic kidney disease (CKD) patients are in fine agreement with those acquired operating a traditional high-reliability macroscale method. Overall, for point-of-care (POC) CKD diagnosis and monitoring in clinical applications, the results prove that the proposed method offers a convenient, real time, reliable, and low-spending solution for POC CKD diagnosis.
A microfluidic immuno-biosensor detection system consisting of a microfluidic spectrum chip and a micro-spectrometer detection device is presented for the rapid point-of-care (POC) detection and quantification of high-sensitivity C-reactive protein (hs-CRP) in urine. The detection process utilizes a highly specific enzyme-linked immunosorbent assay (ELISA) method, in which capture antibodies and detection antibodies are pre-deposited on the substrate of the microchip and used to form an immune complex with the target antigen. Horseradish peroxidase (HRP) is added as a marker enzyme, followed by a colorimetric reaction using 3,3′,5,5′-tetramethylbenzidine (TMB). The absorbance values (a.u.) of the colorimetric reaction compounds are measured using a micro-spectrometer device and used to measure the corresponding hs-CRP concentration according to the pre-established calibration curve. It is shown that the hs-CRP concentration can be determined within 50 min. In addition, the system achieves recovery rates of 93.8–106.2% in blind water samples and 94.5–104.6% in artificial urine. The results showed that the CRP detection results of 41 urine samples from patients with chronic kidney disease (CKD) were highly consistent with the conventional homogeneous particle-enhanced turbidimetric immunoassay (PETIA) method’s detection results (R2 = 0.9910). The experimental results showed its applicability in the detection of CRP in both urine and serum. Overall, the results indicate that the current microfluidic ELISA detection system provides an accurate and reliable method for monitoring the hs-CRP concentration in point-of-care applications.
Rheumatoid arthritis (RA) is a chronic autoimmune disorder that causes extensive damage to multiple organs and tissues and has no known cure. This study introduces a microfluidic detection platform that combines a microfluidic reaction chip with a micro-spectrometer to accurately detect the anti-cyclic citrullinated peptide antibody (anti-CCP Ab) biomarker, commonly associated with arthritis. The surface of the microfluidic reaction chip is functionalized using streptavidin to enable the subsequent immobilization of biotinylated-labeled cyclic citrullinated peptide (biotin–CCP) molecules through a streptavidin–biotin reaction. The modified chip is then exposed to anti-CCP Ab, second antibody conjugated with horseradish peroxidase (HRP) (2nd Ab-HRP), 3,3′,5,5′-tetramethylbenzidine (TMB), and a stop solution. Finally, the concentration of the anti-CCP Ab biomarker is determined by analyzing the optical density (OD) of the colorimetric reaction product at 450 nm using a micro-spectrometer. The detection platform demonstrated a strong correlation (R2 = 0.9966) between OD and anti-CCP Ab concentration. This was based on seven control samples with anti-CCP Ab concentrations ranging from 0.625 to 100 ng/mL. Moreover, for 30 artificial serum samples with unknown anti-CCP Ab concentrations, the biosensor achieves a correlation coefficient of (R2 = 0.9650). The proposed microfluidic detection platform offers a fast and effective method for accurately identifying and quantifying the anti-CCP Ab biomarker. Thus, it offers a valuable tool for the early diagnosis and monitoring of RA and its progression in point-of-care settings.
Electrokinetics has established itself as a central pillar in microfluidic research, offering a powerful, non-mechanical means to manipulate fluids and analytes. Mechanisms such as electroosmotic flow (EOF), electrophoresis (EP), and dielectrophoresis (DEP) re-main central to the field, once more layers of complexity emerge heterogeneous interfaces, viscoelastic liquids, or anisotropic droplets are introduced. Five research directions have become prominent. Field-driven manipulation of droplets and emulsions—most strikingly Janus droplets—demonstrates how asymmetric interfacial structures generate unconventional transport modes. Electrokinetic injection techniques follow as a second focus, because sharply defined sample plugs are essential for high-resolution separations and for maintaining analytical accuracy. Control of EOF is then framed as an integrated design challenge that involves tuning surface chemistry, engineering zeta potential, implementing nanoscale patterning, and navigating non-Newtonian flow behavior. Next, electrokinetic instabilities and electrically driven micromixing are examined through the lens of vortex-mediated perturbations that break diffusion limits in low-Reynolds-number flows. Finally, electrokinetic enrichment strategies—ranging from ion concentration polarization focusing to stacking-based preconcentration—demonstrate how trace analytes can be selectively accumulated to achieve detection sensitivity. Ultimately, electrokinetics is converging towards sophisticated integrated platforms and hybrid powering schemes, promising to expand microfluidic capabilities into previously inaccessible domains for analytical chemistry and diagnostics.
A microfluidic distillation system is proposed to facilitate the separation and subsequent determination of propionic acid (PA) in foods. The system comprises two main components: (1) a polymethyl methacrylate (PMMA) micro-distillation chip incorporating a micro-evaporator chamber, a sample reservoir, and a serpentine micro-condensation channel; and (2) and a DC-powered distillation module with built-in heating and cooling functions. In the distillation process, homogenized PA sample and de-ionized water are injected into the sample reservoir and micro-evaporator chamber, respectively, and the chip is then mounted on a side of the distillation module. The de-ionized water is heated by the distillation module, and the steam flows from the evaporation chamber to the sample reservoir, where it prompts the formation of PA vapor. The vapor flows through the serpentine microchannel and is condensed under the cooling effects of the distillation module to produce a PA extract solution. A small quantity of the extract is transferred to a macroscale HPLC and photodiode array (PDA) detector system, where the PA concentration is determined using a chromatographic method. The experimental results show that the microfluidic distillation system achieves a distillation (separation) efficiency of around 97% after 15 min. Moreover, in tests performed using 10 commercial baked food samples, the system achieves a limit of detection of 50 mg/L and a limit of quantitation of 96 mg/L, respectively. The practical feasibility of the proposed system is thus confirmed.
A microfluidic system for detecting sodium ions (Na+) has been developed, incorporating a micro finger-pump chip and a micro-spectrometer platform to measure Na+ concentration in human serum. A small volume (10 μL) of serum sample is introduced into the microchip and reacted with a preloaded reagent mixture through a two-step finger-pump actuation process. The resulting purple complex is directed into the detection area of the chip and analyzed using the micro-spectrometer at wavelengths of 555 and 666 nm. The Na+ concentration is then inversely derived from the measured A555/A666 absorbance ratio using self-written software installed on a Raspberry Pi. The entire detection process is completed in just 3 min, offering a significant advantage in meeting clinical needs compared to the traditional reporting turnaround time of several hours in medical institutions. The experimental results indicate a linear relationship between the measured absorbance ratio and Na+ concentration within the range of 1–200 mM, with a correlation coefficient of R2 = 0.9989. Additionally, the detection results from 60 serum samples collected from chronic kidney disease (CKD) patients showed a strong agreement with those obtained using the conventional indirect ion-selective electrode (ISE) method, achieving a correlation coefficient of R2 = 0.9885 and an average recovery rate of 99.4%. In summary, the proposed system provides a practical, affordable, and rapid alternative to conventional Na+ detection methods, making it highly promising for point-of-care (POC) testing applications.