Hyobong Hong

Dr. Hyobong Hong


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2011 in Journal of Immunological Methods
Verified
Journal Article
Closed access
HHHyobong Hong
Hyobong Hong
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
KSKi-Bong Song
Ki-Bong Song
CCChel-Jong Choi
Chel-Jong Choi
MCMyung-Ae Chung
Myung-Ae Chung
AOAndreas Offenhäusser
Andreas Offenhäusser

1 September 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
CKChang-Beom Kim
Chang-Beom Kim
ELEul-Gyoon Lim
Eul-Gyoon Lim
SSSung Woong Shin
Sung Woong Shin
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
HHHyobong Hong
Hyobong Hong

13 December 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
CKChang-Beom Kim
Chang-Beom Kim
SPSang-Jin Park
Sang-Jin Park
JJJae-Chan Jeong
Jae-Chan Jeong
SCSeung-Min Choi
Seung-Min Choi
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
HHHyobong Hong
Hyobong Hong
Occlusion of the major cerebral artery usually results in brain hypoxic-ischemic injury, which evokes neuroinflammation and microglial activation. Activated microglia are considered a source of multiple neurotoxic factors, such as reactive oxygen species (ROS), in the central nervous system (CNS). We herein present a 3D-rendering brain imaging technique in an experimental rodent model of cerebral ischemia based on 2D magnetic images of superparamagnetic iron oxide nanoparticles (SPIONs) using the planar frequency mixing magnetic detection (p-FMMD) technique. A rat model of cerebral ischemia was established by unilateral middle cerebral artery occlusion with reperfusion (MCAO/R) injury. 2,3,5-Triphenyltetrazolium chloride (TTC) staining was performed to demonstrate the irreversibly damaged ischemic brain tissues, and double immunofluorescent labeling of OX6 (activated microglial marker) and ethidium (ROS marker) was conducted to confirm ROS generation in the activated microglia in the infarcted brain region. The ischemic brain sections treated with OX6-conjugated SPIONs were scanned using our p-FMMD system, yielding 2D images on the basis of the nonlinear magnetic characteristics inherent in SPIONs. The p-FMMD signal images representing microglia activation show an infarct ratio of 44.6 ± 7.1% compared to the contralateral counterpart, which is smaller than observed by TTC (60.9 ± 4.9%) or magnetic resonance imaging (MRI, 65.7 ± 2.7%). Furthermore, we developed a 3D-rendering brain imaging process based on the 2D p-FMMD signal images. The 3D reconstructed model showed a decreased ratio of coincidence of the ischemic regions compared with MRI models. In this study, we successfully conducted a feasibility test on whether our p-FMMD technology, a technique for signaling and imaging based on the nonlinearity of SPIONs, can be used to visualize the ischemic brain region in real time by detecting activated microglia in an MCAO/R animal model. Therefore, our method might allow for a different approach to analyze the pathophysiology of ischemic stroke through molecular imaging. Furthermore, we propose that this magnetic particle imaging (MPI) technique that detects the nonlinear magnetization properties of SPIONs could be applied not only to a stroke model but also to various types of pathophysiological studies as a new bioimaging tool.

21 July 2014 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
HHHyobong Hong
Hyobong Hong
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
INI. H. Nam
I. H. Nam
CCC. J. Choi
C. J. Choi
SSS. W. Shin
S. W. Shin
A novel analytical system is presented that employs two different types of magnetic particles (MPs) with frequency mixing magnetic detection (FMMD).

31 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
TKTae Yi Kim
Tae Yi Kim
JJJae-chan Jeong
Jae-chan Jeong
BSBeom-Su Seo
Beom-Su Seo
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
HHHyobong Hong
Hyobong Hong
In this study, we propose an efficient field-free line (FFL) generator for mechanically driven FFL magnetic particle imaging (MPI) applications. The novel FFL generator comprises pairs of Halbach arrays and bar magnets. The proposed design generates high-gradient FFLs with low-mass permanent magnets, realizing fine spatial resolutions in MPI. We investigate the magnetic field generated using simulations and experiments. Our results show that the FFL generator yields a high gradient of 4.76 T/m at a cylindrical field of view of 30 mm diameter and a 70 mm open bore. A spatial resolution of less than 3.5 mm was obtained in the mechanically driven FFL-MPI.

10 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JJJae-chan Jeong
Jae-chan Jeong
TKTae Yi Kim
Tae Yi Kim
HCHyeon Sung Cho
Hyeon Sung Cho
BSBeom-Su Seo
Beom-Su Seo
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
HHHyobong Hong
Hyobong Hong
We present two magnetic particle imaging (MPI) systems with bore sizes of 75 mm and 100 mm, respectively, using three-dimensionally arranged permanent magnets for excitation and frequency mixing magnetic detection (FMMD) coils for detection. A rotational and a translational stage were combined to move the field free line (FFL) and acquire the MPI signal, thereby enabling simultaneous overall translation and rotational movement. With this concept, the complex coil system used in many MPI systems, with its high energy consumption to generate the drive field, can be replaced. The characteristic signal of superparamagnetic iron oxide (SPIO) nanoparticles was generated via movement of the FFL and acquired using the FMMD coil. The positions of the stages and the occurrence of the f1 + 2f2 harmonics were mapped to reconstruct the spatial location of the SPIO. Image reconstruction was performed using Radon and inverse Radon transformations. As a result, the presented method based on mechanical movement of permanent magnets can be used to measure the MPI, even for samples as large as 100 mm. Our research could pave the way for further technological developments to make the equipment human size, which is one of the ultimate goals of MPI.