Beom-Su Seo

Mr. Beom-Su Seo

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015
Verified
Book Chapter
Closed access
PDF file
JBJaemin Byun
Jaemin Byun
KNKi-In Na
Ki-In Na
BSBeom-Su Seo
Beom-Su Seo
MRMyungchan Roh
Myungchan Roh

1 June 2015 in ETRI Journal
Verified
Journal Article
Closed access
PDF file
JBJaemin Byun
Jaemin Byun
BSBeom-Su Seo
Beom-Su Seo
JLJihong Lee
Jihong Lee

31 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
TKTae Yi Kim
Tae Yi Kim
JJJae-chan Jeong
Jae-chan Jeong
BSBeom-Su Seo
Beom-Su Seo
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
HHHyobong Hong
Hyobong Hong
In this study, we propose an efficient field-free line (FFL) generator for mechanically driven FFL magnetic particle imaging (MPI) applications. The novel FFL generator comprises pairs of Halbach arrays and bar magnets. The proposed design generates high-gradient FFLs with low-mass permanent magnets, realizing fine spatial resolutions in MPI. We investigate the magnetic field generated using simulations and experiments. Our results show that the FFL generator yields a high gradient of 4.76 T/m at a cylindrical field of view of 30 mm diameter and a 70 mm open bore. A spatial resolution of less than 3.5 mm was obtained in the mechanically driven FFL-MPI.

10 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JJJae-chan Jeong
Jae-chan Jeong
TKTae Yi Kim
Tae Yi Kim
HCHyeon Sung Cho
Hyeon Sung Cho
BSBeom-Su Seo
Beom-Su Seo
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
HHHyobong Hong
Hyobong Hong
We present two magnetic particle imaging (MPI) systems with bore sizes of 75 mm and 100 mm, respectively, using three-dimensionally arranged permanent magnets for excitation and frequency mixing magnetic detection (FMMD) coils for detection. A rotational and a translational stage were combined to move the field free line (FFL) and acquire the MPI signal, thereby enabling simultaneous overall translation and rotational movement. With this concept, the complex coil system used in many MPI systems, with its high energy consumption to generate the drive field, can be replaced. The characteristic signal of superparamagnetic iron oxide (SPIO) nanoparticles was generated via movement of the FFL and acquired using the FMMD coil. The positions of the stages and the occurrence of the f1 + 2f2 harmonics were mapped to reconstruct the spatial location of the SPIO. Image reconstruction was performed using Radon and inverse Radon transformations. As a result, the presented method based on mechanical movement of permanent magnets can be used to measure the MPI, even for samples as large as 100 mm. Our research could pave the way for further technological developments to make the equipment human size, which is one of the ultimate goals of MPI.

18 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
BSBeom-Su Seo
Beom-Su Seo
BPByungjae Park
Byungjae Park
HCHoon Choi
Hoon Choi
This paper proposes a method to extend a sensing range of a short-baseline stereo camera (SBSC). The proposed method combines a stereo depth and a monocular depth estimated by a convolutional neural network-based monocular depth estimation (MDE). To combine a stereo depth and a monocular depth, the proposed method estimates a scale factor of a monocular depth using stereo depth–mono depth pairs and then combines the two depths. Another advantage of the proposed method is that the trained MDE model may be utilized for different environments without retraining. The performance of the proposed method is verified qualitatively and quantitatively using the directly collected and open datasets.

1 February 2018
Verified
Conference Paper
Closed access
MAMarcella Astrid
Marcella Astrid
SLSeung-Ik Lee
Seung-Ik Lee
BSBeom-Su Seo
Beom-Su Seo