Hugo Mesquita Vasconcelos

Mr. Hugo Mesquita Vasconcelos

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
HVHugo Mesquita Vasconcelos
Hugo Mesquita Vasconcelos
Pedro José SousaPedro José Sousa
Pedro José Sousa
SDSusana Dias
Susana Dias
JPJosé P. Pinto
José P. Pinto
IGIlmer Diederd van Golde
Ilmer Diederd van Golde
PMPedro Moreira
Pedro Moreira
Wide-area maritime surveillance is an increasingly important focus for countries with large Exclusive Economic Zones (EEZ), such as Portugal, which are responsible for monitoring and protecting these zones and their resources. Passive acoustic autonomous buoy networks equipped with hydrophones are a promising approach for wide-area maritime surveillance. However, achieving a discrete, low-cost system introduces many technical challenges. This work describes a practical, low-power, two-state architecture that separates continuous ship detection from detailed vessel class classification. First, an always-on microcontroller performs continuous binary ship presence detection and triggers the higher-power classifier only when a vessel is detected. The high-accuracy acoustic classifier was tested across embedded controllers to identify the minimum platform capable of sustaining its intended 1 Hz classification rate. A Raspberry Pi 5 achieved the 1 s target with a measured continuous consumption of 4 W; however, adding sensing, storage, and communications is expected to raise the always-on consumption to around 5 W. If this node was used by itself, a week-long autonomy requirement, therefore, would imply 840 Wh of usable energy storage, and recovering this deficit rapidly under limited insolation would require several hundred watts of photovoltaic capacity, driving both buoy volume and cost up. To address this, an always-on edge node based on an ESP32-S3 microcontroller was implemented, running a lightweight binary detection of a vessel presence model trained in Edge Impulse using a subset of Ocean Networks Canada recordings. The edge node consumes 0.69 W continuously and is intended to trigger a wake-up line to power the higher-performance node only when a ship is detected, reducing average energy demand while maintaining the ability to run a richer classifier on demand. The presented architecture, profiling workflow, and energy calculations provide a path to power-aware passive acoustic monitoring systems suitable for extended maritime deployments.

7 January 2025 in Fluids
Verified
Journal Article
Open access
PDF file
ASAlexandre Brás dos Santos
Alexandre Brás dos Santos
HVHugo Mesquita Vasconcelos
Hugo Mesquita Vasconcelos
TDTiago M. R. M. Domingues
Tiago M. R. M. Domingues
Pedro José SousaPedro José Sousa
Pedro José Sousa
SDSusana Dias
Susana Dias
PMPedro Moreira
Pedro Moreira
This study focuses on the development of a machine learning (ML) model to elaborate on predictions of structural damage in submerged structures due to ocean states and subsequently compares it to a real-life case of a 6-month experiment with a benthic lander bearing a multitude of sensors. The ML model uses wave parameters such as height, period and direction as input layers, which describe the ocean conditions, and strains in selected points of the lander structure as output layers. To streamline the dataset generation, a simplified approach was adopted, integrating analytical formulations based on Morison equations and numerical simulations through the Finite Element Method (FEM) of the designed lander. Subsequent validation involved Fluid–Structure Interaction (FSI) simulations, using a 2D Computational Fluid Dynamics (CFD)-based numerical wave tank of the entire ocean depth to access velocity profiles, and a restricted 3D CFD model incorporating the lander structure. A case study was conducted to empirically validate the simulated ML model, with the design and deployment of a benthic lander at 30 m depth. The lander was monitored using electrical and optical strain gauges. The strains measured during the testing period will provide empirical validation and may be used for extensive training of a more reliable model.

10 February 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
HVHugo Mesquita Vasconcelos
Hugo Mesquita Vasconcelos
DADaniela Azevedo
Daniela Azevedo
Rodrigo Baptista ValenteRodrigo Baptista Valente
Rodrigo Baptista Valente
Pedro José SousaPedro José Sousa
Pedro José Sousa
TDTiago M. R. M. Domingues
Tiago M. R. M. Domingues
PMPedro Moreira
Pedro Moreira
Degraded mechanical properties in the aortic wall can lead to the formation of aortic aneurysms, potentially resulting in life-threatening ruptures. Current diagnostic criteria using maximum aortic diameter often fail to predict this critical moment, underscoring the need for more accurate patient-based prediction methods. A hospital-compatible experimental apparatus was designed for quasi-static ex vivo inflation testing of intact Ascending Thoracic Aortic Aneurysm (ATAA) specimens with 360° full-field three-dimensional digital image correlation (3D-DIC). Given hospital handling constraints, liquid pressurization was not feasible; instead, pressure was applied via a balloon-driven pneumatic system, and synchronized stereo imaging was used to measure surface displacement fields between 80 and 120 mmHg. The system was validated using a CT-derived ATAA silicone phantom. Full-field displacement measurements showed close agreement with finite element simulations, supporting the mechanical reliability of the apparatus and the repeatability of the measurement workflow. In addition, a frozen–thawed healthy porcine thoracic aorta was tested to demonstrate biological feasibility, particularly regarding the speckle application and DIC tracking, without aiming to extract tissue constitutive parameters. Overall, the setup provides a practical framework for acquiring full-field inflation-induced deformation data from intact aortic specimens in a hospital setting, enabling future studies on resected human ATAA tissue and model calibration that may contribute to more accurate methods for rupture prediction.