Hyung-Sik Kim

Prof. Dr. Hyung-Sik Kim

Konkuk University
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2014 in BMC Neuroscience
Verified
Journal Article
Open access
PDF file
YCYoon Gi Chung
Yoon Gi Chung
SHSang Woo Han
Sang Woo Han
HKHyung-Sik Kim
Hyung-Sik Kim
SCSoon-Cheol Chung
Soon-Cheol Chung
JPJang-Yeon Park
Jang-Yeon Park
Sung-Phil KimSung-Phil Kim
Sung-Phil Kim
Slow-adapting type I (SA-I) afferents deliver sensory signals to the somatosensory cortex during low-frequency (or static) mechanical stimulation. It has been reported that the somatosensory projection from SA-I afferents is effective and reliable for object grasping and manipulation. Despite a large number of neuroimaging studies on cortical activation responding to tactile stimuli mediated by SA-I afferents, how sensory information of such tactile stimuli flows over the somatosensory cortex remains poorly understood. In this study, we investigated tactile information processing of pressure stimuli between the primary (SI) and secondary (SII) somatosensory cortices by measuring effective connectivity using dynamic causal modeling (DCM). We applied pressure stimuli for 3 s to the right index fingertip of healthy participants and acquired functional magnetic resonance imaging (fMRI) data using a 3T MRI system.

29 October 2015 in BMC Neuroscience
Verified
Journal Article
Open access
PDF file
YCYoon Gi Chung
Yoon Gi Chung
SHSang Woo Han
Sang Woo Han
HKHyung-Sik Kim
Hyung-Sik Kim
SCSoon-Cheol Chung
Soon-Cheol Chung
JPJang-Yeon Park
Jang-Yeon Park
Sung-Phil KimSung-Phil Kim
Sung-Phil Kim
Tactile adaptation is a phenomenon of the sensory system that results in temporal desensitization after an exposure to sustained or repetitive tactile stimuli. Previous studies reported psychophysical and physiological adaptation where perceived intensity and mechanoreceptive afferent signals exponentially decreased during tactile adaptation. Along with these studies, we hypothesized that somatosensory cortical activity in the human brain also exponentially decreased during tactile adaptation. The present neuroimaging study specifically investigated temporal changes in the human cortical responses to sustained pressure stimuli mediated by slow-adapting type I afferents. We applied pressure stimulation for up to 15 s to the right index fingertip in 21 healthy participants and acquired functional magnetic resonance imaging (fMRI) data using a 3T MRI system. We analyzed cortical responses in terms of the degrees of cortical activation and inter-regional connectivity during sustained pressure stimulation. Our results revealed that the degrees of activation in the contralateral primary and secondary somatosensory cortices exponentially decreased over time and that intra- and inter-hemispheric inter-regional functional connectivity over the regions associated with tactile perception also linearly decreased or increased over time, during pressure stimulation. These results indicate that cortical activity dynamically adapts to sustained pressure stimulation mediated by SA-I afferents, involving changes in the degrees of activation on the cortical regions for tactile perception as well as in inter-regional functional connectivity among them. We speculate that these adaptive cortical activity may represent an efficient cortical processing of tactile information.

25 April 2017 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
MCMi-Hyun Choi
Mi-Hyun Choi
BKBoseong Kim
Boseong Kim
HKHyung-Sik Kim
Hyung-Sik Kim
SGSeon-Young Gim
Seon-Young Gim
WKWoo-Ram Kim
Woo-Ram Kim
SCSoon-Cheol Chung
Soon-Cheol Chung
This study was conducted to identify characteristics of the perceptual threshold level and EEG responses to vibrotactile stimulations at various high frequencies, and to examine the possibility of distinguishing vibrotactile stimulations by frequency through such response characteristics. The vibrotactile stimulations of six frequencies (150, 200, 225, 250, 275, and 300 Hz) were exerted on the first joint of right index finger. The perceptual threshold level was defined as the first minimum perceived intensity when the intensity stimulation was exerted step by step at each vibration frequency. EEG response characteristics were investigated by examining a single index corresponding to the peak or area of event-related desynchronization/synchronization (ERD/ERS) and seven specific indices derived by combining the single ERD/ERS indices. There was a significant difference in the perceptual threshold level across different frequencies. Specifically, the differences in vibration stimulus between 150 Hz and 200 Hz, and between 150 Hz and 225 Hz were significant. Of the EEG response characteristics, the single index of the peak or area of ERD/ERS did not show a significant difference by frequency. However, (ERS-ERD), ERD×(ERS-ERD), and ERS×(ERS-ERD) showed a significant difference between vibration stimulations at 150 Hz and 200 Hz, and between vibration stimulations at 150 Hz and 225 Hz, among the specific indices combined using the peak values of ERD/ERS. Furthermore, ERS×(ERS-ERD) showed a significant difference between 150 Hz and 225 Hz, and between 225 Hz and 275 Hz among the specific indices combined using the area of ERD/ERS. The perceptual threshold level and the specific indices of ERD/ERS suggested in the present study can be used as quantitative measurement indices to distinguish high-frequency vibration stimulation.

20 February 2015 in Journal of Physiological Anthropology
Verified
Journal Article
Open access
PDF file
HKHyung-Sik Kim
Hyung-Sik Kim
MCMi-Hyun Choi
Mi-Hyun Choi
JBJi-Hye Baek
Ji-Hye Baek
SPSung-Jun Park
Sung-Jun Park
JLJung-Chul Lee
Jung-Chul Lee
SCSoon-Cheol Chung
Soon-Cheol Chung
The present study addressed how 92% oxygen administration affects cognitive performance, blood oxygen saturation (SpO2), and heart rate (HR) of intellectually and developmentally disabled people. Seven males (28.9 ± 1.8 years) and seven females (34.4 ± 8.3 years) with intellectual and developmental disabilities (disabled level 2.1 ± 0.5) completed an experiment consisting a 0-back task with normal air (21% oxygen) administered in one run and hyperoxic air (92% oxygen) administered in the other run. The experimental sequence in each run consisted of a 1-min adaptation phase, 2-min control phase, and 2-min 0-back task phase, where SpO2 and HR were gauged for each phase. The administration of 92% oxygen increased 0-back task performance of intellectually and developmentally disabled people, in association with increased SpO2 and decreased HR. Our results demonstrate that sufficient oxygen supply subserving cognitive functions, even as a short-term effect, could increase cognitive ability for the intellectually and developmentally disabled people. It is concluded that enriched oxygen can positively affect, at least in the short-term, the working memory of those with intellectual and developmental disability.

22 April 2023 in Behavioral Sciences
Verified
Journal Article
Open access
PDF file
MCMi-Hyun Choi
Mi-Hyun Choi
KKKyu-Beom Kim
Kyu-Beom Kim
YKYe-Jin Kim
Ye-Jin Kim
JKJi-Su Kim
Ji-Su Kim
HKHyung-Sik Kim
Hyung-Sik Kim
SCSoon-Cheol Chung
Soon-Cheol Chung
The purpose of this study is to analyze the cognitive characteristics that can be induced by vibration stimuli at two intensities, three frequencies, and five presentation periods. The experiment was conducted on 20 right-handed adult males, and a subjective evaluation was performed using a questionnaire. Regression analysis was performed to observe the parameters affecting cognitive characteristics according to changes in intensity, frequency, and stimulation duration. The regression analysis results showed that the cognitive characteristics affected by changes in intensity, frequency, and stimulation duration were “heavy”, “bold”, “thick”, and “light”. The cognitive characteristics affected by two-variable combinations were “deep”, “clear”, “vibrating”, “dense”, “numb”, “blunt”, “shallow”, “fuzzy”, and “soft”. Cognitive characteristics affected by either intensity, frequency, or stimulation duration were “fast”, “pungent”, “skinny”, “thin”, “slow”, “ticklish”, “tingling”, “prickling”, “tap”, and “rugged”. By observing the cognitive characteristics that can be induced by the combination of intensity, frequency, and stimulation duration, we confirmed that in addition to intensity and frequency, the stimulation duration is an important factor that influences the induction of various cognitive characteristics. The results presented in the study can be used to enhance the utility of haptic surfaces for extended reality applications.

3 July 2023 in Electronics
Verified
Journal Article
Open access
PDF file
KKKi-Han Kim
Ki-Han Kim
JAJinsu An
Jinsu An
YPYoung-Jin Park
Young-Jin Park
Jung-Hoon ParkJung-Hoon Park
Jung-Hoon Park
HKHong Bae Kim
Hong Bae Kim
HKHyung-Sik Kim
Hyung-Sik Kim
Thermal tissue ablation may damage surrounding healthy tissue and cause pain. In this study, tissue ablation with the sequential application of electrical energy-inducing irreversible electroporation (IRE) and electrolysis (EL) (IRE + EL = IREEL) was investigated. An IREEL device was designed to control five output pulse parameters: voltage level (VL), pulse width (PW), pulse interval (PI), pulse number (PN), and pulse tail time (PTT). IREEL experiments were conducted on vegetable tissue. The results indicated that by increasing the VL and PTT, the ablation area increased, whereas the impedance was reduced significantly. Almost no ablation area was observed when only EL or IRE at 500 V and 1000 V, respectively, were applied. The ablation area observed with IRE alone at 1500 V was defined as 100%. In the case of IREEL at 500 V and 1000 V, ablation was induced even with the use of micro-second level PTT, and ablation areas of 91% and 186% were achieved, respectively. For IREEL at a voltage of 1500 V, the ablation area expanded to 209% and the maximum temperature was 48.7 °C, whereas the temperature did not exceed 30 °C under other conditions. A change in pH was also observed in an agar-gel phantom experiment which was conducted to examine and confirm whether IREEL induced electrolysis. IREEL was able induce ablation at low voltages owing to the synergistic effect of applying IRE and EL sequentially. Moreover, the ablation areas at high voltages could be increased compared to the areas observed when IRE and EL were applied independently.